11/05 - 2 Construction subject to change. Version: 20.10.2015 No return possible!
Open the catalog to page 2Ceiling induction diffuser DISA-300 Description Ceiling induction diffusers combine the flow characteristics of air diffusers with the energetic advantages of load discharge via water-based heat exchangers, allowing them to remove high thermal loads from the room while keeping the hygienically required air exchange low. The construction of the ceiling induction diffuser DISA-300 is very maintenance- and mounting-friendly and is also suitable for low false ceiling heights, due to its small height. Its 4 different nozzle configurations A, B, C, D and lengths of up to 3.0 metres allow the ceiling...
Open the catalog to page 3Ceiling induction diffuser DISA-300 Model DISA-300-1-... DISA-300-2-... DISA-300-H DISA-300-HT DISA-300-BO DISA-...-LE DISA-...-LB DISA-...-SR DISA-...-SQ DISA-...-RE DISA-...-OB DISA-...-PA DISA-...-A DISA-...-B DISA-...-C DISA-...-D Description of the equipment Construction Housing - Galvanised steel sheet with 1 or 2 primary air connecting pieces 098, 0123 (standard) and 0148 mm. Return air connecting piece as an option. - Connecting piece position for primary and return air: - Horizontal (-H) - Vertical (-V) - Arrangement of the primary air connecting pieces: - 1 horizontal connecting piece...
Open the catalog to page 4Ceiling induction diffuser DISA-300 Models and dimensions Dimensions and weights DISA-300-1 LG* (mm) = total length of the device with and without end pieces wc,h p5rforated sheet grille (-SR/-SQ/- 0D (mm) = diameter of the connection pipes (98, 123 and 148) LG* (mm) = total length of the device with and without end pieces B (mm) = 298 / 600 (-FM) 0D (mm) = diameter of the connection pipes (98, 123 and 148) with perforated sheet grille (-SR/-SQ/-RE/-OB) with louvre grid (-PA) Weights DISA-300 NL (1) Standard unit: housing + slot + grille and heat exchanger (empty) Construction subject to change....
Open the catalog to page 5Ceiling induction diffuser DISA-300 Arrangement of the connecting pieces (-AS) and water connection (-WS) Number/position of the connecting pieces - with horizontal connection (-H) - with 1 central connecting piece (-AS1) or (-AS4) - with 2 connecting pieces (-AS2/AS3) or (-AS5/AS6) - with vertical connection (-V) - with 1 central connecting piece (-AS7) - with 2 connecting pieces (-AS8/AS9) Number/position of the water connections - with 2 water connections (2-pipe system, standard) - with 4 water connections (4-pipe system) - sideways top left (-WS1) - sideways top right (-WS2) Vertical connection...
Open the catalog to page 6Ceiling induction diffuser DISA-300 Return air connecting piece arrangement(-A) Number/position of the return air connecting pieces - with horizontal connection (-H) - Right front (R1) or right back (R2) - Left front (L1) or left back (L2) - with vertical connection (-V) - Right (R) - Left (L) Heating Cooling Housing position Heating Cooling DISA-300-2-...- Perforated sheet grille- Design DISA-...-SR DISA-...-SQ DISA-...-RE 11/05 - 7 Construction subject to change. Version: 20.10.2015 No return possible!
Open the catalog to page 7Ceiling induction diffuser DISA-300 Fixing lugs - Individually adjustable air deflection blades (-LE) - Blockwise adjustable air deflection blades (-LB) With blockwise adjustable blades, 5 blades can be adjusted simultaneously. A The adjusting angle of the air deflection blades /' \ must not be more than ± 45°, in order to guarantee its function. A At an adjusting angle of the air deflection blades outside the straight air throw of up to 45°, the cooling capacity of the heat exchanger is reduced by up to 5%, and the horizontal throw is reduced. Construction subject to change.
Open the catalog to page 8Ceiling induction diffuser DISA-300 Accessories Flexible connection hoses (-FA) Flexible armoured hose with stainless steel braid, oxygen diffusion layer to DIN 4726, one-sided by means of plug-in fitting 90° with stainless steel claw, support ring, 2 sealing rings (operating pressure 20 bar, test pressure 60 bar, temperature -40° to +80°) and lock washer, other side 1/2" spigot nut with flat seal. L= 500, 800 and 1200 mm. Other lengths on request. External thread flat-sealing Water connections 1/2" external thread flat-sealing Rubber lip seal (-GD) at the connection pipe for better tightness....
Open the catalog to page 9Ceiling induction diffuser DISA-300 Figures DISA-300 with end piece (-2E, standard) DISA-300-1-H DISA-300 band design without end pieces mounted in-between System solution SCHAKO offers system solutions that can be integrated perfectly into the room architecture. Example of a system solution with lighting and sprinkler DISA-300 with foldable grille DISA-300-1-H 11/05 - 10 Construction subject to change. Version: 20.10.2015 No return possible!
Open the catalog to page 10Ceiling induction diffuser DISA-300Technical data Performance data DISA-300-1-H-...-A Cooling NL (mm)
Open the catalog to page 11Ceiling induction diffuser DISA-300DISA-300-1-HT-...-A Cooling NL (mm)
Open the catalog to page 12Ceiling induction diffuser DISA-300DISA-300-2-H-...-A Cooling NL (mm)
Open the catalog to page 13Ceiling induction diffuser DISA-300DISA300-2-HT-...-A Cooling NL (mm)
Open the catalog to page 14Ceiling induction diffuser DISA-300DISA-300-1-H-...-B Cooling NL (mm)
Open the catalog to page 15Ceiling induction diffuser DISA-300DISA-300-1-HT-...-B Cooling NL (mm)
Open the catalog to page 16Ceiling induction diffuser DISA-300DISA-300-2-H-...-B Cooling NL (mm)
Open the catalog to page 17Ceiling induction diffuser DISA-300DISA-300-2-HT-...-B Cooling NL (mm)
Open the catalog to page 18Ceiling induction diffuser DISA-300DISA-300-1-H-...-C Cooling NL (mm)
Open the catalog to page 19Ceiling induction diffuser DISA-300DISA-300-1-HT-...-C Cooling NL (mm)
Open the catalog to page 20Ceiling induction diffuser DISA-300DISA-300-2-H-...-C Cooling NL (mm)
Open the catalog to page 21Ceiling induction diffuser DISA-300DISA-300-2-HT-...-C Cooling NL (mm)
Open the catalog to page 22Ceiling induction diffuser DISA-300DISA-300-1-H-...-D Cooling NL (mm)
Open the catalog to page 23Ceiling induction diffuser DISA-300DISA-300-1-HT-...-D Cooling NL (mm)
Open the catalog to page 24Ceiling induction diffuser DISA-300DISA-300-2-H-...-D Cooling NL (mm)
Open the catalog to page 25Ceiling induction diffuser DISA-300DISA-300-2-HT-...-D Cooling NL (mm)
Open the catalog to page 26Ceiling induction diffuser DISA-300DISA-300-1-H-...-A Heating NL (mm) Construction subject to change.
Open the catalog to page 27Ceiling induction diffuser DISA-300DISA-300-1-HT-...-A Heating NL (mm) Construction subject to change.
Open the catalog to page 2832 Pages
28 Pages
9 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
18 Pages
6 Pages
23 Pages
23 Pages
43 Pages
17 Pages
16 Pages
18 Pages
6 Pages
6 Pages
11 Pages
29 Pages
18 Pages
15 Pages
9 Pages
79 Pages
15 Pages
25 Pages
26 Pages
17 Pages
18 Pages
11 Pages
22 Pages
26 Pages
37 Pages
10 Pages
46 Pages
6 Pages
6 Pages
6 Pages
6 Pages
8 Pages
38 Pages
6 Pages
16 Pages
23 Pages
19 Pages
20 Pages
15 Pages
31 Pages
29 Pages
5 Pages
27 Pages
8 Pages
23 Pages
7 Pages
34 Pages
13 Pages
4 Pages
16 Pages
16 Pages
13 Pages
11 Pages
14 Pages
38 Pages
34 Pages
32 Pages
29 Pages
40 Pages
35 Pages
17 Pages
16 Pages
38 Pages
20 Pages
43 Pages
24 Pages
11 Pages
33 Pages
19 Pages
18 Pages
13 Pages
16 Pages
16 Pages
21 Pages
23 Pages
17 Pages
15 Pages
12 Pages
10 Pages
17 Pages
17 Pages
18 Pages
11 Pages
11 Pages
15 Pages
7 Pages
30 Pages
23 Pages
12 Pages
25 Pages
23 Pages
20 Pages
13 Pages
25 Pages
7 Pages
13 Pages
32 Pages
19 Pages
19 Pages
21 Pages
15 Pages
12 Pages
32 Pages
6 Pages
17 Pages
11 Pages
7 Pages
29 Pages
4 Pages
4 Pages
4 Pages
10 Pages
5 Pages
6 Pages
52 Pages
6 Pages
27 Pages
27 Pages
26 Pages
19 Pages
26 Pages
20 Pages
52 Pages
15 Pages
7 Pages
15 Pages
24 Pages
4 Pages
11 Pages
5 Pages
31 Pages
10 Pages
7 Pages
41 Pages
6 Pages
10 Pages
34 Pages
38 Pages
24 Pages
15 Pages
16 Pages
16 Pages
13 Pages
7 Pages
9 Pages
8 Pages
35 Pages
60 Pages
40 Pages
6 Pages
14 Pages