Catalog excerpts

Technical documentation SCHAKO | Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen
Open the catalog to page 1
Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Function and use I Processing FUNCTION AND USE CPL-E-... CPL-...-Z-... CPL-...-A-... CPL-...-3-... CPL-...-5-... CPL-...-300-... CPL-...-312-... CPL-...-600-... CPL-...-625-... The ceiling air diffuser type CPL for supply and return air is suitable for use in rooms from 2.6 to 4 m high. With the supply air model, a special intake funnel behind an existing on-site perforated ceiling panel creates a horizontal air jet below the ceiling for cooling mode and isothermal ventilation mode. A high induction is achieved while the velocity and...
Open the catalog to page 2
Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Dimensions I CPL-E-... (ceiling air diffuser mounted to the ceiling panel) FQ = 16.2 % (RG-L15; 02.5 mm) FQ = 25.0 % (RV-L6; 02.1 mm) DPB = ceiling panel width DPL = ceiling panel length - = not possible Construction subject to change No return possible Version: 2020-03-24 | Page 3
Open the catalog to page 3
TECHNICAL DOCUMENTATION Dimensions of accessories I DIMENSIONS OF ACCESSORIES Plenum box (-SK) SK-...-S1 (standard), lateral spigot external Rubber seal (made of EPDM) CPL CPL and SK are not permanently connected to one another. SK-...-S0, spigot from above external Air diffuser plate (for supply air model only) With the VME1 model, the projection dimension is approx. 102 mm. KHS= standard height of plenum box Special height of plenum box øD + 137 mm, but at least 235 mm. Spigot position - 1 spigot from above (-S0) 1 lateral spigot (-S1) (standard) 2 lateral spigots, offset by 90° (-S2) 2...
Open the catalog to page 4
Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Dimensions of accessories I Connection to flexible duct Lateral spigot spigot from above Connection elbow (-K030/-K045/-K090) according to DIN EN 1506, consisting of a BGE bend made of galvanised sheet steel. Only possible without plenum box! Bend model: - as a pressed BGE bend with an angle degree: a = 30° (-K030) a = 45° (-K045) a = 90° (-K090) Volumetric flow meter (-VME1), for SK Bend supplied lose, inserted and screwed on site, screws provided on site Internal or external insulation (-Ii / -Ia), for SK Construction subject to change No...
Open the catalog to page 5
TECHNICAL DOCUMENTATION Technical data I TECHNICAL DATA Pressure loss and noise level for supply air / with plenum box and damper Damper position (DS): 0% = CLOSED 100% = OPEN Z = supply air with on-site ceiling panel FQ 16.2% (RG-L15; ø2.5) CPL-E-Z-3-…-SK-...-DK1 with on-site ceiling panel FQ 25% (RV-L6; ø2.1) CPL-E-Z-3-…-SK-...-DK1 Construction subject to change No return possible
Open the catalog to page 6
TECHNICAL DOCUMENTATION Technical data I for return air / with plenum box and damper Damper position (DS): 0% = CLOSED 100% = OPEN A = return air with on-site ceiling panel FQ 16.2% (RG-L15; ø2.5) CPL-E-A-3-…-SK-...-DK1 with on-site ceiling panel FQ 25% (RV-L6; ø2.1) CPL-E-A-3-…-SK-...-DK1 Construction subject to change No return possible
Open the catalog to page 7
TECHNICAL DOCUMENTATION Technical data I for return air / with connection elbow with on-site ceiling panel for supply air / with connection elbow with on-site ceiling panel on-site ceiling panel: FQ 25% = RV-L6; ø2.1 FQ 16.2% = RG-L15; ø2.5 Construction subject to change No return possible
Open the catalog to page 8
TECHNICAL DOCUMENTATION Technical data I with on-site ceiling panel FQ 16.2% (RG-L15; ø2.5) with on-site ceiling panel FQ 25% (RV-L6; ø2.1) Construction subject to change No return possible
Open the catalog to page 9
TECHNICAL DOCUMENTATION Technical data I Critical throw with on-site ceiling panel FQ 16.2% (RG-L15; ø2.5) with on-site ceiling panel FQ 25% (RV-L6; ø2.1) Construction subject to change No return possible
Open the catalog to page 10
TECHNICAL DOCUMENTATION Technical data I Temperature and induction ratios with on-site ceiling panel FQ 16.2% (RG-L15; ø2.5) with on-site ceiling panel FQ 25% (RV-L6; ø2.1) Construction subject to change No return possible
Open the catalog to page 11
Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Minimum air volumes I Legend Vzu (m3/h) [l/s] Vab (m3/h) [l/s] Vmin (m3/h) [l/s] Lwa [dB(A)] Apt (Pa) P (kg/m3) DS (%) FQ (%) Vmax (m/s) x (m) y (m) x+y (m) Vmittel (m/s) Xkr (m) ATo (K) Ceiling air diffuser type CPL-Z (supply air) with on-site perforated ceiling panel - FQ = 16.2% (RG-L15; 02.5) Supply air volume Return air volume Minimum volume A-weighted sound power level Total pressure loss Density Damper position Free cross-section Maximum end velocity of jet horizontal throw vertical throw horizontal + vertical throw Average end...
Open the catalog to page 12
Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Order code CPL I Sample CPL-E-Z-5-600-AL-K000 Ceiling air diffuser type CPL | only ceiling air diffuser | supply air | NW 500| ceiling panel width 600 mm | aluminium painted to the RAL colour 9005 (black) | without connection elbow ORDER DETAILS 01 - Type CPL = ceiling air diffuser CPL 02 - Model E = only ceiling air diffuser 03 - Air throw Z = supply air (standard), with central disc 04 - Nominal size of intake funnel 3 = NW 300 05 - Ceiling panel width 300 = Ceiling panel width 300 mm (not possible for NW 500) 312 = Ceiling panel width 312...
Open the catalog to page 13
Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Order code SK I Sample SK-R-71-Z-500-OM-SV-DK1-GD1-VME0-ROB0-I0-KHS-SDS-S1 Plenum box, square design | for round air diffusers with round diffuser support | air diffuser CPL | supply air | NW 500 | without mounting | galvanised sheet steel | with damper | with rubber lip seal | without volumetric flow meter | without ROB version | without box insulation | standard height of plenum box | standard spigot diameter | 1 lateral spigot ORDER DETAILS 01 - Type SK = plenum box, square design 02 - Model R = for round air diffusers with round diffuser...
Open the catalog to page 14
Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Specification text I Ceiling air diffuser type CPL for supply and return air for use in rooms from 2.6 to 4 m high. Highly inductive air diffuser, air velocity and temperature difference of the supply air jet are effectively reduced. The stable air jet and high induction mean that the CPL ceiling air diffuser can be used in cooling mode up to ATO < -10 K. Consists of an adaptor plate and intake funnel made of aluminium painted to the RAL colour RAL 9005 (black). With supply air model additionally with central disc made of galvanised sheet...
Open the catalog to page 15All SCHAKO KG catalogs and technical brochures
-
CNVA
32 Pages
-
KGF Compact Filter Grille
9 Pages
-
AUDIX
2 Pages
-
DISA
4 Pages
-
UC-OH²
2 Pages
-
IGA
2 Pages
-
CDD
2 Pages
-
FBS
18 Pages
-
MINOPAB
6 Pages
-
PIL
23 Pages
-
MWS / MWK
23 Pages
-
ERK-SO
43 Pages
-
BKSYS
18 Pages
-
MINODSA
6 Pages
-
DKA
6 Pages
-
LAQ
11 Pages
-
VMPR/VMPQ
29 Pages
-
BKA-EN
79 Pages
-
AUDIX®
25 Pages
-
VREX
26 Pages
-
VQEX
17 Pages
-
VPEX
18 Pages
-
SVA-FS
11 Pages
-
NRWG
22 Pages
-
COMBIDSC
26 Pages
-
DSCXL
17 Pages
-
DSCU
18 Pages
-
DSCPL
16 Pages
-
DSCP
15 Pages
-
DSC
37 Pages
-
DO
10 Pages
-
VRAQ
46 Pages
-
UEKU
6 Pages
-
UEK
6 Pages
-
SS-K
6 Pages
-
DQJP
9 Pages
-
VOLKOM
6 Pages
-
DQJ
38 Pages
-
ALPETY
16 Pages
-
CTT
23 Pages
-
STV
8 Pages
-
KWB
19 Pages
-
GREENKIT
20 Pages
-
FKU
31 Pages
-
FKF
29 Pages
-
SGA
5 Pages
-
DBB
27 Pages
-
TVO
8 Pages
-
AL
23 Pages
-
SVA-FF
15 Pages
-
RF Return air filter grille
7 Pages
-
NBS
34 Pages
-
MKAR_MKAQ
13 Pages
-
KF
4 Pages
-
JK
16 Pages
-
HK
16 Pages
-
Lint Separator FLARE
13 Pages
-
FLAQ
11 Pages
-
FKW
28 Pages
-
FG
14 Pages
-
ERK-MB
38 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
CNV
29 Pages
-
BKP-EN Fire damper
40 Pages
-
BKA-UE
35 Pages
-
BAK-250 Fire protection unit
17 Pages
-
BAK-240
16 Pages
-
Aquaris-Silent
38 Pages
-
Aquaris_KWB
20 Pages
-
DISA-W
43 Pages
-
PILB/PILBR
33 Pages
-
DAV
19 Pages
-
4DE
18 Pages
-
4DF
13 Pages
-
DQC
16 Pages
-
DQDL
16 Pages
-
IDA
21 Pages
-
IKA
23 Pages
-
ZMD
17 Pages
-
DQF
15 Pages
-
DQJF
12 Pages
-
DQJA/DQJR
10 Pages
-
DQJSL
17 Pages
-
DQJSLC
17 Pages
-
DHV
18 Pages
-
DSARR
7 Pages
-
QA
30 Pages
-
PUSH
23 Pages
-
WQA
12 Pages
-
DSX-XXL
23 Pages
-
AUDIX®-ÜSG
13 Pages
-
SIA
7 Pages
-
SAR/SAQ/SARP
13 Pages
-
WDA
32 Pages
-
KGRR
17 Pages
-
DBBRR
11 Pages
-
WGARR
7 Pages
-
WGA
29 Pages
-
DKAPPs
6 Pages
-
EBE/EBP
52 Pages
-
VRAPPs
20 Pages
-
VRAR
52 Pages
-
MAK
15 Pages
-
DISA-Family
4 Pages
-
RMS
11 Pages
-
EasyBus
24 Pages
-
TSR
5 Pages
-
RS-F
7 Pages
-
RS
15 Pages
-
VLV
31 Pages
-
VARS
26 Pages
-
VAQS
19 Pages
-
VAS
26 Pages
-
PIANO
27 Pages
-
MBM
10 Pages
-
MBE/MBP
27 Pages
-
DKG
6 Pages
-
ALAS-P
5 Pages
-
ALAS-F 125
6 Pages
-
ALAS
10 Pages
-
ALA-SO
4 Pages
-
ALA-R
4 Pages
-
ALA
4 Pages
-
LL
7 Pages
-
RR-Complete
41 Pages
-
DBBR
6 Pages
-
PA
32 Pages
-
LK
12 Pages
-
IB-R
15 Pages
-
IB-Q
21 Pages
-
KG
19 Pages
-
BSG
19 Pages
-
DSX-XXL-W
25 Pages
-
AUDIX®-AW
20 Pages
-
DSX
25 Pages
-
MINODSX
6 Pages
-
MINODSA
6 Pages
-
DSA
15 Pages
-
COMBIPIL
11 Pages
-
COMBIDQJ
11 Pages
-
MINOPAB
6 Pages
-
BDA
11 Pages
-
SPB
10 Pages
-
CULTRA-Studioline
24 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
AQUARIS SILENT
38 Pages
-
NBS
24 Pages
-
CNV
29 Pages
-
CNVA
32 Pages
-
JK-LP/JK-LU
15 Pages
-
HKP / HKU
16 Pages
-
FKW
16 Pages
-
FLARE
13 Pages
-
RF
7 Pages
-
KGF
9 Pages
-
SVA-FF
8 Pages
-
BKA-Ü
35 Pages
-
BSK-RPR
60 Pages
-
BKP-EN
40 Pages
-
BAK-240
6 Pages
-
BAK-250
14 Pages
-
KF
4 Pages