Technical documentation SCHAKO | Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen
Open the catalog to page 1Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Function and use I Processing FUNCTION AND USE CPL-E-... CPL-...-Z-... CPL-...-A-... CPL-...-3-... CPL-...-5-... CPL-...-300-... CPL-...-312-... CPL-...-600-... CPL-...-625-... The ceiling air diffuser type CPL for supply and return air is suitable for use in rooms from 2.6 to 4 m high. With the supply air model, a special intake funnel behind an existing on-site perforated ceiling panel creates a horizontal air jet below the ceiling for cooling mode and isothermal ventilation mode. A high induction is achieved while the velocity and temperature...
Open the catalog to page 2Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Dimensions I CPL-E-... (ceiling air diffuser mounted to the ceiling panel) FQ = 16.2 % (RG-L15; 02.5 mm) FQ = 25.0 % (RV-L6; 02.1 mm) DPB = ceiling panel width DPL = ceiling panel length - = not possible Construction subject to change No return possible Version: 2020-03-24 | Page 3
Open the catalog to page 3TECHNICAL DOCUMENTATION Dimensions of accessories I DIMENSIONS OF ACCESSORIES Plenum box (-SK) SK-...-S1 (standard), lateral spigot external Rubber seal (made of EPDM) CPL CPL and SK are not permanently connected to one another. SK-...-S0, spigot from above external Air diffuser plate (for supply air model only) With the VME1 model, the projection dimension is approx. 102 mm. KHS= standard height of plenum box Special height of plenum box øD + 137 mm, but at least 235 mm. Spigot position - 1 spigot from above (-S0) 1 lateral spigot (-S1) (standard) 2 lateral spigots, offset by 90° (-S2) 2 lateral...
Open the catalog to page 4Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Dimensions of accessories I Connection to flexible duct Lateral spigot spigot from above Connection elbow (-K030/-K045/-K090) according to DIN EN 1506, consisting of a BGE bend made of galvanised sheet steel. Only possible without plenum box! Bend model: - as a pressed BGE bend with an angle degree: a = 30° (-K030) a = 45° (-K045) a = 90° (-K090) Volumetric flow meter (-VME1), for SK Bend supplied lose, inserted and screwed on site, screws provided on site Internal or external insulation (-Ii / -Ia), for SK Construction subject to change No return...
Open the catalog to page 5TECHNICAL DOCUMENTATION Technical data I TECHNICAL DATA Pressure loss and noise level for supply air / with plenum box and damper Damper position (DS): 0% = CLOSED 100% = OPEN Z = supply air with on-site ceiling panel FQ 16.2% (RG-L15; ø2.5) CPL-E-Z-3-…-SK-...-DK1 with on-site ceiling panel FQ 25% (RV-L6; ø2.1) CPL-E-Z-3-…-SK-...-DK1 Construction subject to change No return possible
Open the catalog to page 6TECHNICAL DOCUMENTATION Technical data I for return air / with plenum box and damper Damper position (DS): 0% = CLOSED 100% = OPEN A = return air with on-site ceiling panel FQ 16.2% (RG-L15; ø2.5) CPL-E-A-3-…-SK-...-DK1 with on-site ceiling panel FQ 25% (RV-L6; ø2.1) CPL-E-A-3-…-SK-...-DK1 Construction subject to change No return possible
Open the catalog to page 7TECHNICAL DOCUMENTATION Technical data I for return air / with connection elbow with on-site ceiling panel for supply air / with connection elbow with on-site ceiling panel on-site ceiling panel: FQ 25% = RV-L6; ø2.1 FQ 16.2% = RG-L15; ø2.5 Construction subject to change No return possible
Open the catalog to page 8TECHNICAL DOCUMENTATION Technical data I with on-site ceiling panel FQ 16.2% (RG-L15; ø2.5) with on-site ceiling panel FQ 25% (RV-L6; ø2.1) Construction subject to change No return possible
Open the catalog to page 9TECHNICAL DOCUMENTATION Technical data I Critical throw with on-site ceiling panel FQ 16.2% (RG-L15; ø2.5) with on-site ceiling panel FQ 25% (RV-L6; ø2.1) Construction subject to change No return possible
Open the catalog to page 10TECHNICAL DOCUMENTATION Technical data I Temperature and induction ratios with on-site ceiling panel FQ 16.2% (RG-L15; ø2.5) with on-site ceiling panel FQ 25% (RV-L6; ø2.1) Construction subject to change No return possible
Open the catalog to page 11Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Minimum air volumes I Legend Vzu (m3/h) [l/s] Vab (m3/h) [l/s] Vmin (m3/h) [l/s] Lwa [dB(A)] Apt (Pa) P (kg/m3) DS (%) FQ (%) Vmax (m/s) x (m) y (m) x+y (m) Vmittel (m/s) Xkr (m) ATo (K) Ceiling air diffuser type CPL-Z (supply air) with on-site perforated ceiling panel - FQ = 16.2% (RG-L15; 02.5) Supply air volume Return air volume Minimum volume A-weighted sound power level Total pressure loss Density Damper position Free cross-section Maximum end velocity of jet horizontal throw vertical throw horizontal + vertical throw Average end velocity...
Open the catalog to page 12Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Order code CPL I Sample CPL-E-Z-5-600-AL-K000 Ceiling air diffuser type CPL | only ceiling air diffuser | supply air | NW 500| ceiling panel width 600 mm | aluminium painted to the RAL colour 9005 (black) | without connection elbow ORDER DETAILS 01 - Type CPL = ceiling air diffuser CPL 02 - Model E = only ceiling air diffuser 03 - Air throw Z = supply air (standard), with central disc 04 - Nominal size of intake funnel 3 = NW 300 05 - Ceiling panel width 300 = Ceiling panel width 300 mm (not possible for NW 500) 312 = Ceiling panel width 312 mm...
Open the catalog to page 13Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Order code SK I Sample SK-R-71-Z-500-OM-SV-DK1-GD1-VME0-ROB0-I0-KHS-SDS-S1 Plenum box, square design | for round air diffusers with round diffuser support | air diffuser CPL | supply air | NW 500 | without mounting | galvanised sheet steel | with damper | with rubber lip seal | without volumetric flow meter | without ROB version | without box insulation | standard height of plenum box | standard spigot diameter | 1 lateral spigot ORDER DETAILS 01 - Type SK = plenum box, square design 02 - Model R = for round air diffusers with round diffuser support...
Open the catalog to page 14Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Specification text I Ceiling air diffuser type CPL for supply and return air for use in rooms from 2.6 to 4 m high. Highly inductive air diffuser, air velocity and temperature difference of the supply air jet are effectively reduced. The stable air jet and high induction mean that the CPL ceiling air diffuser can be used in cooling mode up to ATO < -10 K. Consists of an adaptor plate and intake funnel made of aluminium painted to the RAL colour RAL 9005 (black). With supply air model additionally with central disc made of galvanised sheet steel....
Open the catalog to page 1532 Pages
28 Pages
9 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
18 Pages
6 Pages
23 Pages
23 Pages
43 Pages
17 Pages
16 Pages
18 Pages
6 Pages
6 Pages
11 Pages
29 Pages
18 Pages
15 Pages
9 Pages
79 Pages
25 Pages
26 Pages
17 Pages
18 Pages
11 Pages
22 Pages
26 Pages
37 Pages
10 Pages
46 Pages
6 Pages
6 Pages
6 Pages
6 Pages
8 Pages
38 Pages
6 Pages
16 Pages
23 Pages
19 Pages
20 Pages
15 Pages
31 Pages
29 Pages
5 Pages
27 Pages
8 Pages
23 Pages
7 Pages
34 Pages
13 Pages
4 Pages
16 Pages
16 Pages
13 Pages
11 Pages
14 Pages
38 Pages
34 Pages
32 Pages
51 Pages
29 Pages
40 Pages
35 Pages
17 Pages
16 Pages
38 Pages
20 Pages
43 Pages
24 Pages
11 Pages
33 Pages
19 Pages
18 Pages
13 Pages
16 Pages
16 Pages
21 Pages
23 Pages
17 Pages
15 Pages
12 Pages
10 Pages
17 Pages
17 Pages
18 Pages
11 Pages
11 Pages
15 Pages
7 Pages
30 Pages
23 Pages
12 Pages
25 Pages
23 Pages
20 Pages
13 Pages
25 Pages
7 Pages
13 Pages
32 Pages
19 Pages
19 Pages
21 Pages
15 Pages
12 Pages
32 Pages
6 Pages
17 Pages
11 Pages
7 Pages
29 Pages
4 Pages
4 Pages
4 Pages
10 Pages
5 Pages
6 Pages
52 Pages
6 Pages
27 Pages
27 Pages
26 Pages
19 Pages
26 Pages
20 Pages
52 Pages
15 Pages
7 Pages
15 Pages
24 Pages
4 Pages
11 Pages
5 Pages
31 Pages
10 Pages
7 Pages
41 Pages
6 Pages
10 Pages
34 Pages
38 Pages
24 Pages
15 Pages
16 Pages
16 Pages
13 Pages
7 Pages
9 Pages
8 Pages
35 Pages
60 Pages
40 Pages
6 Pages
14 Pages