Technical documentation SCHAKO | Ferdinand Schad KG Steigstrasse 25-27 D-78600 Kolbingen
Open the catalog to page 1COMBIDSC TECHNICAL DOCUMENTATION Function and use | Models FUNCTION AND USE COMBIDSC-2-... COMBIDSC-4-... COMBIDSC-...-ZA COMBIDSC-...-R0 COMBIDSC-...-S0 COMBIDSC-...-P0 COMBIDSC-...-V COMBIDSC -...-S COMBIDSC-...-N COMBIDSC-...-B COMBIDSC-...-ASK COMBIDSC-...-BS... COMBIDSC is a combined slot diffuser for supply and return air in one housing. The slot diffuser consists of supply air slots for introducing the supply air into the room and return air slots for extracting the return air. The introduction of the supply air is carried out by means of high induction via adjustable blades and is suitable...
Open the catalog to page 2COMBIDSC TECHNICAL DOCUMENTATION Mounting | Blade position for air jet MOUNTING Permanent connection (-FV, standard) -- Only possible with plenum box. -- Standard for the models COMBIDSC-R0 / COMBIDSC-S0 and COMBIDSC-P0. -- The slot diffuser is permanently connected to the plenum box. Concealed mounting (-VM) -- Only possible with plenum box. -- Possible for the models COMBIDSC-R0 / COMBIDSC-P0 and COMBIDSC-S0-Z1 / -Z2 (with additional profile). -- Not possible for the models COMBIDSC-S0-Z0 / COMBIDSC-S0-Z3. -- The slot diffuser is screwed to the pole brace in the plenum box housing with concealed...
Open the catalog to page 3COMBIDSC TECHNICAL DOCUMENTATION Processing | Accessories Frame surface -- Natural colour anodised aluminium (-ELOX, standard). -- Painted aluminium: - RAL 9006 (white aluminium) (-9006). - RAL 9010 (white) (-9010). - Aluminium painted to a different RAL colour (at an extra charge) (-xxxx) Blade colour -- Supply air with blade made of plastic material (hard PVC) / return air with perforated blade made of painted sheet steel: - Blade colour similar to RAL 9005 (black, standard) / perforated plate painted to RAL 9005 (black) (-L9005). - Blade colour similar to RAL 9006 (white aluminium, standard)...
Open the catalog to page 4TECHNICAL DOCUMENTATION Dimensions of frame profile | -- Insulation: - Without insulation (-I0) - With box insulation outside (-Ia), thermal insulation at the outside of the plenum box. -- Height of plenum box: - Standard height of plenum box (-KHS) - Height of box in mm, can be freely selected (-xxx) (minimum height = spigot diameter + 47 mm, always with 3 digits) -- Box neck extension: - Standard box neck (-KVS) - Box neck extension in mm, can be freely selected (-xxx) (minimum height = spigot diameter + 47 mm, always with 3 digits) Can only be used with 2-slot models, 4-slot models don't have...
Open the catalog to page 5COMBIDSC TECHNICAL DOCUMENTATION Dimensions of accessories | DIMENSIONS OF ACCESSORIES Plenum box (-ASK-24) Single design (-N) - Length 1000 mm (length of box KL = 993 mm) (-01000-N) - Length 1500 mm (length of box KL = 1493 mm) (-01500-N) - Length in mm, can be freely selected (length of box KL = L -7 mm), possible length L <1000 mm to >400 mm) (-xxxxx-N) Spigot position S0 = spigot from above S1 = lateral spigots on both sides (standard) S2 = lateral spigot on one side Band design (-B) - Length in mm, can be freely selected, as band (-xxxxx-B) (Available lengths according to SCHAKO standard)...
Open the catalog to page 6TECHNICAL DOCUMENTATION Dimensions of accessories | Plenum box with permanent connection (-FV) The slot diffuser is permanently connected to the plenum box. Standard for the models COMBIDSC-R0 / COMBIDSC-S0 and COMBIDSC-P0. With lateral spigots on both sides (-S1) With spigot from above (-S0) COMBIDSC-2-…-ASK-26-…-FV-S0 Section A-A / supply air Section B-B / return air COMBIDSC-4-…-ASK-26-…-FV-S0 Section A-A / supply air Section B-B / return air 2.) For the table of available sizes, see page 8 For diffuser mounting, detail X, see page 11. For detail Y (rubber lip seal), see page 11. For fastening...
Open the catalog to page 7COMBIDSC TECHNICAL DOCUMENTATION Dimensions of accessories | For diffuser mounting, detail X, see page 11. For detail Y (rubber lip seal), see page 11. For fastening details, see page 18. For the band design, see page 15. 1.) Partition plate 2.) Foam Construction subject to change No return possible Version: 2020-07-24 | Page 8
Open the catalog to page 8TECHNICAL DOCUMENTATION Dimensions of accessories | Plenum box with concealed mounting (-VM) The slot diffuser is screwed to the pole brace in the plenum box housing with concealed screws. Possible for the models COMBIDSC-R0 / COMBIDSC-P0 and COMBIDSC-S0-Z1 / -Z2 (with additional profile). Not possible for the models COMBIDSC-S0-Z0 / COMBIDSC-S0-Z3. With lateral spigots on both sides (-S1) With spigot from above (-S0) COMBIDSC-2-…-ASK-26-…-VM-S0 Section A-A / supply air Section B-B / return air COMBIDSC-4-…-ASK-26-…-VM-S1 Section C-C COMBIDSC-4-…-ASK-26-…-VM-S0 Section A-A / supply air Section...
Open the catalog to page 9COMBIDSC TECHNICAL DOCUMENTATION Dimensions of accessories | With lateral spigot on one side (-S2) COMBIDSC-2-...-ASK-26-...-VM-S2 Section D-D / supply air Section E-E / return air For diffuser mounting, detail X, see page 11. For detail Y (rubber lip seal), see page 11. For fastening details, see page 18. For the band design, see page 15. EOB = installation opening width EOL = installation opening length 1.) Partition plate 2.) Foam Construction subject to change No return possible
Open the catalog to page 10TECHNICAL DOCUMENTATION Dimensions of accessories | Damper (-DK1/-DK2), for ASK -DK1, lateral connection on both sides (-S1, standard) Detail X with long hole ø6.5x10 (-E0, standard): A-A (without slot diffuser) M6 / on site on site with riveting nut M4 (-EM, at an extra charge): At an extra charge, the plenum boxes can be fitted with M4 riveting nuts to facilitate ceiling mounting. M4 / on site -DK1, lateral connection on one side (-S2) -DK2, connection from above (-S0, with cable-operated adjustment) Rubber lip seal (-GD1), for ASK Detail Y Construction subject to change No return possible
Open the catalog to page 11TECHNICAL DOCUMENTATION Dimensions of accessories | Only possible without plenum box. Suitable for all frame profiles (-R0 / -S0 / -P0). Mounting only possible with clamp strap (-KB, standard) or counter pole brace (-GT). Models: - Without additional profile (-Z0). - With additional profile Z I (-Z1): connection of ceiling panels - With additional profile Z II (-Z2): connection of panelled ceilings - With additional profile Z III (-Z3): connection of ceiling panels. Additional profile Z I (-Z1) COMBIDSC-2 Models: -BS0: without dummy piece (only possible in connection with plenum box). -BS1: with...
Open the catalog to page 1232 Pages
28 Pages
9 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
18 Pages
6 Pages
23 Pages
23 Pages
43 Pages
17 Pages
16 Pages
18 Pages
6 Pages
6 Pages
11 Pages
29 Pages
18 Pages
15 Pages
9 Pages
79 Pages
15 Pages
25 Pages
26 Pages
17 Pages
18 Pages
11 Pages
22 Pages
37 Pages
10 Pages
46 Pages
6 Pages
6 Pages
6 Pages
6 Pages
8 Pages
38 Pages
6 Pages
16 Pages
23 Pages
19 Pages
20 Pages
15 Pages
31 Pages
29 Pages
5 Pages
27 Pages
8 Pages
23 Pages
7 Pages
34 Pages
13 Pages
4 Pages
16 Pages
16 Pages
13 Pages
11 Pages
14 Pages
38 Pages
34 Pages
32 Pages
51 Pages
29 Pages
40 Pages
35 Pages
17 Pages
16 Pages
38 Pages
20 Pages
43 Pages
24 Pages
11 Pages
33 Pages
19 Pages
18 Pages
13 Pages
16 Pages
16 Pages
21 Pages
23 Pages
17 Pages
15 Pages
12 Pages
10 Pages
17 Pages
17 Pages
18 Pages
11 Pages
11 Pages
15 Pages
7 Pages
30 Pages
23 Pages
12 Pages
25 Pages
23 Pages
20 Pages
13 Pages
25 Pages
7 Pages
13 Pages
32 Pages
19 Pages
19 Pages
21 Pages
15 Pages
12 Pages
32 Pages
6 Pages
17 Pages
11 Pages
7 Pages
29 Pages
4 Pages
4 Pages
4 Pages
10 Pages
5 Pages
6 Pages
52 Pages
6 Pages
27 Pages
27 Pages
26 Pages
19 Pages
26 Pages
20 Pages
52 Pages
15 Pages
7 Pages
15 Pages
24 Pages
4 Pages
11 Pages
5 Pages
31 Pages
10 Pages
7 Pages
41 Pages
6 Pages
10 Pages
34 Pages
38 Pages
24 Pages
15 Pages
16 Pages
16 Pages
13 Pages
7 Pages
9 Pages
8 Pages
35 Pages
60 Pages
40 Pages
6 Pages
14 Pages