DISA-601 - 2

11/28 - 2 Construction subject to change. Version: 20.10.2015 No return possible!

Open the catalog to page 2
DISA-601 - 3

Ceiling induction diffuser DISA-601 Description Ceiling induction diffusers combine the flow characteristics of air diffusers with the energetic advantages of load discharge via water-based heat exchangers, allowing them to remove high thermal loads from the room while keeping the hygienically required air exchange low. The construction of the ceiling induction diffuser DISA-601 is very maintenance- and mountingfriendly and is also suitable for low false ceiling heights, due to its small height. Its 4 different nozzle configurations B, C, D, E and lengths of up to 3.0 metres allow the...

Open the catalog to page 3
DISA-601 - 4

Ceiling induction diffuser DISA-601 Model DISA-601-H DISA-601-HT DISA-601-BO DISA-...-LE DISA-...-LB DISA-...-SR DISA-...-SQ DISA-...-RE DISA-...-OB DISA-...-PA DISA-...-B DISA-...-C DISA-...-D DISA-...-E DISA-...-592 DISA-...-597 DISA-...-617 DISA-...-622 DISA-...-FM DISA-...-900 DISA-...-1200 DISA-...-1500 DISA-...-1800 DISA-...-2100 DISA-...-2400 DISA-...-2700 DISA-...-3000 DISA-...-2E DISA-...-EL DISA-...-ER DISA-...-OE DISA-...-A DISA-...-BA Description of the equipment Construction Housing - Galvanised sheet steel with 1 or 2 primary air connection pieces 098, 0123 (standard) and 0148...

Open the catalog to page 4
DISA-601 - 5

Ceiling induction diffuser DISA-601 Models and dimensions Dimensions and weights with perforated sheet grille (-SR/-SQ/-RE/-OB) LG* (mm) = total length of the device with and without end pieces B (mm) = 592 / 597 / 617 / 622 / 900(-FM) øD (mm) = diameter of the connection pieces (98, 123 and 148) with louvre grid (-PA) Arrangement of the connection pieces (-AS) and water connection (-WS) Horizontal connection (-H) Vertical connection (-V) Number/position of the connection pieces - with horizontal connection (-H) - with 1 central connection piece (-AS1) or (-AS4) - with 2 connection pieces...

Open the catalog to page 5
DISA-601 - 6

Construction subject to change.

Open the catalog to page 6
DISA-601 - 7

Fixing brackets Accessories Band design (-BA) Rubber lip seal (-GD) At the connecting piece for better tightness. Volumetric flow measuring tube (-MR) - Individually adjustable air deflection blades (-LE) - Blockwise adjustable air deflection blades (-LB) With blockwise adjustable blades, 5 blades can be adjusted simultaneously. A The adjusting angle of the air deflection blades must /*\ not be more than ± 45°, in order to guarantee its function. A At an adjusting angle of the air deflection blades out-/ . % side the straight air throw of up to 45°, the cooling capacity of the heat...

Open the catalog to page 7
DISA-601 - 8

Ceiling induction diffuser DISA-601 Figures DISA-601 with end piece (-2E, standard) View from below DISA-601 without end piece (-OE) System solution SCHAKO offers system solutions that can be integrated perfectly into the room architecture. Example of a system solution with lighting and sprinkler DISA-601 band design without end pieces mounted in-between Construction subject to change.

Open the catalog to page 8
DISA-601 - 9

Ceiling induction diffuser DISA-601Technical data Performance data DISA-601-H -...-B -Cooling- NL (mm) Construction subject to change.

Open the catalog to page 9
DISA-601 - 10

Ceiling induction diffuser DISA-601DISA-601-HT-...-B -Cooling- NL (mm) Construction subject to change.

Open the catalog to page 10
DISA-601 - 11

Ceiling induction diffuser DISA-601DISA-601-H -...-C -Cooling- NL (mm) Construction subject to change.

Open the catalog to page 11
DISA-601 - 12

Ceiling induction diffuser DISA-601DISA-601-HT-...-C -Cooling- NL (mm) Construction subject to change.

Open the catalog to page 12
DISA-601 - 13

Ceiling induction diffuser DISA-601DISA-601-H -...-D -Cooling- NL (mm)

Open the catalog to page 13
DISA-601 - 14

Ceiling induction diffuser DISA-601DISA-601-HT-...-D -Cooling- NL (mm)

Open the catalog to page 14
DISA-601 - 15

Ceiling induction diffuser DISA-601DISA-601-H -...-E -Cooling- NL (mm)

Open the catalog to page 15
DISA-601 - 16

Ceiling induction diffuser DISA-601DISA-601-HT-...-E -Cooling- NL (mm) Construction subject to change.

Open the catalog to page 16
DISA-601 - 17

Ceiling induction diffuser DISA-601DISA-601-H -...-B -Heating- NL (mm)

Open the catalog to page 17
DISA-601 - 18

Ceiling induction diffuser DISA-601DISA-601-HT-...-B -Heating- NL (mm) Construction subject to change.

Open the catalog to page 18
DISA-601 - 19

Ceiling induction diffuser DISA-601DISA-601-H -...-C -Heating- NL (mm)

Open the catalog to page 19
DISA-601 - 20

Ceiling induction diffuser DISA-601DISA-601-HT-...-C -Heating- NL (mm) Construction subject to change.

Open the catalog to page 20
DISA-601 - 21

Ceiling induction diffuser DISA-601DISA-601-H -...-D -Heating- NL (mm) Construction subject to change.

Open the catalog to page 21
DISA-601 - 22

Ceiling induction diffuser DISA-601DISA-601-HT-...-D -Heating- NL (mm) Construction subject to change.

Open the catalog to page 22
DISA-601 - 23

Ceiling induction diffuser DISA-601DISA-601-H -...-E -Heating- NL (mm)

Open the catalog to page 23
DISA-601 - 24

Ceiling induction diffuser DISA-601DISA-601-HT-...-E -Heating- NL (mm)

Open the catalog to page 24
DISA-601 - 25

Ceiling induction diffuser DISA-601 Sound level Sound pressure level (room damping -8 dB) L (mm)

Open the catalog to page 25
DISA-601 - 26

Ceiling induction diffuser DISA-601 Flow data DISA-601-...-B-... Maximum end velocity of jet (isotherm) with coanda effect Critical throw Correction factors for the critical throw Water Amount of water Correction factor ΔtRWV (K) [l/h] x critical 6 8 10 6 8 10 vmittel = vmax x 0.8 Length correction factors for air volumes VZU x KF NL 11/28 - 26 Construction subject to change. Version: 20.10.2015 No return possible!

Open the catalog to page 26
DISA-601 - 27

Ceiling induction diffuser DISA-601 Maximum end velocity of jet (isotherm) at floor level Temperature ratio / induction ratio secondary slot - primary air only Length correction factors for air volumes VZU x KF NL 11/28 - 27 Construction subject to change. Version: 20.10.2015 No return possible!

Open the catalog to page 27
DISA-601 - 28

Ceiling induction diffuser DISA-601 DISA-601-...-C-... Maximum end velocity of jet (isotherm) with coanda effect vmittel = vmax x 0.8 Length correction factors for air volumes VZU x KF NL Correction factors for the critical throw Water Amount of water Correction factor ΔtRWV (K) [l/h] x critical 6 11/28 - 28 Construction subject to change. Version: 20.10.2015 No return possible!

Open the catalog to page 28
DISA-601 - 29

Ceiling induction diffuser DISA-601 Maximum end velocity of jet (isotherm) at floor level Temperature ratio / induction ratio secondary slot - primary air only Length correction factors for air volumes VZU x KF NL 11/28 - 29 Construction subject to change. Version: 20.10.2015 No return possible!

Open the catalog to page 29
DISA-601 - 30

DISA-601-...-D-...Critical throw Maximum end velocity of jet (isotherm) with coanda effect vmittel _ vmax x 11/28 - 30 Version: 20.10.2015 Construction subject to change. No return possible!

Open the catalog to page 30

All SCHAKO KG catalogs and technical brochures

  1. AUDIX

    2 Pages

  2. DISA

    4 Pages

  3. UC-OH²

    2 Pages

  4. IGA

    2 Pages

  5. CDD

    2 Pages

  6. FBS

    18 Pages

  7. MINOPAB

    6 Pages

  8. PIL

    23 Pages

  9. MWS / MWK

    23 Pages

  10. ERK-SO

    43 Pages

  11. BKSYS

    18 Pages

  12. MINODSA

    6 Pages

  13. DKA

    6 Pages

  14. LAQ

    11 Pages

  15. VMPR/VMPQ

    29 Pages

  16. BKA-EN

    79 Pages

  17. CPL

    15 Pages

  18. AUDIX®

    25 Pages

  19. VREX

    26 Pages

  20. VQEX

    17 Pages

  21. VPEX

    18 Pages

  22. SVA-FS

    11 Pages

  23. NRWG

    22 Pages

  24. COMBIDSC

    26 Pages

  25. DSCXL

    17 Pages

  26. DSCU

    18 Pages

  27. DSCPL

    16 Pages

  28. DSCP

    15 Pages

  29. DSC

    37 Pages

  30. DO

    10 Pages

  31. VRAQ

    46 Pages

  32. UEKU

    6 Pages

  33. UEK

    6 Pages

  34. SS-K

    6 Pages

  35. DQJP

    9 Pages

  36. VOLKOM

    6 Pages

  37. DQJ

    38 Pages

  38. ALPETY

    16 Pages

  39. CTT

    23 Pages

  40. STV

    8 Pages

  41. KWB

    19 Pages

  42. GREENKIT

    20 Pages

  43. FKU

    31 Pages

  44. FKF

    29 Pages

  45. SGA

    5 Pages

  46. DBB

    27 Pages

  47. TVO

    8 Pages

  48. AL

    23 Pages

  49. SVA-FF

    15 Pages

  50. RF

    7 Pages

  51. NBS

    34 Pages

  52. MKAR_MKAQ

    13 Pages

  53. KGF

    11 Pages

  54. KF

    4 Pages

  55. JK

    16 Pages

  56. HK

    16 Pages

  57. FLARE

    13 Pages

  58. FLAQ

    11 Pages

  59. FKW

    28 Pages

  60. FG

    14 Pages

  61. ERK-MB

    38 Pages

  62. DISA-H

    34 Pages

  63. DISA-B

    32 Pages

  64. DISA-360

    32 Pages

  65. DISA-300

    51 Pages

  66. CNVA

    32 Pages

  67. CNV

    29 Pages

  68. BSK-RPR

    60 Pages

  69. BKP-EN

    40 Pages

  70. BKA-UE

    35 Pages

  71. BAK-250

    17 Pages

  72. BAK-240

    16 Pages

  73. Aquaris-Silent

    38 Pages

  74. Aquaris_KWB

    20 Pages

  75. DISA-W

    43 Pages

  76. PILB/PILBR

    33 Pages

  77. DAV

    19 Pages

  78. 4DE

    18 Pages

  79. 4DF

    13 Pages

  80. DQC

    16 Pages

  81. DQDL

    16 Pages

  82. IDA

    21 Pages

  83. IKA

    23 Pages

  84. ZMD

    17 Pages

  85. DQF

    15 Pages

  86. DQJF

    12 Pages

  87. DQJA/DQJR

    10 Pages

  88. DQJSL

    17 Pages

  89. DQJSLC

    17 Pages

  90. DHV

    18 Pages

  91. DSARR

    7 Pages

  92. QA

    30 Pages

  93. PUSH

    23 Pages

  94. WQA

    12 Pages

  95. DSX-XXL

    23 Pages

  96. AUDIX®-ÜSG

    13 Pages

  97. SIA

    7 Pages

  98. SAR/SAQ/SARP

    13 Pages

  99. WDA

    32 Pages

  100. KGRR

    17 Pages

  101. DBBRR

    11 Pages

  102. WGARR

    7 Pages

  103. WGA

    29 Pages

  104. DKAPPs

    6 Pages

  105. EBE/EBP

    52 Pages

  106. VRAPPs

    20 Pages

  107. VRAR

    52 Pages

  108. MAK

    15 Pages

  109. DISA-Family

    4 Pages

  110. RMS

    11 Pages

  111. EasyBus

    24 Pages

  112. TSR

    5 Pages

  113. RS-F

    7 Pages

  114. RS

    15 Pages

  115. VLV

    31 Pages

  116. VARS

    26 Pages

  117. VAQS

    19 Pages

  118. VAS

    26 Pages

  119. PIANO

    27 Pages

  120. MBM

    10 Pages

  121. MBE/MBP

    27 Pages

  122. DKG

    6 Pages

  123. ALAS-P

    5 Pages

  124. ALAS-F 125

    6 Pages

  125. ALAS

    10 Pages

  126. ALA-SO

    4 Pages

  127. ALA-R

    4 Pages

  128. ALA

    4 Pages

  129. LL

    7 Pages

  130. RR-Complete

    41 Pages

  131. DBBR

    6 Pages

  132. PA

    32 Pages

  133. LK

    12 Pages

  134. IB-R

    15 Pages

  135. IB-Q

    21 Pages

  136. KG

    19 Pages

  137. BSG

    19 Pages

  138. DSX-XXL-W

    25 Pages

  139. AUDIX®-AW

    20 Pages

  140. DSX

    25 Pages

  141. MINODSX

    6 Pages

  142. MINODSA

    6 Pages

  143. DSA

    15 Pages

  144. COMBIPIL

    11 Pages

  145. COMBIDQJ

    11 Pages

  146. MINOPAB

    6 Pages

  147. BDA

    11 Pages

  148. SPB

    10 Pages

  149. DISA-H

    34 Pages

  150. DISA-601

    41 Pages

  151. DISA-360

    32 Pages

  152. DISA-300

    51 Pages

  153. DISA-B

    32 Pages

  154. AQUARIS SILENT

    38 Pages

  155. NBS

    24 Pages

  156. CNV

    29 Pages

  157. CNVA

    32 Pages

  158. JK-LP/JK-LU

    15 Pages

  159. HKP / HKU

    16 Pages

  160. FKW

    16 Pages

  161. FLARE

    13 Pages

  162. RF

    7 Pages

  163. KGF

    9 Pages

  164. SVA-FF

    8 Pages

  165. BKA-Ü

    35 Pages

  166. BSK-RPR

    60 Pages

  167. BKP-EN

    40 Pages

  168. BAK-240

    6 Pages

  169. BAK-250

    14 Pages

  170. KF

    4 Pages