Catalog excerpts

Compact Air-Conditioning ModuleModel Aquaris KWB Ferdinand Schad KG SteigstraGe 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63 - 980 - 0 Fax +49 (0) 74 63 - 980 - 200 info@schako.de www.schako.de
Open the catalog to page 1
11/15 - 2 Construction subject to change. Version: 30.07.2012 No return possible!
Open the catalog to page 2
“HAk#Compact Air-Conditioning Module Model Aquaris KWB Description The compact air-conditioning module Aquaris Silent has been designed for installation in suspended corridor ceilings for the air-conditioning of office rooms. The arrangement of supply air and return air grilles on one side of the room creates a rolling motion with an optimum air flow through the room. The plug-in compact air-conditioning module allows a cost-efficient and quick installation in the suspended ceilings of the corridor areas located next to the rooms to be air-conditioned. This allows full utilisation of the...
Open the catalog to page 3
Compact Air-Conditioning Module Model Aquaris KWB Dimensions of accessories Valves VMP46 Three-way valve having a nominal pressure of 16 bar. Brass housing. External thread connections G...B. Provided with manual adjuster. Electrothermal actuator for valve of 2.5 mm nominal stroke. Including motion and position display. Operating mode 24 V DC. - OPEN/CLOSE function or proportional PWM Valve types Actuator STA219 - Actuator 230 V AC - OPEN/CLOSE function or proportional PWM Actuator STA719 - Actuator 24 V AC - OPEN/CLOSE function or proportional PWM Construction subject to change.
Open the catalog to page 6
ICHAKcfCompact Air-Conditioning Module Model Aquaris KWB Room temperature controller for 2-pipe system Model RCC10 Output for On/Off valve actuator Outputs for three-speed fan Control either by room temperature or return air temperature, as desired Automatic heating/cooling mode switchover Standard, Economy, Antifreeze operating modes or OFF Switchover contact input for remote circuit Control parameters selectable Operating voltage AC 230 V B1 = Return air sensor (temperature sensor QAH11.1) B2 = Changeover sensor (temperature sensor QAH11.1 + changeover assembly kit ARG86.3) M1 = 3-speed...
Open the catalog to page 7
Compact Air-Conditioning Module Model Aquaris KWB Room temperature controller for 4-pipe system Model RCC30 Model RDF30 - Outputs for On/Off valve actuators - Outputs for three-speed fan - Control either by room temperature or return air temperature, as desired - Standard, Economy, Antifreeze operating modes or OFF - Operating mode switchover contact input for remote circuit - Control parameters selectable - Operating voltage AC 230 V - Outputs for 2-point valve drives - Outputs for three-speed fan - Control either by room temperature or return air temperature, as desired - Standard,...
Open the catalog to page 8
Compact Air-Conditioning Module Model Aquaris KWB Connection diagram 2-pipe fan coil unit with / without heating element Digital compact room controller for 2-pipe with/without heating element or 4-pipe fan coil units - Proportional PWM outputs for electrothermal valve actuators 230 V AC - Automatic or manual 3-speed fans - Manual or automatic winter/summer (heating/cooling) selector switch (including QAH11.1 sensor) - Three operating modes: Standard, Economy or Standby mode - Digital input: Operating modes selector switch (for motion detector or open window) - Optional input for return air...
Open the catalog to page 9
“"AK#Compact Air-Conditioning Module Model Aquaris KWB Condensate pump Description The condensate pump is used to remove the water of condensation from the cooling register, in case there is not enough gradient towards the on-site drain system. With alarm message (when water height rises above 27 mm). Technical data Power supply Output Rated current Maximum power Thermal protection Alarm contact Safety measure medium Temperature of the medium Ambient temperature Max. flow Max. pressure difference Max. delivery height Pump type Sound level Dimensions Float switch 230 V-50/60 Hz (230 V-50 Hz)...
Open the catalog to page 10
Compact Air-Conditioning Module Model Aquaris KWB Connection scheme / terminal diagram Condensation water pump type 8 FC on-site: (1) Plenum box (2) cable (3) 630 mA fuse P N Connection to earth (4) Solenoid valve C (5) Compressor NC (6) or Important: The pump is equipped with a C & NC / C & NO (reversible) overflow alarm contact (8 A/250 V). The connecting cable must be selected accordingly. The contact can be used, for example, to switch off a cooling system in which there is a risk of condensate overflow (after a detailed check of the customer specification and the resulting electric...
Open the catalog to page 11
Compact Air-Conditioning Module Model Aquaris KWB Technical data Circuit diagrams Wiring thermo contact, overload protection Applies to motorised valve actuators For thermal actuators, terminals 3 and 6 are not used. Construction subject to change.
Open the catalog to page 12
Compact Air-Conditioning Module Model Aquaris KWB Wiring thermo contact, overload protection, operational and fault message on-site L ON / OFF Potential-free contact white white* yellow / green Room Controller 11/15 - 13 Construction subject to change. blue brown black grey violet orange red min. Version: 30.07.2012 No return possible!
Open the catalog to page 13
Compact Air-Conditioning Module Model Aquaris KWB Wiring for parallel operation N Circuit diagram 1 speed switch + 2 or more fan coils (**) Depending on the switching power of the control device KM1 white (*) white (*) yellow C green blue brown brown black grey violet orange red min. yellow / green white (*) white (*) yellow C green blue brown Speed selector switch brown black grey violet orange red min. yellow / green white (*) white (*) yellow C green brown black grey violet orange red min. yellow / green white (*) white (*) yellow C green blue brown brown black grey violet orange red...
Open the catalog to page 14
Compact Air-Conditioning Module Model Aquaris KWB Mounting information Seals Plenum box Flexible connecting piece 1 Suspend plenum box from ceiling and fasten it to the wall with screws. 2 Screw FCU to plenum box with flexible connecting piece and suspend from ceiling sound-decoupled. 3 Screw diffuser to plenum box by means of concealed mounting (-VM). 11/15 - 15 Construction subject to change. Version: 30.07.2012 No return possible!
Open the catalog to page 15All SCHAKO KG catalogs and technical brochures
-
CNVA
32 Pages
-
KGF Compact Filter Grille
9 Pages
-
AUDIX
2 Pages
-
DISA
4 Pages
-
UC-OH²
2 Pages
-
IGA
2 Pages
-
CDD
2 Pages
-
FBS
18 Pages
-
MINOPAB
6 Pages
-
PIL
23 Pages
-
MWS / MWK
23 Pages
-
ERK-SO
43 Pages
-
BKSYS
18 Pages
-
MINODSA
6 Pages
-
DKA
6 Pages
-
LAQ
11 Pages
-
VMPR/VMPQ
29 Pages
-
BKA-EN
79 Pages
-
CPL
15 Pages
-
AUDIX®
25 Pages
-
VREX
26 Pages
-
VQEX
17 Pages
-
VPEX
18 Pages
-
SVA-FS
11 Pages
-
NRWG
22 Pages
-
COMBIDSC
26 Pages
-
DSCXL
17 Pages
-
DSCU
18 Pages
-
DSCPL
16 Pages
-
DSCP
15 Pages
-
DSC
37 Pages
-
DO
10 Pages
-
VRAQ
46 Pages
-
UEKU
6 Pages
-
UEK
6 Pages
-
SS-K
6 Pages
-
DQJP
9 Pages
-
VOLKOM
6 Pages
-
DQJ
38 Pages
-
ALPETY
16 Pages
-
CTT
23 Pages
-
STV
8 Pages
-
KWB
19 Pages
-
GREENKIT
20 Pages
-
FKU
31 Pages
-
FKF
29 Pages
-
SGA
5 Pages
-
DBB
27 Pages
-
TVO
8 Pages
-
AL
23 Pages
-
SVA-FF
15 Pages
-
RF Return air filter grille
7 Pages
-
NBS
34 Pages
-
MKAR_MKAQ
13 Pages
-
KF
4 Pages
-
JK
16 Pages
-
HK
16 Pages
-
Lint Separator FLARE
13 Pages
-
FLAQ
11 Pages
-
FKW
28 Pages
-
FG
14 Pages
-
ERK-MB
38 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
CNV
29 Pages
-
BKP-EN Fire damper
40 Pages
-
BKA-UE
35 Pages
-
BAK-250 Fire protection unit
17 Pages
-
BAK-240
16 Pages
-
Aquaris-Silent
38 Pages
-
DISA-W
43 Pages
-
PILB/PILBR
33 Pages
-
DAV
19 Pages
-
4DE
18 Pages
-
4DF
13 Pages
-
DQC
16 Pages
-
DQDL
16 Pages
-
IDA
21 Pages
-
IKA
23 Pages
-
ZMD
17 Pages
-
DQF
15 Pages
-
DQJF
12 Pages
-
DQJA/DQJR
10 Pages
-
DQJSL
17 Pages
-
DQJSLC
17 Pages
-
DHV
18 Pages
-
DSARR
7 Pages
-
QA
30 Pages
-
PUSH
23 Pages
-
WQA
12 Pages
-
DSX-XXL
23 Pages
-
AUDIX®-ÜSG
13 Pages
-
SIA
7 Pages
-
SAR/SAQ/SARP
13 Pages
-
WDA
32 Pages
-
KGRR
17 Pages
-
DBBRR
11 Pages
-
WGARR
7 Pages
-
WGA
29 Pages
-
DKAPPs
6 Pages
-
EBE/EBP
52 Pages
-
VRAPPs
20 Pages
-
VRAR
52 Pages
-
MAK
15 Pages
-
DISA-Family
4 Pages
-
RMS
11 Pages
-
EasyBus
24 Pages
-
TSR
5 Pages
-
RS-F
7 Pages
-
RS
15 Pages
-
VLV
31 Pages
-
VARS
26 Pages
-
VAQS
19 Pages
-
VAS
26 Pages
-
PIANO
27 Pages
-
MBM
10 Pages
-
MBE/MBP
27 Pages
-
DKG
6 Pages
-
ALAS-P
5 Pages
-
ALAS-F 125
6 Pages
-
ALAS
10 Pages
-
ALA-SO
4 Pages
-
ALA-R
4 Pages
-
ALA
4 Pages
-
LL
7 Pages
-
RR-Complete
41 Pages
-
DBBR
6 Pages
-
PA
32 Pages
-
LK
12 Pages
-
IB-R
15 Pages
-
IB-Q
21 Pages
-
KG
19 Pages
-
BSG
19 Pages
-
DSX-XXL-W
25 Pages
-
AUDIX®-AW
20 Pages
-
DSX
25 Pages
-
MINODSX
6 Pages
-
MINODSA
6 Pages
-
DSA
15 Pages
-
COMBIPIL
11 Pages
-
COMBIDQJ
11 Pages
-
MINOPAB
6 Pages
-
BDA
11 Pages
-
SPB
10 Pages
-
CULTRA-Studioline
24 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
AQUARIS SILENT
38 Pages
-
NBS
24 Pages
-
CNV
29 Pages
-
CNVA
32 Pages
-
JK-LP/JK-LU
15 Pages
-
HKP / HKU
16 Pages
-
FKW
16 Pages
-
FLARE
13 Pages
-
RF
7 Pages
-
KGF
9 Pages
-
SVA-FF
8 Pages
-
BKA-Ü
35 Pages
-
BSK-RPR
60 Pages
-
BKP-EN
40 Pages
-
BAK-240
6 Pages
-
BAK-250
14 Pages
-
KF
4 Pages