Catalog excerpts

11/30 - 2 Construction subject to change. Version: 09.05.2014 No return possible!
Open the catalog to page 2
Floor Induction Diffuser DISA-B Description The SCHAKO floor induction diffusers of series DISA-B belong to the group of air/water systems and are suitable, thanks to their induction technology, for discharging high loads using small conditioned external air flows and the energetic benefit of load discharge (heating/cooling) by the medium water. Advantageously, DISA-B are used for room-high glazed buildings without false ceiling and low storey heights. In heating mode, draughts caused by cold air drop and surfaces emitting cold at the façade can be avoided, and in cooling mode the DISA-B...
Open the catalog to page 3
Description of the equipment Construction Housing - Galvanised steel sheet with 1 or 2 primary air connecting pieces 098 and 0123 (standard) - Primary connection pipe position: - Horizontal (-H) - Arrangement of the primary air connecting pieces: - 1 central connecting piece (-AS1, standard) - 2 central connecting pieces and at the same distance (-AS2/ AS3) Louvre grid (-PA-3) - Extruded aluminium profile Roll-down grille (-PA-R) - Extruded aluminium profile Heat exchanger - 4-pipe system (cooling and heating) or optionally 2-pipe system (cooling or heating) - Galvanised sheet steel frame -...
Open the catalog to page 4
Floor Induction Diffuser DISA-B Models and dimensions Dimensions and weights LG NL (mm) = nominal length (1000 / 1150 / 1300 / 1450 / 1600 / 1750 ) LG (mm) = Total length - without valve group integrated on site: (2000 > LG ≥ NL) - with valve group integrated on site: (2000 > LG ≥ NL+150) øD (mm) = diameter of the connection pipe (98 and 123) Arrangement of the connecting pieces (-AS) and water connection (-WS) Connection primary air connecting piece Weights DISA-B Number/position of the connection pipes - with horizontal connection (-H) - with 1 central connecting piece (-AS1) - with 2...
Open the catalog to page 5
with 1 horizontal connecting piece (-AS1) 012 mm outside Position of primary air plenum box (-L) Prepunched passages for water connections -262,5 212,5 Construction subject to change. Variable dimension, depending on the configuration of the unit
Open the catalog to page 6
Floor Induction Diffuser DISA-B Flexible armoured hose with stainless steel braid, oxygen diffusion layer to DIN 4726, one-sided by means of plug-in fitting 90° with stainless steel claw, support ring, 2 sealing rings (operating pressure 20 bar, test pressure 60 bar, temperature -40° to +80°) and lock washer, other side 1/2" spigot nut with flat seal. L= 500, 800 and 1200 mm. Other lengths on request. Adjusting legs For adjusting the device height (up to 50 mm) External thread flat-sealing Water connections 1/2" external thread flat-sealing Ball valve to shut off the register to a hydraulic...
Open the catalog to page 7
Floor Induction Diffuser DISA-B Technical data Performance data DISA-B-H -...-B -Cooling-
Open the catalog to page 8
11/30 - 24Construction subject to change. Version: 09.05.2014
Open the catalog to page 24
Floor Induction Diffuser DISA-BControl units Valves 2-way valves (series VD115CLC) Nominal diameter 15 mm Connections inner and outer thread 1/2 inch thick Manual setting button/protective cap included in delivery Valve with adjustable kv by means of a ring 0.25-1.9 m3/h Drives SSA (100 N) and STA (100 N) Straight lockshields (ADN series) - Nominal diameters 10,15 and 20 mm - Connections inner and outer thread 1/2 inch - Manual setting button/protective cap included in delivery - Valve with adjustable kv by means of a ring 0.15-3 m3/h Compatible drives: (1) in connection with room...
Open the catalog to page 25
Floor Induction Diffuser DISA-B Actuators Model SSA Model STA - Actuating power 100 N - Automatic detection of the valve stroke - Simple installation - Standard version including 1, 2 or 5 m connecting cables - Direct mounting - Manual adjustment and position indicator - Motion and position indicator - Connecting cable lengths 1.5, 2.5 and 4.5 m - Pulse duration modulation (PDM) (room temperature controls RDG and RCU) - Two-wire connection SSA31: actuator 230 V AC, 3-point activation SSA61: actuator 24 V AC/DC, activation 0...10 V DC SSA81: actuator 24 V AC, 3-point activation STA23:...
Open the catalog to page 26
ICHAK#Floor Induction Diffuser DISA-B Model RCU 15 Control unitsModel RCU 10 2-point or steady control with PI behaviour, as desired, combined with model STA On/Off or PWM signal Operating mode switchover contact input for remote circuit Operating voltage AC 230 V Optional 2-point or steady control with PI behaviour, as desired ON/OFF or PWM actuator signal outputs Standard, Economy and Stand-by operating modes Operating mode switchover contact input for remote circuit Operating voltage AC 24 V L, N Operating voltage AC 230 V D1, GND Signal input for potential-free operating mode switch Y1,...
Open the catalog to page 27
- Room thermostat with manual switch for heating or cooling - Two-point control behaviour - Switching voltage AC 24...250 V Connection diagram: D1 Zone valves or thermal valves L Switching voltage AC 24...250 V S Selector switch Heating / OFF / Cooling Y Control output "Heating" or "Cooling", AC 24...250 V N Operating voltage zero - Display with backlight - Automatic switchover between heating and cooling mode via sensor QAH11.1 (optional) - Operating modes: Comfort, Economy and Protective modes - PWM regulation, optional - Automatic mode with timer program - Optional RDG KNX communication...
Open the catalog to page 28
QXA2602 QXA2604 - Operating voltage AC/DC 24 V or AC 230 V - Potential-free changeover contact AC/DC 1...30V or AC 230V - Quick and simple installation - Flat or pre-assembly - Integrated and remote sensor available - Status display via two-colour LED Mode of action: The condensation monitor detects the relative humidity near the dew point (= 100% of r. h.) via its moisture-sensitive element. During this detection, the resistance value of the element increases considerably between 90 ... 100% of r. h. Before reaching the dew point, the electronics of the relay switches. A changeover of the...
Open the catalog to page 29
Floor Induction Diffuser DISA-B Assembly The DISA-B series is suitable for horizontal assembly in false floors. Thanks to the adjustable legs and the mounting plates, the DISA-B can also be levelled from the room side, after completed assembly. The floor induction diffuser DISA-Bis particulary maintenance-friendly. Grille, register and plenum box are cleaned with an industrial vacuum cleaner or steam cleaner or by spraying it with Apmax (kPa) a non-aggressive cleaner. Nominal length Total length Primary air flow Standard amount of water flow Static pressure Water-side pressure loss Primary...
Open the catalog to page 30All SCHAKO KG catalogs and technical brochures
-
CNVA
32 Pages
-
KGF Compact Filter Grille
9 Pages
-
AUDIX
2 Pages
-
DISA
4 Pages
-
UC-OH²
2 Pages
-
IGA
2 Pages
-
CDD
2 Pages
-
FBS
18 Pages
-
MINOPAB
6 Pages
-
PIL
23 Pages
-
MWS / MWK
23 Pages
-
ERK-SO
43 Pages
-
BKSYS
18 Pages
-
MINODSA
6 Pages
-
DKA
6 Pages
-
LAQ
11 Pages
-
VMPR/VMPQ
29 Pages
-
BKA-EN
79 Pages
-
CPL
15 Pages
-
AUDIX®
25 Pages
-
VREX
26 Pages
-
VQEX
17 Pages
-
VPEX
18 Pages
-
SVA-FS
11 Pages
-
NRWG
22 Pages
-
COMBIDSC
26 Pages
-
DSCXL
17 Pages
-
DSCU
18 Pages
-
DSCPL
16 Pages
-
DSCP
15 Pages
-
DSC
37 Pages
-
DO
10 Pages
-
VRAQ
46 Pages
-
UEKU
6 Pages
-
UEK
6 Pages
-
SS-K
6 Pages
-
DQJP
9 Pages
-
VOLKOM
6 Pages
-
DQJ
38 Pages
-
ALPETY
16 Pages
-
CTT
23 Pages
-
STV
8 Pages
-
KWB
19 Pages
-
GREENKIT
20 Pages
-
FKU
31 Pages
-
FKF
29 Pages
-
SGA
5 Pages
-
DBB
27 Pages
-
TVO
8 Pages
-
AL
23 Pages
-
SVA-FF
15 Pages
-
RF Return air filter grille
7 Pages
-
NBS
34 Pages
-
MKAR_MKAQ
13 Pages
-
KF
4 Pages
-
JK
16 Pages
-
HK
16 Pages
-
Lint Separator FLARE
13 Pages
-
FLAQ
11 Pages
-
FKW
28 Pages
-
FG
14 Pages
-
ERK-MB
38 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
CNV
29 Pages
-
BKP-EN Fire damper
40 Pages
-
BKA-UE
35 Pages
-
BAK-250 Fire protection unit
17 Pages
-
BAK-240
16 Pages
-
Aquaris-Silent
38 Pages
-
Aquaris_KWB
20 Pages
-
DISA-W
43 Pages
-
PILB/PILBR
33 Pages
-
DAV
19 Pages
-
4DE
18 Pages
-
4DF
13 Pages
-
DQC
16 Pages
-
DQDL
16 Pages
-
IDA
21 Pages
-
IKA
23 Pages
-
ZMD
17 Pages
-
DQF
15 Pages
-
DQJF
12 Pages
-
DQJA/DQJR
10 Pages
-
DQJSL
17 Pages
-
DQJSLC
17 Pages
-
DHV
18 Pages
-
DSARR
7 Pages
-
QA
30 Pages
-
PUSH
23 Pages
-
WQA
12 Pages
-
DSX-XXL
23 Pages
-
AUDIX®-ÜSG
13 Pages
-
SIA
7 Pages
-
SAR/SAQ/SARP
13 Pages
-
WDA
32 Pages
-
KGRR
17 Pages
-
DBBRR
11 Pages
-
WGARR
7 Pages
-
WGA
29 Pages
-
DKAPPs
6 Pages
-
EBE/EBP
52 Pages
-
VRAPPs
20 Pages
-
VRAR
52 Pages
-
MAK
15 Pages
-
DISA-Family
4 Pages
-
RMS
11 Pages
-
EasyBus
24 Pages
-
TSR
5 Pages
-
RS-F
7 Pages
-
RS
15 Pages
-
VLV
31 Pages
-
VARS
26 Pages
-
VAQS
19 Pages
-
VAS
26 Pages
-
PIANO
27 Pages
-
MBM
10 Pages
-
MBE/MBP
27 Pages
-
DKG
6 Pages
-
ALAS-P
5 Pages
-
ALAS-F 125
6 Pages
-
ALAS
10 Pages
-
ALA-SO
4 Pages
-
ALA-R
4 Pages
-
ALA
4 Pages
-
LL
7 Pages
-
RR-Complete
41 Pages
-
DBBR
6 Pages
-
PA
32 Pages
-
LK
12 Pages
-
IB-R
15 Pages
-
IB-Q
21 Pages
-
KG
19 Pages
-
BSG
19 Pages
-
DSX-XXL-W
25 Pages
-
AUDIX®-AW
20 Pages
-
DSX
25 Pages
-
MINODSX
6 Pages
-
MINODSA
6 Pages
-
DSA
15 Pages
-
COMBIPIL
11 Pages
-
COMBIDQJ
11 Pages
-
MINOPAB
6 Pages
-
BDA
11 Pages
-
SPB
10 Pages
-
CULTRA-Studioline
24 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
AQUARIS SILENT
38 Pages
-
NBS
24 Pages
-
CNV
29 Pages
-
CNVA
32 Pages
-
JK-LP/JK-LU
15 Pages
-
HKP / HKU
16 Pages
-
FKW
16 Pages
-
FLARE
13 Pages
-
RF
7 Pages
-
KGF
9 Pages
-
SVA-FF
8 Pages
-
BKA-Ü
35 Pages
-
BSK-RPR
60 Pages
-
BKP-EN
40 Pages
-
BAK-240
6 Pages
-
BAK-250
14 Pages
-
KF
4 Pages
Archived catalogs
-
DISA-601
41 Pages