08/01 - 2 Construction subject to change. Version: 30.10.2018 No return possible!
Open the catalog to page 2Weather Protection Grille ALAS Description External air intake or return air grille with fixed, rain-repellent blades and back-fitted wire mesh grid. Mounting holes drilled as standard. On request, all designs with mounting frames made of angular 30/30/3 steel are primed. ALAS with self-regulating heating strip A better way of preventing ice formation is the installation of a self-regulating heating strip. It is a heating strip that adapts the heating output to the environment at any position of the grille. Available in any length, rated capacity max. 36 W/m. It can be used up to -8 °C and 80%...
Open the catalog to page 3Weather Protection Grille ALASModels and dimensions Dimensions Installation arrangement for sectioned design at height > 1995 1.) from height or width > 1600, 3 fixing holes per side 2.) additional holes for widths > 900 For a height of > 1995 two standard surrounding air suction grilles must be installed, one on top the other. Installation height (EMH): "EMH=(H1xa)-(2x45)+15" a = Number of grilles For a width of > 2000 two standard surrounding air suction grilles must be installed next to each other. Installation width (EMB): "EMB=(B1xa)-(2x45)+15“ a = Number of grilles Construction subject...
Open the catalog to page 4Weather Protection Grille ALAS The illustration shows the grilles as continuous run. Any number of grilles can be installed next to each other. Expansion joints have to be allowed when fixing air suction grilles on site. On request, a mounting frame made of angular steel 30/30/3 can be delivered primed (at an extra charge). 1.) from a height or width > 1600, 3 fixing holes per side 2.) additional holes for widths > 900 Mounting frame for band design *DQ^0Q^Dfl. Installation in front of the wall ALAS / ALAS-Cu ALAS-Alu Number of wall anchors for mounting frame Height: H < 1000 = 2 wall anchors...
Open the catalog to page 5Weather Protection Grille ALAS Fixing lugs (not removable from the outside) Mounting height (EMH) + +10 Mounting height (EMH) Mounting detail ALAS with mounting frame Height one-piece Sectioned height Sectioning of fixing lug Height: H < 800 ⇒ 800 < H < 1100 ⇒ 1100 < H < 1800 ⇒ 1800 < H < 2000 ⇒ Wall anchor Wall anchor Sectioned width ⇒ 2 fixing lugs per side ⇒ 2 fixing lugs per side ⇒ 2 fixing lugs per side ⇒ 3 fixing lugs per side Width: B < 900 ⇒ b= ---- ⇒ no fixing lug 900 < B < 1200 ⇒ b=140 ⇒ 2 fixing lugs per side 1200 < B < 1800 ⇒ b=230 ⇒ 2 fixing lugs per side 1800 < B < 2000 ⇒ b=230...
Open the catalog to page 6Weather Protection Grille ALAS ALAS with heating strip Technical details regarding the heating strip Structure 1. 1.2 mm2 multi-strand copper conductor 2. Self-regulating, semi-conductive heating element 3. 0.7 mm electrical insulation made of modified polyolefin 4. Protection mesh made of galvanised copper leads 5. Outer casing made of modified polyolefin Thermal safety class 0 according to VDE 0721 Part 2 E § 10 Technical data Nominal voltage 230 V Rated power - Ice-water: at 0°C 36W/m max. resistance of protective mesh 0.0152 W/m max. permitted surrounding temperature - switched on + 65 °C...
Open the catalog to page 7Weather Protection Grille ALAS ALAS with "top" heating strip Technical details regarding the "top" heating strip Structure 1. 1.4 mm2 multi-strand copper conductor 2. Self-regulating, semi-conductive heating element 3. Insulation made of fluoro polymer 4. Protection mesh made of galvanised copper leads 5. Outer casing made of fluoro polymer Temperature classification T4 in accordance with European standard EN 50014. Technical data Nominal voltage 230 V Rated power - Air: at 10°C 64W/m max. resistance of protective mesh 0.01 Ω/m max. temperature of use (permanently switched on) + 110 °C Note Per...
Open the catalog to page 8Weather Protection Grille ALASTechnical data Pressure loss and noise level Area correction FQband = FQ - (KF x number of webs) Construction subject to change.
Open the catalog to page 9Weather Protection Grille ALAS Circuit diagram ALAS (with heating strip) ALAS (with "top" heating strip) Lwa [dB(A)] = A-weighted sound power level, relative to 1 m2 (Lwa = (Lwa / m2) + KF) vstirn (m/s) = Intake velocity, relative to (H - 80) x B F (m2) = Cross-section area, relative to (H - 80) x B KF (m) = Surface area correction factor FQ (m2) = free cross-section per running metre D (mm) = diameter of the mesh wire Specification texts External air intake or return air grille with fixed, rain-repellent blades and back-fitted wire mesh grid. - Frame and blades from galvanised sheet steel, with...
Open the catalog to page 1032 Pages
28 Pages
9 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
18 Pages
6 Pages
23 Pages
23 Pages
43 Pages
17 Pages
16 Pages
18 Pages
6 Pages
6 Pages
11 Pages
29 Pages
18 Pages
15 Pages
9 Pages
79 Pages
15 Pages
25 Pages
26 Pages
17 Pages
18 Pages
11 Pages
22 Pages
26 Pages
37 Pages
10 Pages
46 Pages
6 Pages
6 Pages
6 Pages
6 Pages
8 Pages
38 Pages
6 Pages
16 Pages
23 Pages
19 Pages
20 Pages
15 Pages
31 Pages
29 Pages
5 Pages
27 Pages
8 Pages
23 Pages
7 Pages
34 Pages
13 Pages
4 Pages
16 Pages
16 Pages
13 Pages
11 Pages
14 Pages
38 Pages
34 Pages
32 Pages
51 Pages
29 Pages
40 Pages
35 Pages
17 Pages
16 Pages
38 Pages
20 Pages
43 Pages
24 Pages
11 Pages
33 Pages
19 Pages
18 Pages
13 Pages
16 Pages
16 Pages
21 Pages
23 Pages
17 Pages
15 Pages
12 Pages
10 Pages
17 Pages
17 Pages
18 Pages
11 Pages
11 Pages
15 Pages
7 Pages
30 Pages
23 Pages
12 Pages
25 Pages
23 Pages
20 Pages
13 Pages
25 Pages
7 Pages
13 Pages
32 Pages
19 Pages
19 Pages
21 Pages
15 Pages
12 Pages
32 Pages
6 Pages
17 Pages
11 Pages
7 Pages
29 Pages
4 Pages
4 Pages
4 Pages
5 Pages
6 Pages
52 Pages
6 Pages
27 Pages
27 Pages
26 Pages
19 Pages
26 Pages
20 Pages
52 Pages
15 Pages
7 Pages
15 Pages
24 Pages
4 Pages
11 Pages
5 Pages
31 Pages
10 Pages
7 Pages
41 Pages
6 Pages
10 Pages
34 Pages
38 Pages
24 Pages
15 Pages
16 Pages
16 Pages
13 Pages
7 Pages
9 Pages
8 Pages
35 Pages
60 Pages
40 Pages
6 Pages
14 Pages