Catalog excerpts

SCHAKOI The DISA family Perfect air-conditioning secured by SCHAKO induction units The best for the planner • A system family for all requirements, not only for new buildings, but also for reconstructions and renovations • Consistently homogeneous and, if required, high performance values for all air-conditioning cases • Extensive system consulting and perfect customer service • Procurement security guaranteed for many years The best for the system builder • Reliable transport all over Europe • Perfect logistics including packaging and delivery • Uniform assembly using uniform tools • Optimised for environmental protection, resulting in less packaging material at the construction site • On-site service possible provided by experienced SCHAKO staff The best for the system operator • Trouble-free operation over many years • Discreet and extremely efficient function • Minimised maintenance costs, often even maintenance-free • Uniformly elegant and markedly function-optimised product design • Harmonic visibility through many design versions SCHAKO | SteigstraRe 25-27 Phone: +49 (0) 7463-980-0 www.schako.com
Open the catalog to page 1
Pure competence in air. • Easy mounting and minimum maintenance costs • Length: 900 to 3000 mm in 300-mm steps, in connection with a standard width of 298 mm; freely suspended: 600 mm • For installation heights from 2.6 to 4 metres • Supply air- Vprim: 12 to 87 m³/h/metre • Cooling - ΔTprim 8K / ΔTWinlet 8K: 270 to 550 W/metre • Heating - ΔTprim iso / ΔTWinlet 20K: up to 770 W/metre (for 4-pipe) • Secondary air grille can be made to rotate without tools for easy cleaning • Secondary air grille in 5 design versions • Easy mounting and minimum maintenance costs • Dimensions: 600 x 600 mm or...
Open the catalog to page 2
Pure competence in air. • Easy mounting and minimum maintenance costs • Length: 900 | 1200 | 1500 mm • For installation heights from 2.6 to 4 metres • Supply air- Vprim: 30 to 300 m³/h • Cooling - ΔTprim 8K / ΔTWinlet 10K: 290 to 2250 W • Heating - ΔTprim iso / ΔTWinlet 20K: for 2-pipe: up to 2682 W for 4-pipe: up to 1380 W • Supply air grille and secondary air grille in 3 design versions each • Easy mounting and minimum maintenance costs • Lengths: 900 to 3000 mm in 300-mm steps, can be combined with extension parts and return air element, Height: 200 mm, optionally with condensate pan:...
Open the catalog to page 3
Pure competence in air. DISA300 • Ceiling induction diffuser • For integrated and positivelocking installation in suspended ceilings or in freely suspended ceiling sails as band or single unit • For offices, meeting rooms, shopping malls, hospital rooms, etc. • Option: with air deflection blades and as supply air/return air combination • Ideal for long air-conditioning distances, can be combined to form several parts DISA360 • Ceiling induction diffuser • For integrated and positive-locking installation in grid ceilings or in freely suspended ceiling sails • For offices, meeting rooms,...
Open the catalog to page 4All SCHAKO KG catalogs and technical brochures
-
CNVA
32 Pages
-
KGF Compact Filter Grille
9 Pages
-
AUDIX
2 Pages
-
DISA
4 Pages
-
UC-OH²
2 Pages
-
IGA
2 Pages
-
CDD
2 Pages
-
FBS
18 Pages
-
MINOPAB
6 Pages
-
PIL
23 Pages
-
MWS / MWK
23 Pages
-
ERK-SO
43 Pages
-
BKSYS
18 Pages
-
MINODSA
6 Pages
-
DKA
6 Pages
-
LAQ
11 Pages
-
VMPR/VMPQ
29 Pages
-
BKA-EN
79 Pages
-
CPL
15 Pages
-
AUDIX®
25 Pages
-
VREX
26 Pages
-
VQEX
17 Pages
-
VPEX
18 Pages
-
SVA-FS
11 Pages
-
NRWG
22 Pages
-
COMBIDSC
26 Pages
-
DSCXL
17 Pages
-
DSCU
18 Pages
-
DSCPL
16 Pages
-
DSCP
15 Pages
-
DSC
37 Pages
-
DO
10 Pages
-
VRAQ
46 Pages
-
UEKU
6 Pages
-
UEK
6 Pages
-
SS-K
6 Pages
-
DQJP
9 Pages
-
VOLKOM
6 Pages
-
DQJ
38 Pages
-
ALPETY
16 Pages
-
CTT
23 Pages
-
STV
8 Pages
-
KWB
19 Pages
-
GREENKIT
20 Pages
-
FKU
31 Pages
-
FKF
29 Pages
-
SGA
5 Pages
-
DBB
27 Pages
-
TVO
8 Pages
-
AL
23 Pages
-
SVA-FF
15 Pages
-
RF Return air filter grille
7 Pages
-
NBS
34 Pages
-
MKAR_MKAQ
13 Pages
-
KF
4 Pages
-
JK
16 Pages
-
HK
16 Pages
-
Lint Separator FLARE
13 Pages
-
FLAQ
11 Pages
-
FKW
28 Pages
-
FG
14 Pages
-
ERK-MB
38 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
CNV
29 Pages
-
BKP-EN Fire damper
40 Pages
-
BKA-UE
35 Pages
-
BAK-250 Fire protection unit
17 Pages
-
BAK-240
16 Pages
-
Aquaris-Silent
38 Pages
-
Aquaris_KWB
20 Pages
-
DISA-W
43 Pages
-
PILB/PILBR
33 Pages
-
DAV
19 Pages
-
4DE
18 Pages
-
4DF
13 Pages
-
DQC
16 Pages
-
DQDL
16 Pages
-
IDA
21 Pages
-
IKA
23 Pages
-
ZMD
17 Pages
-
DQF
15 Pages
-
DQJF
12 Pages
-
DQJA/DQJR
10 Pages
-
DQJSL
17 Pages
-
DQJSLC
17 Pages
-
DHV
18 Pages
-
DSARR
7 Pages
-
QA
30 Pages
-
PUSH
23 Pages
-
WQA
12 Pages
-
DSX-XXL
23 Pages
-
AUDIX®-ÜSG
13 Pages
-
SIA
7 Pages
-
SAR/SAQ/SARP
13 Pages
-
WDA
32 Pages
-
KGRR
17 Pages
-
DBBRR
11 Pages
-
WGARR
7 Pages
-
WGA
29 Pages
-
DKAPPs
6 Pages
-
EBE/EBP
52 Pages
-
VRAPPs
20 Pages
-
VRAR
52 Pages
-
MAK
15 Pages
-
RMS
11 Pages
-
EasyBus
24 Pages
-
TSR
5 Pages
-
RS-F
7 Pages
-
RS
15 Pages
-
VLV
31 Pages
-
VARS
26 Pages
-
VAQS
19 Pages
-
VAS
26 Pages
-
PIANO
27 Pages
-
MBM
10 Pages
-
MBE/MBP
27 Pages
-
DKG
6 Pages
-
ALAS-P
5 Pages
-
ALAS-F 125
6 Pages
-
ALAS
10 Pages
-
ALA-SO
4 Pages
-
ALA-R
4 Pages
-
ALA
4 Pages
-
LL
7 Pages
-
RR-Complete
41 Pages
-
DBBR
6 Pages
-
PA
32 Pages
-
LK
12 Pages
-
IB-R
15 Pages
-
IB-Q
21 Pages
-
KG
19 Pages
-
BSG
19 Pages
-
DSX-XXL-W
25 Pages
-
AUDIX®-AW
20 Pages
-
DSX
25 Pages
-
MINODSX
6 Pages
-
MINODSA
6 Pages
-
DSA
15 Pages
-
COMBIPIL
11 Pages
-
COMBIDQJ
11 Pages
-
MINOPAB
6 Pages
-
BDA
11 Pages
-
SPB
10 Pages
-
CULTRA-Studioline
24 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
AQUARIS SILENT
38 Pages
-
NBS
24 Pages
-
CNV
29 Pages
-
CNVA
32 Pages
-
JK-LP/JK-LU
15 Pages
-
HKP / HKU
16 Pages
-
FKW
16 Pages
-
FLARE
13 Pages
-
RF
7 Pages
-
KGF
9 Pages
-
SVA-FF
8 Pages
-
BKA-Ü
35 Pages
-
BSK-RPR
60 Pages
-
BKP-EN
40 Pages
-
BAK-240
6 Pages
-
BAK-250
14 Pages
-
KF
4 Pages