1. Catalogs
  2. SCHAKO KG
  3. DISA-H (2025)

DISA-H (2025)

DISA-H (2025)
1 / 34 PagesView full catalog

DISA-H (2025)

Product catalog summary
Induction Diffuser DISA-H Overview
The DISA-H induction diffuser combines air diffuser flow characteristics with water-based heat exchangers to efficiently manage thermal loads while maintaining low air exchange rates. It is suitable for installation in suspended ceilings in environments such as hotels, hospitals, and offices. The diffuser is available in three nozzle configurations and lengths of 900, 1200, and 1500 mm, with ventilation grilles ordered separately.
Advantages
  • High energy efficiency and performance
  • Compact dimensions
  • Reduced primary air usage
  • Low noise levels
  • Minimal installation and maintenance requirements
Functionality
The diffuser uses primary air to induce secondary room air, which is then cooled or heated via a water register. The mixed air is supplied at low velocity, ensuring efficient thermal load compensation.
Construction and Models
  • Galvanized sheet steel housing with optional painted finish
  • Available in 2-pipe or 4-pipe systems
  • Nozzle configurations for small, medium, and large air volumes
  • Accessories include rubber lip seals, flexible hoses, and various louvre grids
Technical Data
Performance data includes cooling capacities for different configurations and lengths, with detailed specifications for primary and secondary air flows, cooling capacities, and pressure drops.
Control Units
  • Valves and actuators for temperature control
  • Condensation monitors to prevent dew point issues
Assembly and Maintenance
Includes guidelines for installation and maintenance to ensure optimal performance and longevity of the diffuser.
Specifications
The document outlines the cooling and heating capacities of the DISA-H diffuser, with data on primary air and water capacities, pressure drops, and temperature differences. The diffuser is available in different sizes (900, 1200, and 1500 mm) and configurations (cooling and heating).
Cooling and Heating Capacities
Tables provide detailed data on the cooling and heating capacities for various air and water flow rates, pressure drops, and temperature differences. The data is segmented by diffuser size and configuration.
Sound Levels
The document includes sound pressure levels for different configurations, indicating the diffuser's noise performance under various conditions.
Correction Factors
Correction factors for critical throw, jet path, and maximum end velocity are provided for different blade positions and grille types. These factors are essential for adjusting performance based on specific installation conditions.
Construction and Version Information
The document notes that construction is subject to change and provides version details for the DISA-H diffuser models.
Key Parameters
  • Cooling and heating capacities are provided in watts for different flow rates and pressure drops.
  • Sound levels are specified in decibels (dB(A)).
  • Correction factors are given for various blade positions and grille configurations.
Recommendations
The document suggests using the correction factors to adjust the diffuser's performance based on specific installation and operational conditions.
Induction Diffuser Specifications
The document outlines the specifications and configurations for the DISA-H induction diffuser series, including models with and without grilles. Key parameters include blade positions (straight, 44° diverging, 84° diverging) and correction factors for critical throw and maximum end velocity of the jet, both isothermal and with Coanda effect.
Water Flow and Correction Factors
Tables provide data on water temperature differences (ΔT), flow rates (l/h), and correction factors for TV and I diagrams. These factors are crucial for adjusting the performance of the diffusers under varying conditions.
Valve and Actuator Specifications
The document details the specifications for 3-way and 2-way valves, including nominal diameters, connection types, and kvs values. Actuators compatible with these valves are specified, with details on operating voltage, activation types, and connection diagrams.
Control Units and Thermostats
Control units like RCU 10 and RCU 15 are described, highlighting their operating modes, control signals, and connection diagrams. Room thermostats such as RAA41 and RDG are also covered, with features like manual switches, display options, and automatic mode switching.
Condensation Monitoring
Models QXA2602, QXA2604, QXA2601, and QXA2603 are discussed for their role in detecting relative humidity near the dew point. The document explains the mode of action and the impact of relay contact changes on cooling systems.
Specifications
The document outlines the specifications for wiring diagrams QXA2601, QXA2602, QXA2603, and QXA2604. These systems operate on AC/DC 24 V or AC 230 V and feature potential-free changeover contacts for various voltage ranges. They are designed for quick installation and come with integrated or remote sensors and a two-color LED status display.
Procedures
1. Cooling capacity is managed by valve position or controller until the condensation signal ceases.
2. Water supply temperature is adjusted by a selectable value and gradually returned to normal once the signal disappears.
Norms and Recommendations
Strain relief for AC 230 V terminals is necessary, and cables should be secured with cable binders.
Induction Diffuser DISA-H
The DISA-H series is designed for horizontal installation in suspended ceilings, suitable for hotels, hospitals, and offices. It features easy maintenance with components like grille and plenum box cleaned using compressed air. The diffuser is available in various configurations for different air volumes and includes a heat exchanger for cooling or heating.
Technical Parameters
Key parameters include primary air flow, static pressure, water-side pressure loss, and sound pressure level. The document provides detailed measurements and configurations for installation and operation.
Order Details
Includes options for system type (2-pipe or 4-pipe), nozzle configuration, length, water connection, and additional accessories like valves, actuators, and grilles. The document specifies product details for SCHAKO type DISA-H with various customization options.
See more

Catalog excerpts

DISA-H (2025)-2

11/15 - 2 Construction subject to change. Version: 14.12.2015 No return possible!

 Open the catalog to page 2
DISA-H (2025)-3

Induction diffuser DISA-H Description Induction diffusers combine the flow characteristics of air diffusers with the energetic advantages of load discharge via water-based heat exchangers, allowing them to remove high thermal loads from the room while keeping the hygienically required air exchange low. Its low installation depth and horizontal air flow makes it suitable in particular for installation in suspended entrance halls and in suspended ceiling panellings, such as in hotels, hospitals and offices. The primary air (1) supplied from the plenum box induces secondary air in the room (2),...

 Open the catalog to page 3
DISA-H (2025)-4

Model DISA-H DISA-H-H DISA-H-HT DISA-...-D DISA-...-E DISA-...-F DISA-...- 900 DISA-...-1200 DISA-...-1500 Induction diffuser DISA-H Description of the equipment Construction Housing and nozzle plate - Galvanised sheet steel, with 1 or 2 connection pipes 098, 0123 (standard) or 0148 mm. Painted housing RAL 9005 (optional) - Connection pipe position: - horizontal (-H) - Arrangement of connecting pieces - 1 central connecting piece (-AS1) - 2 central connecting pieces and at the same distance (-AS2/AS3) Heat exchanger - 2-pipe system (cooling or heating) or optionally 4-pipe system (cooling and...

 Open the catalog to page 4
DISA-H (2025)-5

ICHAK#Induction diffuser DISA-H Models and dimensions Dimensions and weights 1 Housing 2 Heat exchanger 3 Supply air inlet L (mm) = Length (900 ,1200 and 1500) 4 Water connection 0D (mm) = diameter of the connection pipes (98, 123 and 148) 1) Standard unit: housing + heat exchanger (empty) Construction subject to change.

 Open the catalog to page 5
DISA-H (2025)-6

ICHAKOInduction diffuser DISA-H Arrangement of the connection pieces and water connection Number of connecting pieces with 1 connecting piece (-AS1) Number/position of the connection pipes - 1 connection pipe (standard) - centre back (-AS1) - 2 connection pipes - left and right back (-AS3/-AS2) Number/position of the water connections - with 2 water connections (2-pipe system, standard) - with 4 water connections (4-pipe system) - left back (-WS1) - right back (-WS2) Hydraulic connections DISA-H-H (2-pipe) with 2 connecting pieces (-AS2/AS3) Hydraulic connections DISA-H-HT (4-pipe) Construction...

 Open the catalog to page 6
DISA-H (2025)-7

The grilles are mounted with concealed mounting VM11. Accessories Rubber lip seal (-GD) At the connection piece for better tightness. Volumetric flow measuring tube (-MR) The supplied primary volumetric flow can be simply checked by checking the static pressure with a Pa meter. The measurement is taken in the supply air area. Flexible connection hoses (-FA) Flexible armoured hose with stainless steel braid, oxygen diffusion layer to DIN 4726, one-sided by means of plug-in fitting 90° with stainless steel prong, support ring, 2 sealing rings (operating pressure 20 bar, test pressure 60 bar, temperature...

 Open the catalog to page 7
DISA-H (2025)-8

Induction diffuser DISA-HTechnical data Performance data DISA-H-H -...-D -Cooling- L (mm)

 Open the catalog to page 8
DISA-H (2025)-9

Induction diffuser DISA-HDISA-H-H -...-E -Cooling- L (mm)

 Open the catalog to page 9
DISA-H (2025)-10

Induction diffuser DISA-HDISA-H-H -...-F -Cooling- L (mm) Construction subject to change.

 Open the catalog to page 10
DISA-H (2025)-11

Induction diffuser DISA-HDISA-H-H -...-D -Heating- L (mm) Construction subject to change.

 Open the catalog to page 11
DISA-H (2025)-12

Induction diffuser DISA-HDISA-H-H -...-E -Heating- L (mm) Construction subject to change.

 Open the catalog to page 12
DISA-H (2025)-13

Induction diffuser DISA-HDISA-H-H -...-F -Heating- L (mm) Construction subject to change.

 Open the catalog to page 13
DISA-H (2025)-14

Induction diffuser DISA-H Sound level Sound pressure level (room damping -8 dB)11/15 - 14 Version: 14.12.2015 L (mm) Construction subject to change.

 Open the catalog to page 14
DISA-H (2025)-15

“HAk#Induction diffuser DISA-HFlow data DISA-H-D (with grille) Critical throw Maximum end velocity of jet (isotherm) with coanda effect Correction factors for the critical throw Length correction factors for air volumes Critical jet path - Correction factors for PA grille Maximum end velocity of jet - Correction factors for PA grille PA-1 Blade position straight PA-1 Blade position straight Critical jet path - Correction factors for IB grille Maximum end velocity of jet - Correction factors for IB grille IB-1 Blade position straight IB-1 Blade position straight Version: 14.12.2015 Construction...

 Open the catalog to page 15
DISA-H (2025)-16

Induction diffuser DISA-H Maximum end velocity of jet (isothermal) at floor level Temperature ratio / induction ratio secondary slot - primary air only Correction factors for temperature ratios TV and Induction ratio Length correction factors for air volumes Maximum end velocity of jet - Correction factors for PA grille Induction ratios and temperature ratios -Correction factors for PA grille PA-1 Blade position straight Maximum end velocity of jet - Correction factors for IB grille PA-1 Blade position straight IB-1 Blade position straight Induction ratios and temperature ratios -Correction factors...

 Open the catalog to page 16
DISA-H (2025)-17

“HAk#Induction diffuser DISA-HDISA-H-D (without grille) Critical throw Length correction factors for air volumes VZU x KF Correction factors for the critical throw Construction subject to change.

 Open the catalog to page 17
DISA-H (2025)-18

Induction diffuser DISA-H Maximum end velocity of jet (isothermal) at floor level Temperature ratio / induction ratio secondary slot - primary air only Length correction factors for air volumes VZU x KF NL 11/15 - 18 Construction subject to change. Version: 14.12.2015 No return possible!

 Open the catalog to page 18
DISA-H (2025)-19

“HAk#Induction diffuser DISA-HDISA-H-E (with grille) Critical throw Maximum end velocity of jet (isotherm) with coanda effect Correction factors for the critical throw Length correction factors for air volumes VZU x KF Critical jet path - Correction factors for PA grille Maximum end velocity of jet - Correction factors for PA grille IB-1 Blade position straight Construction subject to change.

 Open the catalog to page 19
DISA-H (2025)-20

Maximum end velocity of jet (isothermal) at floor level Temperature ratio / induction ratio secondary slot - primary air only Correction factors for temperature ratios TV and Induction ratio Length correction factor for air volumes Maximum end velocity of jet - Correction factors for PA grille Induction ratios and temperature ratios -Correction factors for PA grille PA-1 Blade position straight PA-1 Blade position straight Maximum end velocity of jet - Correction factors for IB grille IB-1 Blade position straight Induction ratios and temperature ratios -Correction factors for IB grille IB-1 Blade...

 Open the catalog to page 20

All SCHAKO KG catalogs and technical brochures

  1. CNVA

    32  Pages

  2. FKW (2025)

    28  Pages

  3. AUDIX

    2  Pages

  4. DISA

    4  Pages

  5. UC-OH²

    2  Pages

  6. IGA

    2  Pages

  7. CDD

    2  Pages

  8. FBS

    18  Pages

  9. PIL

    23  Pages

  10. MWS / MWK

    23  Pages

  11. ERK-SO

    43  Pages

  12. DSCXL

    17  Pages

  13. DSCPL

    16  Pages

  14. BKSYS

    18  Pages

  15. MINODSA

    6  Pages

  16. DKA

    6  Pages

  17. LAQ

    11  Pages

  18. VMPR/VMPQ

    29  Pages

  19. DSCU

    18  Pages

  20. DSCP

    15  Pages

  21. DQJP

    9  Pages

  22. BKA-EN

    79  Pages

  23. CPL

    15  Pages

  24. AUDIX®

    25  Pages

  25. VREX

    26  Pages

  26. VQEX

    17  Pages

  27. VPEX

    18  Pages

  28. SVA-FS

    11  Pages

  29. NRWG

    22  Pages

  30. COMBIDSC

    26  Pages

  31. DSC

    37  Pages

  32. DO

    10  Pages

  33. VRAQ

    46  Pages

  34. UEKU

    6  Pages

  35. UEK

    6  Pages

  36. SS-K

    6  Pages

  37. VOLKOM

    6  Pages

  38. STV

    8  Pages

  39. DQJ

    38  Pages

  40. ALAS-F 125

    6  Pages

  41. ALPETY

    16  Pages

  42. CTT

    23  Pages

  43. KWB

    19  Pages

  44. GREENKIT

    20  Pages

  45. SVA-FF

    15  Pages

  46. FKU

    31  Pages

  47. FKF

    29  Pages

  48. SGA

    5  Pages

  49. DBB

    27  Pages

  50. TVO

    8  Pages

  51. AL

    23  Pages

  52. NBS

    34  Pages

  53. MKAR_MKAQ

    13  Pages

  54. KF

    4  Pages

  55. JK

    16  Pages

  56. HK

    16  Pages

  57. FLAQ

    11  Pages

  58. FG

    14  Pages

  59. ERK-MB

    38  Pages

  60. DISA-360

    32  Pages

  61. DISA-300

    51  Pages

  62. CNV

    29  Pages

  63. BKA-UE

    35  Pages

  64. BAK-240

    16  Pages

  65. Aquaris-Silent

    38  Pages

  66. Aquaris_KWB

    20  Pages

  67. DISA-W

    43  Pages

  68. BDA

    11  Pages

  69. PILB/PILBR

    33  Pages

  70. DAV

    19  Pages

  71. 4DE

    18  Pages

  72. 4DF

    13  Pages

  73. DQC

    16  Pages

  74. DQDL

    16  Pages

  75. IDA

    21  Pages

  76. IKA

    23  Pages

  77. ZMD

    17  Pages

  78. DQF

    15  Pages

  79. DQJF

    12  Pages

  80. DQJA/DQJR

    10  Pages

  81. DQJSL

    17  Pages

  82. DQJSLC

    17  Pages

  83. DHV

    18  Pages

  84. COMBIDQJ

    11  Pages

  85. COMBIPIL

    11  Pages

  86. DSA

    15  Pages

  87. DSARR

    7  Pages

  88. QA

    30  Pages

  89. PUSH

    23  Pages

  90. WQA

    12  Pages

  91. DSX

    25  Pages

  92. DSX-XXL

    23  Pages

  93. AUDIX®-AW

    20  Pages

  94. AUDIX®-ÜSG

    13  Pages

  95. DSX-XXL-W

    25  Pages

  96. SIA

    7  Pages

  97. SAR/SAQ/SARP

    13  Pages

  98. WDA

    32  Pages

  99. BSG

    19  Pages

  100. KG

    19  Pages

  101. IB-Q

    21  Pages

  102. IB-R

    15  Pages

  103. LK

    12  Pages

  104. PA

    32  Pages

  105. DBBR

    6  Pages

  106. KGRR

    17  Pages

  107. DBBRR

    11  Pages

  108. WGARR

    7  Pages

  109. WGA

    29  Pages

  110. ALA

    4  Pages

  111. ALA-R

    4  Pages

  112. ALA-SO

    4  Pages

  113. ALAS

    10  Pages

  114. ALAS-P

    5  Pages

  115. DKAPPs

    6  Pages

  116. EBE/EBP

    52  Pages

  117. DKG

    6  Pages

  118. MBE/MBP

    27  Pages

  119. PIANO

    27  Pages

  120. VAS

    26  Pages

  121. VAQS

    19  Pages

  122. VARS

    26  Pages

  123. VRAPPs

    20  Pages

  124. VRAR

    52  Pages

  125. MAK

    15  Pages

  126. RS-F

    7  Pages

  127. RS

    15  Pages

  128. EasyBus

    24  Pages

  129. DISA-Family

    4  Pages

  130. RMS

    11  Pages

  131. TSR

    5  Pages

  132. VLV

    31  Pages

  133. MBM

    10  Pages

  134. LL

    7  Pages

  135. RR-Complete

    41  Pages

  136. MINODSX

    6  Pages

  137. SPB

    10  Pages

  138. DISA-H

    34  Pages

  139. AQUARIS SILENT

    38  Pages

  140. NBS

    24  Pages

  141. JK-LP/JK-LU

    15  Pages

  142. HKP / HKU

    16  Pages

  143. FKW

    16  Pages

  144. FLARE

    13  Pages

  145. RF

    7  Pages

  146. KGF

    9  Pages

  147. SVA-FF

    8  Pages

  148. BKA-Ü

    35  Pages

  149. BSK-RPR

    60  Pages

  150. BKP-EN

    40  Pages

  151. BAK-240

    6  Pages

  152. BAK-250

    14  Pages

Archived catalogs

  1. DISA-B

    32  Pages

  2. DISA-601

    41  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.