Catalog excerpts

11/01 - 2 Construction subject to change. Version: 05.04.2013 No return possible!
Open the catalog to page 2
Fan Coil Unit Aquaris Silent Description The Aquaris Silent fan coil units are air-conditioners that are especially designed for the decentralised use, for heating or cooling with circulating air. The fan coil units guide the air to be treated through the heat exchanger where it can be heated or cooled in a particularly energy-efficient way. They are used to bring the air quickly to the desired temperature and require only small heating or cooling surfaces. The optimised heat transmission allow lower supply temperatures during heating. And higher supply temperatures during cooling. This...
Open the catalog to page 3
Fan Coil Unit Aquaris Silent Condensate pan The condensate pan can be mounted horizontally or vertically and serves for the collection of the condensate water below the cooling register. The pan is made of galvanised steel and has a thermal insulation (polyethylene with a thickness of 3 mm) to avoid the formation of condensation water. The condensation water outlet is located on the same side as the hydraulic connections and can be connected to the on-site drain system. Motorised fan The motorised fan consists of double-sided intake-operation, dynamically balanced centrifugal blowers with...
Open the catalog to page 4
Fan Coil Unit Aquaris SilentModels, dimensions and weights Dimensions and weights Base unit Housing (optional accessories) A= cold water outlet (cylindrical internal thread, EN 10226-1 Rp 1/2) B= cold water outlet (cylindrical internal thread, EN 10226-1 Rp 1/2) C= cold water outlet (cylindrical internal thread, EN 10226-1 Rp 1/2) D= cold water outlet (cylindrical internal thread, EN 10226-1 Rp 1/2) E = Condensate drain DN16 mm (external) G1 = Weight of the base unit G2 = Weight of the base unit, including device casing To avoid deposits and corrosion, the water quality for filling the...
Open the catalog to page 5
Fan Coil Unit Aquaris Silent Models Horizontal installation with hydraulic connection on the right -H...-R Horizontal installation with hydraulic connection on the left -H...-L Vertical installation with hydraulic connection on the right -V...-R Vertical installation with hydraulic connection on the left -V...-L Vertical model This unit was especially developed for wall mounting. Horizontal model Its compact size and low height make the Aquaris Silent fan coil unit an ideal solution for installation in false ceilings and floors, also allowing an open installation suspended from the ceiling....
Open the catalog to page 6
Fan Coil Unit Aquaris Silent Electric connections Electric connection diagram (SP series) Cooling valve Condensate pump Thermo contact Thermo contact Heating valve Connect the fan coil unit to the earthing cable. Interrupt the power supply, before carrying out any electrical connection work. SCHAKO cannot be held liable for faulty electrical connections or incorrectly dimensioned connecting cables. Stage 2 Stage 3 Stage 4 Stage 5 Stage 6 Condensate pump Heating valve Cooling valve Electric connection diagram (EC series) 11/01 - 7 Construction subject to change. Version: 05.04.2013 No return...
Open the catalog to page 7
Fan Coil Unit Aquaris Silent Wiring thermo contact, overload protection, operational and fault message (SP series) ON-SITE Room controller Yellow Green White (*) White (*) Blue Brown Black Grey Purple Orange Red Blue Brown Yellow / Green Wiring thermo contact, overload protection, operational and fault message (EC series) ON-SITE Room controller Connection depending on the signal type Yellow / Green Brown White (*) = potential-free thermo contact as overload protection for motor, to be provided on-site 11/01 - 8 Construction subject to change. Version: 05.04.2013 No return possible!
Open the catalog to page 8
Fan Coil Unit Aquaris Silent Circuit diagram (with thermo contact) 1 speed switch + 2 or more fan coils (SP series) ON-SITE Speed switch Yellow Green Yellow Green White (*) White (*) Blue Brown Black Grey Purple Orange Red Yellow/ Green White (*) White (*) Blue Brown Black Grey Purple Orange Red Yellow/ Green White (*) = potential-free thermo contact as overload protection for motor, to be provided on-site 11/01 - 9 Construction subject to change. Version: 05.04.2013 No return possible!
Open the catalog to page 9
Fan Coil Unit Aquaris Silent Circuit diagram (with thermo contact) 1 speed switch + 2 or more fan coils (EC series) ON-SITE N L Room controller Yellow / Green Brown Connection depending on the signal type Yellow / Green Brown 11/01 - 10 Construction subject to change. Version: 05.04.2013 No return possible!
Open the catalog to page 10
Fan Coil Unit Aquaris Silent Quick selection diagrams SP series Total cooling capacity (4-pipe system) (1) (see conditions on Page °15) 8,0 7,5 7,0 6,5 Total heating capacity (4-pipe system) (1) (see conditions on Page °15) cooling and heating capacities at speed level 1-6 11/01 - 11 Construction subject to change. Version: 05.04.2013 No return possible
Open the catalog to page 11
Fan Coil Unit Aquaris Silent EC series Total heating capacity (2-pipe system) (2) Total cooling capacity (2-pipe system) (2) Total cooling capacity (4-pipe system) (2) (see conditions on Page °16) Total heating capacity (4-pipe system) (2) (see conditions on Page °16) (2) cooling and heating capacities at 1-10V Construction subject to change.
Open the catalog to page 12
ICHAKO Fan Coil Unit Aquaris Silent Technical data Nominal capacity 2-pipe systems SP series Calculations with filter G2 (1) Measured at 0 Pa of available pressure (2) Air inlet temperature = 27°C, water inlet temperature = 7°C, temperature difference = 5°C (3) Air inlet temperature = 20°C, water inlet temperature= 50°C, same water throughput as in cooling (2)
Open the catalog to page 13
Fan Coil Unit Aquaris SilentEC series Calculations with filter G2 (1) Measured at 0 Pa of available pressure (2) Air inlet temperature = 27°C, water inlet temperature = 7°C, temperature difference = 5°C (3) Air intake temperature = 20°C, water intake temperature= 50°C, same water throughput as in cooling (2) Version: 05.04.2013 Construction subject to change. No return possible!
Open the catalog to page 14
Fan Coil Unit Aquaris Silent Nominal capacity 4-pipe systems SP series Calculations with filter G2 (1) Measured at 0 Pa of available pressure (2) Air inlet temperature = 27°C, water inlet temperature = 7°C, temperature difference = 5°C (3) Air inlet temperature = 20°C, water inlet temperature = 70°C, temperature difference = 10°C Construction subject to change.
Open the catalog to page 15All SCHAKO KG catalogs and technical brochures
-
CNVA
32 Pages
-
KGF Compact Filter Grille
9 Pages
-
AUDIX
2 Pages
-
DISA
4 Pages
-
UC-OH²
2 Pages
-
IGA
2 Pages
-
CDD
2 Pages
-
FBS
18 Pages
-
MINOPAB
6 Pages
-
PIL
23 Pages
-
MWS / MWK
23 Pages
-
ERK-SO
43 Pages
-
BKSYS
18 Pages
-
MINODSA
6 Pages
-
DKA
6 Pages
-
LAQ
11 Pages
-
VMPR/VMPQ
29 Pages
-
BKA-EN
79 Pages
-
CPL
15 Pages
-
AUDIX®
25 Pages
-
VREX
26 Pages
-
VQEX
17 Pages
-
VPEX
18 Pages
-
SVA-FS
11 Pages
-
NRWG
22 Pages
-
COMBIDSC
26 Pages
-
DSCXL
17 Pages
-
DSCU
18 Pages
-
DSCPL
16 Pages
-
DSCP
15 Pages
-
DSC
37 Pages
-
DO
10 Pages
-
VRAQ
46 Pages
-
UEKU
6 Pages
-
UEK
6 Pages
-
SS-K
6 Pages
-
DQJP
9 Pages
-
VOLKOM
6 Pages
-
DQJ
38 Pages
-
ALPETY
16 Pages
-
CTT
23 Pages
-
STV
8 Pages
-
KWB
19 Pages
-
GREENKIT
20 Pages
-
FKU
31 Pages
-
FKF
29 Pages
-
SGA
5 Pages
-
DBB
27 Pages
-
TVO
8 Pages
-
AL
23 Pages
-
SVA-FF
15 Pages
-
RF Return air filter grille
7 Pages
-
NBS
34 Pages
-
MKAR_MKAQ
13 Pages
-
KF
4 Pages
-
JK
16 Pages
-
HK
16 Pages
-
Lint Separator FLARE
13 Pages
-
FLAQ
11 Pages
-
FKW
28 Pages
-
FG
14 Pages
-
ERK-MB
38 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
CNV
29 Pages
-
BKP-EN Fire damper
40 Pages
-
BKA-UE
35 Pages
-
BAK-250 Fire protection unit
17 Pages
-
BAK-240
16 Pages
-
Aquaris_KWB
20 Pages
-
DISA-W
43 Pages
-
PILB/PILBR
33 Pages
-
DAV
19 Pages
-
4DE
18 Pages
-
4DF
13 Pages
-
DQC
16 Pages
-
DQDL
16 Pages
-
IDA
21 Pages
-
IKA
23 Pages
-
ZMD
17 Pages
-
DQF
15 Pages
-
DQJF
12 Pages
-
DQJA/DQJR
10 Pages
-
DQJSL
17 Pages
-
DQJSLC
17 Pages
-
DHV
18 Pages
-
DSARR
7 Pages
-
QA
30 Pages
-
PUSH
23 Pages
-
WQA
12 Pages
-
DSX-XXL
23 Pages
-
AUDIX®-ÜSG
13 Pages
-
SIA
7 Pages
-
SAR/SAQ/SARP
13 Pages
-
WDA
32 Pages
-
KGRR
17 Pages
-
DBBRR
11 Pages
-
WGARR
7 Pages
-
WGA
29 Pages
-
DKAPPs
6 Pages
-
EBE/EBP
52 Pages
-
VRAPPs
20 Pages
-
VRAR
52 Pages
-
MAK
15 Pages
-
DISA-Family
4 Pages
-
RMS
11 Pages
-
EasyBus
24 Pages
-
TSR
5 Pages
-
RS-F
7 Pages
-
RS
15 Pages
-
VLV
31 Pages
-
VARS
26 Pages
-
VAQS
19 Pages
-
VAS
26 Pages
-
PIANO
27 Pages
-
MBM
10 Pages
-
MBE/MBP
27 Pages
-
DKG
6 Pages
-
ALAS-P
5 Pages
-
ALAS-F 125
6 Pages
-
ALAS
10 Pages
-
ALA-SO
4 Pages
-
ALA-R
4 Pages
-
ALA
4 Pages
-
LL
7 Pages
-
RR-Complete
41 Pages
-
DBBR
6 Pages
-
PA
32 Pages
-
LK
12 Pages
-
IB-R
15 Pages
-
IB-Q
21 Pages
-
KG
19 Pages
-
BSG
19 Pages
-
DSX-XXL-W
25 Pages
-
AUDIX®-AW
20 Pages
-
DSX
25 Pages
-
MINODSX
6 Pages
-
MINODSA
6 Pages
-
DSA
15 Pages
-
COMBIPIL
11 Pages
-
COMBIDQJ
11 Pages
-
MINOPAB
6 Pages
-
BDA
11 Pages
-
SPB
10 Pages
-
CULTRA-Studioline
24 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
AQUARIS SILENT
38 Pages
-
NBS
24 Pages
-
CNV
29 Pages
-
CNVA
32 Pages
-
JK-LP/JK-LU
15 Pages
-
HKP / HKU
16 Pages
-
FKW
16 Pages
-
FLARE
13 Pages
-
RF
7 Pages
-
KGF
9 Pages
-
SVA-FF
8 Pages
-
BKA-Ü
35 Pages
-
BSK-RPR
60 Pages
-
BKP-EN
40 Pages
-
BAK-240
6 Pages
-
BAK-250
14 Pages
-
KF
4 Pages