video corpo

KGRR
17Pages

{{requestButtons}}

Catalog excerpts

KGRR - 1

Round duct compact grillekgrr Ferdinand Schad KG SleigstraBe 25-27 t i u D-78600 Kolbingen TeFephonie +49 (0) 74 63 - 980 - 0 Fax +49 (0)74 63 - 980 - 200 m1o@schako.de www.schako.de

Open the catalog to page 1
KGRR - 2

01/04 - 2 Construction subject to change. Version: 02.04.2020 No return possible!

Open the catalog to page 2
KGRR - 3

Round duct compact grille type KGRR Description In modern architecture, sheet metal and spiral ducts of air-conditioning systems are often incorporated in the design of the room. Emphasis is often placed deliberately on parts of the supply system. In this visible installation of the ventilation ducts, it is a good idea to integrate the air diffusers into the ducts. The round duct compact grille type KGRR is suitable for installation in supply or return air systems. The air volume throughput can be regulated by using an integrated hit-and-miss damper. The integrated hit-and-miss damper...

Open the catalog to page 3
KGRR - 4

Round duct compact grille type KGRR Correction factor (for scattered air jet) with or without coanda effect The angle of propagation of the air jet and thus the length of throw can be affected by adjusting the vertical air deflection blades. Construction subject to change.

Open the catalog to page 4
KGRR - 5

Available sizes Round duct compact grille type KGRR Dimensions KGRR-08-...-6U-... All combined lengths and nominal widths available! x = available Accessories only available for up to NW500 (see documents for round duct system RR-COMPLETE or accessories for round duct systems). Accessories Detail X Rubber lip seal (-GD1) Construction subject to change.

Open the catalog to page 5
KGRR - 6

Round duct compact grille type KGRR Division of length 1-part: Length 500

Open the catalog to page 6
KGRR - 7

Round duct compact grille type KGRR Technical data Pressure loss and noise level Supply air face velocity 1,5 vstirn (m/s) Hit-and-miss damper position OPEN in % Construction subject to change.

Open the catalog to page 7
KGRR - 8

Round duct compact grille type KGRR Return air face velocity Hit-and-miss damper position OPEN in % 01/04 - 8 Construction subject to change. Version: 02.04.2020 No return possible!

Open the catalog to page 8
KGRR - 9

Round duct compact grille type KGRR FQ in m2 at the hit-and-miss damper Construction subject to change.

Open the catalog to page 9
KGRR - 10

Round duct compact grille type KGRR Maximum end velocity of jet Supply air without coanda effect Supply air with coanda effect 01/04 - 10 Construction subject to change. Version: 02.04.2020 No return possible!

Open the catalog to page 10
KGRR - 11

Round duct compact grille type KGRR Jet path Supply air without coanda effect Heating Cooling Critical throw Supply air with coanda effect 01/04 - 11 Construction subject to change. Version: 02.04.2020 No return possible!

Open the catalog to page 11
KGRR - 12

Round duct compact grille type KGRR Maximum penetration Max. vertical penetration (in heating mode): 01/04 - 12 Construction subject to change. Version: 02.04.2020 No return possible!

Open the catalog to page 12
KGRR - 13

Round duct compact grille type KGRR Temperature and induction ratios Supply air without coanda effect Supply air with coanda effect 01/04 - 13 Construction subject to change. Version: 02.04.2020 No return possible!

Open the catalog to page 13
KGRR - 14

Round duct compact grille type KGRR Legend Vzu (m3/h) [l/s] = Vx (m3/h) [l/s] = Vab (m3/h) [l/s] = vmax (m/s) = Supply air volume total air jet volume at point x Return air volume Maximum end velocity of jet Duct velocity Intake velocity, blower stream velocity, outflow velocity, relative to Astirn Face area horizontal throw Critical throw Vertical throw Maximum penetration in heating mode Critical throw Density Pressure loss A-weighted sound power level (Lwa = lwai + KF) Temperature difference between air supply and room temperature in heating mode (ATOH = tZUH - tRH) Supply air...

Open the catalog to page 14
KGRR - 15

Round duct compact grille type KGRR Order code KGRR 01 All fields must be filled when ordering Round duct compact grille type KGRR I with horizontal, pivoting air deflection blades on the front side and with hit-and-miss damper I nominal width 200 mm | length 1000 mm | grille height 115 mm | blade position straight | sheet steel | painted to RAL colour 9010 (white) | mounting position 6 o'clock | without rubber lip seal | with riveting nut 04 - Length 0500 = Length 500 mm (1-part) 0750 = Length 750 mm (1-part) 1000 = Length 1000 mm (1-part) 1500 = Length 1500 mm (2-part) 1750 = Length 1750...

Open the catalog to page 15
KGRR - 16

Round duct compact grille type KGRR 08 - Paint 0000 = Without paint 9010 = RAL colour 9010 (white, standard) SAND = Painted in the colour sand silver (always for V2A) xxxx = RAL colour can be freely selected (always with 4 digits) 09 - Mounting position 3U =3 o'clock 6U =6 o'clock (standard) 9U = 9 o'clock 0U =12 o'clock 10 - Rubber lip seal GD0 = Without rubber lip seal (standard) GD1 = With rubber lip seal 11 - Riveting nut E0 = Without riveting nut EM = With riveting nut (standard) Construction subject to change.

Open the catalog to page 16
KGRR - 17

Round duct compact grille type KGRR Specification texts Round duct compact grille type KGRR for supply and return air suitable for connection to DIN ducts. With integrated, manually adjustable hit-and-miss damper made of galvanised sheet steel or stainless steel V2A (produced of the same material as the round pipe) for air volume regulation. - With horizontal front side adjustable air deflection blades. Product: SCHAKO type KGRR-08-... - Round duct and blades made of - Sheet steel painted to RAL 9010 (white) (-SB-9010) - Sheet steel painted to a RAL colour of your choice (-SB-xxxx) -...

Open the catalog to page 17

All SCHAKO KG catalogs and technical brochures

  1. AUDIX

    2 Pages

  2. DISA

    4 Pages

  3. UC-OH²

    2 Pages

  4. IGA

    2 Pages

  5. CDD

    2 Pages

  6. FBS

    18 Pages

  7. MINOPAB

    6 Pages

  8. PIL

    23 Pages

  9. MWS / MWK

    23 Pages

  10. ERK-SO

    43 Pages

  11. BKSYS

    18 Pages

  12. MINODSA

    6 Pages

  13. DKA

    6 Pages

  14. LAQ

    11 Pages

  15. VMPR/VMPQ

    29 Pages

  16. BKA-EN

    79 Pages

  17. CPL

    15 Pages

  18. AUDIX®

    25 Pages

  19. VREX

    26 Pages

  20. VQEX

    17 Pages

  21. VPEX

    18 Pages

  22. SVA-FS

    11 Pages

  23. NRWG

    22 Pages

  24. COMBIDSC

    26 Pages

  25. DSCXL

    17 Pages

  26. DSCU

    18 Pages

  27. DSCPL

    16 Pages

  28. DSCP

    15 Pages

  29. DSC

    37 Pages

  30. DO

    10 Pages

  31. VRAQ

    46 Pages

  32. UEKU

    6 Pages

  33. UEK

    6 Pages

  34. SS-K

    6 Pages

  35. DQJP

    9 Pages

  36. VOLKOM

    6 Pages

  37. DQJ

    38 Pages

  38. ALPETY

    16 Pages

  39. CTT

    23 Pages

  40. STV

    8 Pages

  41. KWB

    19 Pages

  42. GREENKIT

    20 Pages

  43. FKU

    31 Pages

  44. FKF

    29 Pages

  45. SGA

    5 Pages

  46. DBB

    27 Pages

  47. TVO

    8 Pages

  48. AL

    23 Pages

  49. SVA-FF

    15 Pages

  50. RF

    7 Pages

  51. NBS

    34 Pages

  52. MKAR_MKAQ

    13 Pages

  53. KGF

    11 Pages

  54. KF

    4 Pages

  55. JK

    16 Pages

  56. HK

    16 Pages

  57. FLARE

    13 Pages

  58. FLAQ

    11 Pages

  59. FKW

    28 Pages

  60. FG

    14 Pages

  61. ERK-MB

    38 Pages

  62. DISA-H

    34 Pages

  63. DISA-B

    32 Pages

  64. DISA-601

    41 Pages

  65. DISA-360

    32 Pages

  66. DISA-300

    51 Pages

  67. CNVA

    32 Pages

  68. CNV

    29 Pages

  69. BSK-RPR

    60 Pages

  70. BKP-EN

    40 Pages

  71. BKA-UE

    35 Pages

  72. BAK-250

    17 Pages

  73. BAK-240

    16 Pages

  74. Aquaris-Silent

    38 Pages

  75. Aquaris_KWB

    20 Pages

  76. DISA-W

    43 Pages

  77. PILB/PILBR

    33 Pages

  78. DAV

    19 Pages

  79. 4DE

    18 Pages

  80. 4DF

    13 Pages

  81. DQC

    16 Pages

  82. DQDL

    16 Pages

  83. IDA

    21 Pages

  84. IKA

    23 Pages

  85. ZMD

    17 Pages

  86. DQF

    15 Pages

  87. DQJF

    12 Pages

  88. DQJA/DQJR

    10 Pages

  89. DQJSL

    17 Pages

  90. DQJSLC

    17 Pages

  91. DHV

    18 Pages

  92. DSARR

    7 Pages

  93. QA

    30 Pages

  94. PUSH

    23 Pages

  95. WQA

    12 Pages

  96. DSX-XXL

    23 Pages

  97. AUDIX®-ÜSG

    13 Pages

  98. SIA

    7 Pages

  99. SAR/SAQ/SARP

    13 Pages

  100. WDA

    32 Pages

  101. DBBRR

    11 Pages

  102. WGARR

    7 Pages

  103. WGA

    29 Pages

  104. DKAPPs

    6 Pages

  105. EBE/EBP

    52 Pages

  106. VRAPPs

    20 Pages

  107. VRAR

    52 Pages

  108. MAK

    15 Pages

  109. DISA-Family

    4 Pages

  110. RMS

    11 Pages

  111. EasyBus

    24 Pages

  112. TSR

    5 Pages

  113. RS-F

    7 Pages

  114. RS

    15 Pages

  115. VLV

    31 Pages

  116. VARS

    26 Pages

  117. VAQS

    19 Pages

  118. VAS

    26 Pages

  119. PIANO

    27 Pages

  120. MBM

    10 Pages

  121. MBE/MBP

    27 Pages

  122. DKG

    6 Pages

  123. ALAS-P

    5 Pages

  124. ALAS-F 125

    6 Pages

  125. ALAS

    10 Pages

  126. ALA-SO

    4 Pages

  127. ALA-R

    4 Pages

  128. ALA

    4 Pages

  129. LL

    7 Pages

  130. RR-Complete

    41 Pages

  131. DBBR

    6 Pages

  132. PA

    32 Pages

  133. LK

    12 Pages

  134. IB-R

    15 Pages

  135. IB-Q

    21 Pages

  136. KG

    19 Pages

  137. BSG

    19 Pages

  138. DSX-XXL-W

    25 Pages

  139. AUDIX®-AW

    20 Pages

  140. DSX

    25 Pages

  141. MINODSX

    6 Pages

  142. MINODSA

    6 Pages

  143. DSA

    15 Pages

  144. COMBIPIL

    11 Pages

  145. COMBIDQJ

    11 Pages

  146. MINOPAB

    6 Pages

  147. BDA

    11 Pages

  148. SPB

    10 Pages

  149. DISA-H

    34 Pages

  150. DISA-601

    41 Pages

  151. DISA-360

    32 Pages

  152. DISA-300

    51 Pages

  153. DISA-B

    32 Pages

  154. AQUARIS SILENT

    38 Pages

  155. NBS

    24 Pages

  156. CNV

    29 Pages

  157. CNVA

    32 Pages

  158. JK-LP/JK-LU

    15 Pages

  159. HKP / HKU

    16 Pages

  160. FKW

    16 Pages

  161. FLARE

    13 Pages

  162. RF

    7 Pages

  163. KGF

    9 Pages

  164. SVA-FF

    8 Pages

  165. BKA-Ü

    35 Pages

  166. BSK-RPR

    60 Pages

  167. BKP-EN

    40 Pages

  168. BAK-240

    6 Pages

  169. BAK-250

    14 Pages

  170. KF

    4 Pages