WDA - 2

05/18 - 2 Construction subject to change. Version: 13.02.2020 No return possible!

Open the catalog to page 2
WDA - 3

Long throw nozzle WDA Model WDA-N-... WDA-F-... WDA-W-... WDA-D-... WDA-K-... WDA-R-... Description A horizontal supply air pattern is often required for large, high rooms such as theatres, concert halls, production halls, etc. Long throw nozzles type WDA are particularly suitable for this application. Their low noise level allows a high blow velocity, resulting in correspondingly long throw distances. The nozzles are also well suited to vertical throws. Please note, however, that nozzles which are designed for heating mode can cause draughts in cooling mode. This can be avoided if the...

Open the catalog to page 3
WDA - 4

Long throw nozzle WDAModels and dimensions WDA-W-... WDA-F-... WDA-D-... WDA-K-... WDA-R-... (not possible for NW 031-050 and NW 400) 1.) 3 x indentation for slotted shallow-raised countersunk-head tapping screw DIN ISO 7051 pitch 3.9 Available sizes WDA-N-... / WDA-W-... / WDA-F-... / WDA-D-... / WDA-K-... / WDA-R-... * Larger diameters are also available upon request! Construction subject to change.

Open the catalog to page 4
WDA - 5

Long throw nozzle WDA Dimensions of accessories Swivel head (-SK, NW 050 not possible) The adjustment of the nozzle can be done manually or electrically. WDA-F-. ..-SK-... / WDA-D-. ..-SK-... 1.) 3 x indentation for slotted shallow- raised counter sunk-head tapping screw DIN ISO 7051 pitch 3.9 (6 for NW400) Larger diame :ers are also available upon request! Construction subject to change.

Open the catalog to page 5
WDA - 6

Long throw nozzle WDA Swivel head (-SK, NW 400) The adjustment of the nozzle can be done manually or electrically. WDA-F-400-SK-... / WDA-D-400-SK-... WDA-W-400-SK-... 1.) 6x bore ø8 for mounting on site 05/18 - 6 Construction subject to change.

Open the catalog to page 6
WDA - 7

Long throw nozzle WDAElectric actuator (only available from NW 063) Mounted externally (standard) “AL” = Left-hand design (standard) 0V = nozzles on top Direction of rotation: "R" “AR” = Right-hand design 0V = nozzles on top Direction of rotation "L" For an externally fitted actuator, please make sure that the distance to the ceiling or wall is greater than 10 mm. Construction subject to change.

Open the catalog to page 7
WDA - 8

Long throw nozzle WDAMounted internally (-Al, at an extra charge, NW 400 not possible): 5 "O 1 o * Larger diameters are also available u pon request! For size 400, an actuator cannot be mounted internally! Construction subject to change.

Open the catalog to page 8
WDA - 9

Reduction piece (-RS) (only available for NW 063 - 200) without swivel head / with or without swirl disc WDA-W-...-RS-... with swivel head / with or without swirl disc WDA-W-...-SK-...-RS-... Construction subject to change. Damper (-DV) (only available for NW 400)

Open the catalog to page 9
WDA - 10

Long throw nozzle WDA Cover plate (-BR) (concealed mounting, only NW 063-200 available) Construction subject to change.

Open the catalog to page 10
WDA - 11

Long throw nozzle WDABall impact guard (-BS) WDA-D-.. .-BS-... / WDA-K-...-BS-... Number of fastening holes Construction subject to change.

Open the catalog to page 11
WDA - 12

Long throw nozzle WDA WDA-D-...-SK-. ..-BS-... / WDA-F-.. .-SK-...-BS-... Construction subject to change.

Open the catalog to page 12
WDA - 13

Long throw nozzle WDA WDA-K-...-SK-...-BS-... Construction subject to change.

Open the catalog to page 13
WDA - 14

Long throw nozzle WDA Technical data Pressure loss and noise level WDA-...-031-... / WDA-...-050-... 05/18 - 14 Construction subject to change. Version: 13.02.2020 No return possible!

Open the catalog to page 14
WDA - 15

Long throw nozzle WDAJet angle a NW Correction factor for swirl disc WDA 063 - 200 Construction subject to change.

Open the catalog to page 15
WDA - 16

Long throw nozzle WDA WDA-...-RS-..., with reduction piece Correction factor for swirl disc WDA-. ..-063-. ..-RS-... / WDA-. ..-200-. ..-RS-... Construction subject to change.

Open the catalog to page 16
WDA - 17

Long throw nozzle WDA WDA-...-400-... (without damper) 05/18 - 17 Construction subject to change. Version: 13.02.2020 No return possible!

Open the catalog to page 17
WDA - 18

Long throw nozzle WDAMaximum end velocity of jet WDA-...-031 - 050-... Construction subject to change.

Open the catalog to page 18
WDA - 19

Long throw nozzle WDA Maximum penetration WDA-...-031 - 050-... 05/18 - 19 Construction subject to change. Version: 13.02.2020 No return possible!

Open the catalog to page 19
WDA - 20

Long throw nozzle WDA Model for vertical nozzle mounting for cooling mode Correction factors of the expected average velocity in vertical installation of the nozzles Calculation of the average velocity, relative to the AT for vertically integrated nozzles.Example: WDA-...-200-... at 250 m3/h, mounting height = 9.5 m, AT = - 6 K: Head height = 9.5 m - 1.8 m = 7.7 m y (m) would be 7.7 m according to SCHAKO's design program; since the nozzle is mounted horizontally according to the design program, the y value for vertically integrated nozzles must be entered under x (m)! x = 7.7 m According to...

Open the catalog to page 20
WDA - 21

Version: 13.02.2020 Construction subject to change. No return possible!

Open the catalog to page 21
WDA - 22

Long throw nozzle WDA Temperature ratios WDA-...-031 -050-... 05/18 - 22 Construction subject to change. Version: 13.02.2020 No return possible!

Open the catalog to page 22
WDA - 23

Long throw nozzle WDA Definitions Cooling mode Cooling mode example Assume: NW 100 Construction subject to change.

Open the catalog to page 23
WDA - 24

Long throw nozzle WDA Further data Horizontal throw (free jet) WDA-...-031 - 050-... 05/18 - 24 Construction subject to change. Version: 13.02.2020 No return possible!

Open the catalog to page 24
WDA - 25

Long throw nozzle WDA WDA -...-125 - 200-... 05/18 - 25 Construction subject to change. Version: 13.02.2020 No return possible!

Open the catalog to page 25
WDA - 26

Long throw nozzle WDA Connection diagrams of electric actuators Make Siemens E092 (GLB 331.2.E) Three-point control OPEN/CLOSED control Make Siemens E091 (standard GLB 163.2.E) Steady control Make Siemens E090 (GLB 131.2.E) Three-point control 05/18 - 26 Construction subject to change.

Open the catalog to page 26
WDA - 27

Long throw nozzle WDATechnical data of electric actuators Make Belimo E048 (NM230A-F) Rated voltage: Functional range: Power consumption - Operation: - Idle position: - Dimensioning: Torque (rated torque): Running time: Sound power level: Protection class: Degree of protection: EMC: Low voltage directive: Ambient temperature: AC 100 ... 240 V, 50 / 60 Hz AC 85 ... 265 V 2.5 W @ nominal torque 0.6 W 6 VA Min. 10 Nm at the rated voltage 150 s max. 35 dB (A) II protective insulation IP54 in all mounting positions CE according to 89 / 336 / EEC CE according to 73 / 23 / EEC -30 ... +50°C Rated...

Open the catalog to page 27

All SCHAKO KG catalogs and technical brochures

  1. AUDIX

    2 Pages

  2. DISA

    4 Pages

  3. UC-OH²

    2 Pages

  4. IGA

    2 Pages

  5. CDD

    2 Pages

  6. FBS

    18 Pages

  7. MINOPAB

    6 Pages

  8. PIL

    23 Pages

  9. MWS / MWK

    23 Pages

  10. ERK-SO

    43 Pages

  11. BKSYS

    18 Pages

  12. MINODSA

    6 Pages

  13. DKA

    6 Pages

  14. LAQ

    11 Pages

  15. VMPR/VMPQ

    29 Pages

  16. BKA-EN

    79 Pages

  17. CPL

    15 Pages

  18. AUDIX®

    25 Pages

  19. VREX

    26 Pages

  20. VQEX

    17 Pages

  21. VPEX

    18 Pages

  22. SVA-FS

    11 Pages

  23. NRWG

    22 Pages

  24. COMBIDSC

    26 Pages

  25. DSCXL

    17 Pages

  26. DSCU

    18 Pages

  27. DSCPL

    16 Pages

  28. DSCP

    15 Pages

  29. DSC

    37 Pages

  30. DO

    10 Pages

  31. VRAQ

    46 Pages

  32. UEKU

    6 Pages

  33. UEK

    6 Pages

  34. SS-K

    6 Pages

  35. DQJP

    9 Pages

  36. VOLKOM

    6 Pages

  37. DQJ

    38 Pages

  38. ALPETY

    16 Pages

  39. CTT

    23 Pages

  40. STV

    8 Pages

  41. KWB

    19 Pages

  42. GREENKIT

    20 Pages

  43. FKU

    31 Pages

  44. FKF

    29 Pages

  45. SGA

    5 Pages

  46. DBB

    27 Pages

  47. TVO

    8 Pages

  48. AL

    23 Pages

  49. SVA-FF

    15 Pages

  50. RF

    7 Pages

  51. NBS

    34 Pages

  52. MKAR_MKAQ

    13 Pages

  53. KGF

    11 Pages

  54. KF

    4 Pages

  55. JK

    16 Pages

  56. HK

    16 Pages

  57. FLARE

    13 Pages

  58. FLAQ

    11 Pages

  59. FKW

    28 Pages

  60. FG

    14 Pages

  61. ERK-MB

    38 Pages

  62. DISA-H

    34 Pages

  63. DISA-B

    32 Pages

  64. DISA-601

    41 Pages

  65. DISA-360

    32 Pages

  66. DISA-300

    51 Pages

  67. CNVA

    32 Pages

  68. CNV

    29 Pages

  69. BSK-RPR

    60 Pages

  70. BKP-EN

    40 Pages

  71. BKA-UE

    35 Pages

  72. BAK-250

    17 Pages

  73. BAK-240

    16 Pages

  74. Aquaris-Silent

    38 Pages

  75. Aquaris_KWB

    20 Pages

  76. DISA-W

    43 Pages

  77. PILB/PILBR

    33 Pages

  78. DAV

    19 Pages

  79. 4DE

    18 Pages

  80. 4DF

    13 Pages

  81. DQC

    16 Pages

  82. DQDL

    16 Pages

  83. IDA

    21 Pages

  84. IKA

    23 Pages

  85. ZMD

    17 Pages

  86. DQF

    15 Pages

  87. DQJF

    12 Pages

  88. DQJA/DQJR

    10 Pages

  89. DQJSL

    17 Pages

  90. DQJSLC

    17 Pages

  91. DHV

    18 Pages

  92. DSARR

    7 Pages

  93. QA

    30 Pages

  94. PUSH

    23 Pages

  95. WQA

    12 Pages

  96. DSX-XXL

    23 Pages

  97. AUDIX®-ÜSG

    13 Pages

  98. SIA

    7 Pages

  99. SAR/SAQ/SARP

    13 Pages

  100. KGRR

    17 Pages

  101. DBBRR

    11 Pages

  102. WGARR

    7 Pages

  103. WGA

    29 Pages

  104. DKAPPs

    6 Pages

  105. EBE/EBP

    52 Pages

  106. VRAPPs

    20 Pages

  107. VRAR

    52 Pages

  108. MAK

    15 Pages

  109. DISA-Family

    4 Pages

  110. RMS

    11 Pages

  111. EasyBus

    24 Pages

  112. TSR

    5 Pages

  113. RS-F

    7 Pages

  114. RS

    15 Pages

  115. VLV

    31 Pages

  116. VARS

    26 Pages

  117. VAQS

    19 Pages

  118. VAS

    26 Pages

  119. PIANO

    27 Pages

  120. MBM

    10 Pages

  121. MBE/MBP

    27 Pages

  122. DKG

    6 Pages

  123. ALAS-P

    5 Pages

  124. ALAS-F 125

    6 Pages

  125. ALAS

    10 Pages

  126. ALA-SO

    4 Pages

  127. ALA-R

    4 Pages

  128. ALA

    4 Pages

  129. LL

    7 Pages

  130. RR-Complete

    41 Pages

  131. DBBR

    6 Pages

  132. PA

    32 Pages

  133. LK

    12 Pages

  134. IB-R

    15 Pages

  135. IB-Q

    21 Pages

  136. KG

    19 Pages

  137. BSG

    19 Pages

  138. DSX-XXL-W

    25 Pages

  139. AUDIX®-AW

    20 Pages

  140. DSX

    25 Pages

  141. MINODSX

    6 Pages

  142. MINODSA

    6 Pages

  143. DSA

    15 Pages

  144. COMBIPIL

    11 Pages

  145. COMBIDQJ

    11 Pages

  146. MINOPAB

    6 Pages

  147. BDA

    11 Pages

  148. SPB

    10 Pages

  149. DISA-H

    34 Pages

  150. DISA-601

    41 Pages

  151. DISA-360

    32 Pages

  152. DISA-300

    51 Pages

  153. DISA-B

    32 Pages

  154. AQUARIS SILENT

    38 Pages

  155. NBS

    24 Pages

  156. CNV

    29 Pages

  157. CNVA

    32 Pages

  158. JK-LP/JK-LU

    15 Pages

  159. HKP / HKU

    16 Pages

  160. FKW

    16 Pages

  161. FLARE

    13 Pages

  162. RF

    7 Pages

  163. KGF

    9 Pages

  164. SVA-FF

    8 Pages

  165. BKA-Ü

    35 Pages

  166. BSK-RPR

    60 Pages

  167. BKP-EN

    40 Pages

  168. BAK-240

    6 Pages

  169. BAK-250

    14 Pages

  170. KF

    4 Pages