CPL
1 /15Pages

CPL

CPL
1 /15Pages

Catalog excerpts

CPL-1

Technical documentation SCHAKO | Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen

 Open the catalog to page 1
CPL-2

Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Function and use I Processing FUNCTION AND USE CPL-E-... CPL-...-Z-... CPL-...-A-... CPL-...-3-... CPL-...-5-... CPL-...-300-... CPL-...-312-... CPL-...-600-... CPL-...-625-... The ceiling air diffuser type CPL for supply and return air is suitable for use in rooms from 2.6 to 4 m high. With the supply air model, a special intake funnel behind an existing on-site perforated ceiling panel creates a horizontal air jet below the ceiling for cooling mode and isothermal ventilation mode. A high induction is achieved while the velocity and temperature...

 Open the catalog to page 2
CPL-3

Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Dimensions I CPL-E-... (ceiling air diffuser mounted to the ceiling panel) FQ = 16.2 % (RG-L15; 02.5 mm) FQ = 25.0 % (RV-L6; 02.1 mm) DPB = ceiling panel width DPL = ceiling panel length - = not possible Construction subject to change No return possible Version: 2020-03-24 | Page 3

 Open the catalog to page 3
CPL-4

TECHNICAL DOCUMENTATION Dimensions of accessories I DIMENSIONS OF ACCESSORIES Plenum box (-SK) SK-...-S1 (standard), lateral spigot external Rubber seal (made of EPDM) CPL CPL and SK are not permanently connected to one another. SK-...-S0, spigot from above external Air diffuser plate (for supply air model only) With the VME1 model, the projection dimension is approx. 102 mm. KHS= standard height of plenum box Special height of plenum box øD + 137 mm, but at least 235 mm. Spigot position - 1 spigot from above (-S0) 1 lateral spigot (-S1) (standard) 2 lateral spigots, offset by 90° (-S2) 2 lateral...

 Open the catalog to page 4
CPL-5

Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Dimensions of accessories I Connection to flexible duct Lateral spigot spigot from above Connection elbow (-K030/-K045/-K090) according to DIN EN 1506, consisting of a BGE bend made of galvanised sheet steel. Only possible without plenum box! Bend model: - as a pressed BGE bend with an angle degree: a = 30° (-K030) a = 45° (-K045) a = 90° (-K090) Volumetric flow meter (-VME1), for SK Bend supplied lose, inserted and screwed on site, screws provided on site Internal or external insulation (-Ii / -Ia), for SK Construction subject to change No return...

 Open the catalog to page 5
CPL-6

TECHNICAL DOCUMENTATION Technical data I TECHNICAL DATA Pressure loss and noise level for supply air / with plenum box and damper Damper position (DS): 0% = CLOSED 100% = OPEN Z = supply air with on-site ceiling panel FQ 16.2% (RG-L15; ø2.5) CPL-E-Z-3-…-SK-...-DK1 with on-site ceiling panel FQ 25% (RV-L6; ø2.1) CPL-E-Z-3-…-SK-...-DK1 Construction subject to change No return possible

 Open the catalog to page 6
CPL-7

TECHNICAL DOCUMENTATION Technical data I for return air / with plenum box and damper Damper position (DS): 0% = CLOSED 100% = OPEN A = return air with on-site ceiling panel FQ 16.2% (RG-L15; ø2.5) CPL-E-A-3-…-SK-...-DK1 with on-site ceiling panel FQ 25% (RV-L6; ø2.1) CPL-E-A-3-…-SK-...-DK1 Construction subject to change No return possible

 Open the catalog to page 7
CPL-8

TECHNICAL DOCUMENTATION Technical data I for return air / with connection elbow with on-site ceiling panel for supply air / with connection elbow with on-site ceiling panel on-site ceiling panel: FQ 25% = RV-L6; ø2.1 FQ 16.2% = RG-L15; ø2.5 Construction subject to change No return possible

 Open the catalog to page 8
CPL-9

TECHNICAL DOCUMENTATION Technical data I with on-site ceiling panel FQ 16.2% (RG-L15; ø2.5) with on-site ceiling panel FQ 25% (RV-L6; ø2.1) Construction subject to change No return possible

 Open the catalog to page 9
CPL-10

TECHNICAL DOCUMENTATION Technical data I Critical throw with on-site ceiling panel FQ 16.2% (RG-L15; ø2.5) with on-site ceiling panel FQ 25% (RV-L6; ø2.1) Construction subject to change No return possible

 Open the catalog to page 10
CPL-11

TECHNICAL DOCUMENTATION Technical data I Temperature and induction ratios with on-site ceiling panel FQ 16.2% (RG-L15; ø2.5) with on-site ceiling panel FQ 25% (RV-L6; ø2.1) Construction subject to change No return possible

 Open the catalog to page 11
CPL-12

Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Minimum air volumes I Legend Vzu (m3/h) [l/s] Vab (m3/h) [l/s] Vmin (m3/h) [l/s] Lwa [dB(A)] Apt (Pa) P (kg/m3) DS (%) FQ (%) Vmax (m/s) x (m) y (m) x+y (m) Vmittel (m/s) Xkr (m) ATo (K) Ceiling air diffuser type CPL-Z (supply air) with on-site perforated ceiling panel - FQ = 16.2% (RG-L15; 02.5) Supply air volume Return air volume Minimum volume A-weighted sound power level Total pressure loss Density Damper position Free cross-section Maximum end velocity of jet horizontal throw vertical throw horizontal + vertical throw Average end velocity...

 Open the catalog to page 12
CPL-13

Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Order code CPL I Sample CPL-E-Z-5-600-AL-K000 Ceiling air diffuser type CPL | only ceiling air diffuser | supply air | NW 500| ceiling panel width 600 mm | aluminium painted to the RAL colour 9005 (black) | without connection elbow ORDER DETAILS 01 - Type CPL = ceiling air diffuser CPL 02 - Model E = only ceiling air diffuser 03 - Air throw Z = supply air (standard), with central disc 04 - Nominal size of intake funnel 3 = NW 300 05 - Ceiling panel width 300 = Ceiling panel width 300 mm (not possible for NW 500) 312 = Ceiling panel width 312 mm...

 Open the catalog to page 13
CPL-14

Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Order code SK I Sample SK-R-71-Z-500-OM-SV-DK1-GD1-VME0-ROB0-I0-KHS-SDS-S1 Plenum box, square design | for round air diffusers with round diffuser support | air diffuser CPL | supply air | NW 500 | without mounting | galvanised sheet steel | with damper | with rubber lip seal | without volumetric flow meter | without ROB version | without box insulation | standard height of plenum box | standard spigot diameter | 1 lateral spigot ORDER DETAILS 01 - Type SK = plenum box, square design 02 - Model R = for round air diffusers with round diffuser support...

 Open the catalog to page 14
CPL-15

Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Specification text I Ceiling air diffuser type CPL for supply and return air for use in rooms from 2.6 to 4 m high. Highly inductive air diffuser, air velocity and temperature difference of the supply air jet are effectively reduced. The stable air jet and high induction mean that the CPL ceiling air diffuser can be used in cooling mode up to ATO < -10 K. Consists of an adaptor plate and intake funnel made of aluminium painted to the RAL colour RAL 9005 (black). With supply air model additionally with central disc made of galvanised sheet steel....

 Open the catalog to page 15

All SCHAKO KG catalogs and technical brochures

  1. CNVA

    32  Pages

  2. FKW (2025)

    28  Pages

  3. AUDIX

    2  Pages

  4. DISA

    4  Pages

  5. UC-OH²

    2  Pages

  6. IGA

    2  Pages

  7. CDD

    2  Pages

  8. FBS

    18  Pages

  9. PIL

    23  Pages

  10. MWS / MWK

    23  Pages

  11. ERK-SO

    43  Pages

  12. DSCXL

    17  Pages

  13. DSCPL

    16  Pages

  14. BKSYS

    18  Pages

  15. MINODSA

    6  Pages

  16. DKA

    6  Pages

  17. LAQ

    11  Pages

  18. VMPR/VMPQ

    29  Pages

  19. DSCU

    18  Pages

  20. DSCP

    15  Pages

  21. DQJP

    9  Pages

  22. BKA-EN

    79  Pages

  23. AUDIX®

    25  Pages

  24. VREX

    26  Pages

  25. VQEX

    17  Pages

  26. VPEX

    18  Pages

  27. SVA-FS

    11  Pages

  28. NRWG

    22  Pages

  29. COMBIDSC

    26  Pages

  30. DSC

    37  Pages

  31. DO

    10  Pages

  32. VRAQ

    46  Pages

  33. UEKU

    6  Pages

  34. UEK

    6  Pages

  35. SS-K

    6  Pages

  36. VOLKOM

    6  Pages

  37. STV

    8  Pages

  38. DQJ

    38  Pages

  39. ALAS-F 125

    6  Pages

  40. ALPETY

    16  Pages

  41. CTT

    23  Pages

  42. KWB

    19  Pages

  43. GREENKIT

    20  Pages

  44. SVA-FF

    15  Pages

  45. FKU

    31  Pages

  46. FKF

    29  Pages

  47. SGA

    5  Pages

  48. DBB

    27  Pages

  49. TVO

    8  Pages

  50. AL

    23  Pages

  51. NBS

    34  Pages

  52. MKAR_MKAQ

    13  Pages

  53. KF

    4  Pages

  54. JK

    16  Pages

  55. HK

    16  Pages

  56. FLAQ

    11  Pages

  57. FG

    14  Pages

  58. ERK-MB

    38  Pages

  59. DISA-H (2025)

    34  Pages

  60. DISA-360

    32  Pages

  61. DISA-300

    51  Pages

  62. CNV

    29  Pages

  63. BKA-UE

    35  Pages

  64. BAK-240

    16  Pages

  65. Aquaris-Silent

    38  Pages

  66. Aquaris_KWB

    20  Pages

  67. DISA-W

    43  Pages

  68. BDA

    11  Pages

  69. PILB/PILBR

    33  Pages

  70. DAV

    19  Pages

  71. 4DE

    18  Pages

  72. 4DF

    13  Pages

  73. DQC

    16  Pages

  74. DQDL

    16  Pages

  75. IDA

    21  Pages

  76. IKA

    23  Pages

  77. ZMD

    17  Pages

  78. DQF

    15  Pages

  79. DQJF

    12  Pages

  80. DQJA/DQJR

    10  Pages

  81. DQJSL

    17  Pages

  82. DQJSLC

    17  Pages

  83. DHV

    18  Pages

  84. COMBIDQJ

    11  Pages

  85. COMBIPIL

    11  Pages

  86. DSA

    15  Pages

  87. DSARR

    7  Pages

  88. QA

    30  Pages

  89. PUSH

    23  Pages

  90. WQA

    12  Pages

  91. DSX

    25  Pages

  92. DSX-XXL

    23  Pages

  93. AUDIX®-AW

    20  Pages

  94. AUDIX®-ÜSG

    13  Pages

  95. DSX-XXL-W

    25  Pages

  96. SIA

    7  Pages

  97. SAR/SAQ/SARP

    13  Pages

  98. WDA

    32  Pages

  99. BSG

    19  Pages

  100. KG

    19  Pages

  101. IB-Q

    21  Pages

  102. IB-R

    15  Pages

  103. LK

    12  Pages

  104. PA

    32  Pages

  105. DBBR

    6  Pages

  106. KGRR

    17  Pages

  107. DBBRR

    11  Pages

  108. WGARR

    7  Pages

  109. WGA

    29  Pages

  110. ALA

    4  Pages

  111. ALA-R

    4  Pages

  112. ALA-SO

    4  Pages

  113. ALAS

    10  Pages

  114. ALAS-P

    5  Pages

  115. DKAPPs

    6  Pages

  116. EBE/EBP

    52  Pages

  117. DKG

    6  Pages

  118. MBE/MBP

    27  Pages

  119. PIANO

    27  Pages

  120. VAS

    26  Pages

  121. VAQS

    19  Pages

  122. VARS

    26  Pages

  123. VRAPPs

    20  Pages

  124. VRAR

    52  Pages

  125. MAK

    15  Pages

  126. RS-F

    7  Pages

  127. RS

    15  Pages

  128. EasyBus

    24  Pages

  129. DISA-Family

    4  Pages

  130. RMS

    11  Pages

  131. TSR

    5  Pages

  132. VLV

    31  Pages

  133. MBM

    10  Pages

  134. LL

    7  Pages

  135. RR-Complete

    41  Pages

  136. MINODSX

    6  Pages

  137. SPB

    10  Pages

  138. DISA-H

    34  Pages

  139. AQUARIS SILENT

    38  Pages

  140. NBS

    24  Pages

  141. JK-LP/JK-LU

    15  Pages

  142. HKP / HKU

    16  Pages

  143. FKW

    16  Pages

  144. FLARE

    13  Pages

  145. RF

    7  Pages

  146. KGF

    9  Pages

  147. SVA-FF

    8  Pages

  148. BKA-Ü

    35  Pages

  149. BSK-RPR

    60  Pages

  150. BKP-EN

    40  Pages

  151. BAK-240

    6  Pages

  152. BAK-250

    14  Pages

Archived catalogs

  1. DISA-B

    32  Pages

  2. DISA-601