video corpo

CPL
15Pages

{{requestButtons}}

Catalog excerpts

CPL - 1

Technical documentation SCHAKO | Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen

Open the catalog to page 1
CPL - 2

Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Function and use I Processing FUNCTION AND USE CPL-E-... CPL-...-Z-... CPL-...-A-... CPL-...-3-... CPL-...-5-... CPL-...-300-... CPL-...-312-... CPL-...-600-... CPL-...-625-... The ceiling air diffuser type CPL for supply and return air is suitable for use in rooms from 2.6 to 4 m high. With the supply air model, a special intake funnel behind an existing on-site perforated ceiling panel creates a horizontal air jet below the ceiling for cooling mode and isothermal ventilation mode. A high induction is achieved while the velocity and...

Open the catalog to page 2
CPL - 3

Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Dimensions I CPL-E-... (ceiling air diffuser mounted to the ceiling panel) FQ = 16.2 % (RG-L15; 02.5 mm) FQ = 25.0 % (RV-L6; 02.1 mm) DPB = ceiling panel width DPL = ceiling panel length - = not possible Construction subject to change No return possible Version: 2020-03-24 | Page 3

Open the catalog to page 3
CPL - 4

TECHNICAL DOCUMENTATION Dimensions of accessories I DIMENSIONS OF ACCESSORIES Plenum box (-SK) SK-...-S1 (standard), lateral spigot external Rubber seal (made of EPDM) CPL CPL and SK are not permanently connected to one another. SK-...-S0, spigot from above external Air diffuser plate (for supply air model only) With the VME1 model, the projection dimension is approx. 102 mm. KHS= standard height of plenum box Special height of plenum box øD + 137 mm, but at least 235 mm. Spigot position - 1 spigot from above (-S0) 1 lateral spigot (-S1) (standard) 2 lateral spigots, offset by 90° (-S2) 2...

Open the catalog to page 4
CPL - 5

Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Dimensions of accessories I Connection to flexible duct Lateral spigot spigot from above Connection elbow (-K030/-K045/-K090) according to DIN EN 1506, consisting of a BGE bend made of galvanised sheet steel. Only possible without plenum box! Bend model: - as a pressed BGE bend with an angle degree: a = 30° (-K030) a = 45° (-K045) a = 90° (-K090) Volumetric flow meter (-VME1), for SK Bend supplied lose, inserted and screwed on site, screws provided on site Internal or external insulation (-Ii / -Ia), for SK Construction subject to change No...

Open the catalog to page 5
CPL - 6

TECHNICAL DOCUMENTATION Technical data I TECHNICAL DATA Pressure loss and noise level for supply air / with plenum box and damper Damper position (DS): 0% = CLOSED 100% = OPEN Z = supply air with on-site ceiling panel FQ 16.2% (RG-L15; ø2.5) CPL-E-Z-3-…-SK-...-DK1 with on-site ceiling panel FQ 25% (RV-L6; ø2.1) CPL-E-Z-3-…-SK-...-DK1 Construction subject to change No return possible

Open the catalog to page 6
CPL - 7

TECHNICAL DOCUMENTATION Technical data I for return air / with plenum box and damper Damper position (DS): 0% = CLOSED 100% = OPEN A = return air with on-site ceiling panel FQ 16.2% (RG-L15; ø2.5) CPL-E-A-3-…-SK-...-DK1 with on-site ceiling panel FQ 25% (RV-L6; ø2.1) CPL-E-A-3-…-SK-...-DK1 Construction subject to change No return possible

Open the catalog to page 7
CPL - 8

TECHNICAL DOCUMENTATION Technical data I for return air / with connection elbow with on-site ceiling panel for supply air / with connection elbow with on-site ceiling panel on-site ceiling panel: FQ 25% = RV-L6; ø2.1 FQ 16.2% = RG-L15; ø2.5 Construction subject to change No return possible

Open the catalog to page 8
CPL - 9

TECHNICAL DOCUMENTATION Technical data I with on-site ceiling panel FQ 16.2% (RG-L15; ø2.5) with on-site ceiling panel FQ 25% (RV-L6; ø2.1) Construction subject to change No return possible

Open the catalog to page 9
CPL - 10

TECHNICAL DOCUMENTATION Technical data I Critical throw with on-site ceiling panel FQ 16.2% (RG-L15; ø2.5) with on-site ceiling panel FQ 25% (RV-L6; ø2.1) Construction subject to change No return possible

Open the catalog to page 10
CPL - 11

TECHNICAL DOCUMENTATION Technical data I Temperature and induction ratios with on-site ceiling panel FQ 16.2% (RG-L15; ø2.5) with on-site ceiling panel FQ 25% (RV-L6; ø2.1) Construction subject to change No return possible

Open the catalog to page 11
CPL - 12

Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Minimum air volumes I Legend Vzu (m3/h) [l/s] Vab (m3/h) [l/s] Vmin (m3/h) [l/s] Lwa [dB(A)] Apt (Pa) P (kg/m3) DS (%) FQ (%) Vmax (m/s) x (m) y (m) x+y (m) Vmittel (m/s) Xkr (m) ATo (K) Ceiling air diffuser type CPL-Z (supply air) with on-site perforated ceiling panel - FQ = 16.2% (RG-L15; 02.5) Supply air volume Return air volume Minimum volume A-weighted sound power level Total pressure loss Density Damper position Free cross-section Maximum end velocity of jet horizontal throw vertical throw horizontal + vertical throw Average end...

Open the catalog to page 12
CPL - 13

Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Order code CPL I Sample CPL-E-Z-5-600-AL-K000 Ceiling air diffuser type CPL | only ceiling air diffuser | supply air | NW 500| ceiling panel width 600 mm | aluminium painted to the RAL colour 9005 (black) | without connection elbow ORDER DETAILS 01 - Type CPL = ceiling air diffuser CPL 02 - Model E = only ceiling air diffuser 03 - Air throw Z = supply air (standard), with central disc 04 - Nominal size of intake funnel 3 = NW 300 05 - Ceiling panel width 300 = Ceiling panel width 300 mm (not possible for NW 500) 312 = Ceiling panel width 312...

Open the catalog to page 13
CPL - 14

Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Order code SK I Sample SK-R-71-Z-500-OM-SV-DK1-GD1-VME0-ROB0-I0-KHS-SDS-S1 Plenum box, square design | for round air diffusers with round diffuser support | air diffuser CPL | supply air | NW 500 | without mounting | galvanised sheet steel | with damper | with rubber lip seal | without volumetric flow meter | without ROB version | without box insulation | standard height of plenum box | standard spigot diameter | 1 lateral spigot ORDER DETAILS 01 - Type SK = plenum box, square design 02 - Model R = for round air diffusers with round diffuser...

Open the catalog to page 14
CPL - 15

Ceiling air diffuser CPL TECHNICAL DOCUMENTATION Specification text I Ceiling air diffuser type CPL for supply and return air for use in rooms from 2.6 to 4 m high. Highly inductive air diffuser, air velocity and temperature difference of the supply air jet are effectively reduced. The stable air jet and high induction mean that the CPL ceiling air diffuser can be used in cooling mode up to ATO < -10 K. Consists of an adaptor plate and intake funnel made of aluminium painted to the RAL colour RAL 9005 (black). With supply air model additionally with central disc made of galvanised sheet...

Open the catalog to page 15

All SCHAKO KG catalogs and technical brochures

  1. AUDIX

    2 Pages

  2. DISA

    4 Pages

  3. UC-OH²

    2 Pages

  4. IGA

    2 Pages

  5. CDD

    2 Pages

  6. FBS

    18 Pages

  7. MINOPAB

    6 Pages

  8. PIL

    23 Pages

  9. MWS / MWK

    23 Pages

  10. ERK-SO

    43 Pages

  11. BKSYS

    18 Pages

  12. MINODSA

    6 Pages

  13. DKA

    6 Pages

  14. LAQ

    11 Pages

  15. VMPR/VMPQ

    29 Pages

  16. BKA-EN

    79 Pages

  17. AUDIX®

    25 Pages

  18. VREX

    26 Pages

  19. VQEX

    17 Pages

  20. VPEX

    18 Pages

  21. SVA-FS

    11 Pages

  22. NRWG

    22 Pages

  23. COMBIDSC

    26 Pages

  24. DSCXL

    17 Pages

  25. DSCU

    18 Pages

  26. DSCPL

    16 Pages

  27. DSCP

    15 Pages

  28. DSC

    37 Pages

  29. DO

    10 Pages

  30. VRAQ

    46 Pages

  31. UEKU

    6 Pages

  32. UEK

    6 Pages

  33. SS-K

    6 Pages

  34. DQJP

    9 Pages

  35. VOLKOM

    6 Pages

  36. DQJ

    38 Pages

  37. ALPETY

    16 Pages

  38. CTT

    23 Pages

  39. STV

    8 Pages

  40. KWB

    19 Pages

  41. GREENKIT

    20 Pages

  42. FKU

    31 Pages

  43. FKF

    29 Pages

  44. SGA

    5 Pages

  45. DBB

    27 Pages

  46. TVO

    8 Pages

  47. AL

    23 Pages

  48. SVA-FF

    15 Pages

  49. RF

    7 Pages

  50. NBS

    34 Pages

  51. MKAR_MKAQ

    13 Pages

  52. KGF

    11 Pages

  53. KF

    4 Pages

  54. JK

    16 Pages

  55. HK

    16 Pages

  56. FLARE

    13 Pages

  57. FLAQ

    11 Pages

  58. FKW

    28 Pages

  59. FG

    14 Pages

  60. ERK-MB

    38 Pages

  61. DISA-H

    34 Pages

  62. DISA-B

    32 Pages

  63. DISA-601

    41 Pages

  64. DISA-360

    32 Pages

  65. DISA-300

    51 Pages

  66. CNVA

    32 Pages

  67. CNV

    29 Pages

  68. BSK-RPR

    60 Pages

  69. BKP-EN

    40 Pages

  70. BKA-UE

    35 Pages

  71. BAK-250

    17 Pages

  72. BAK-240

    16 Pages

  73. Aquaris-Silent

    38 Pages

  74. Aquaris_KWB

    20 Pages

  75. DISA-W

    43 Pages

  76. PILB/PILBR

    33 Pages

  77. DAV

    19 Pages

  78. 4DE

    18 Pages

  79. 4DF

    13 Pages

  80. DQC

    16 Pages

  81. DQDL

    16 Pages

  82. IDA

    21 Pages

  83. IKA

    23 Pages

  84. ZMD

    17 Pages

  85. DQF

    15 Pages

  86. DQJF

    12 Pages

  87. DQJA/DQJR

    10 Pages

  88. DQJSL

    17 Pages

  89. DQJSLC

    17 Pages

  90. DHV

    18 Pages

  91. DSARR

    7 Pages

  92. QA

    30 Pages

  93. PUSH

    23 Pages

  94. WQA

    12 Pages

  95. DSX-XXL

    23 Pages

  96. AUDIX®-ÜSG

    13 Pages

  97. SIA

    7 Pages

  98. SAR/SAQ/SARP

    13 Pages

  99. WDA

    32 Pages

  100. KGRR

    17 Pages

  101. DBBRR

    11 Pages

  102. WGARR

    7 Pages

  103. WGA

    29 Pages

  104. DKAPPs

    6 Pages

  105. EBE/EBP

    52 Pages

  106. VRAPPs

    20 Pages

  107. VRAR

    52 Pages

  108. MAK

    15 Pages

  109. DISA-Family

    4 Pages

  110. RMS

    11 Pages

  111. EasyBus

    24 Pages

  112. TSR

    5 Pages

  113. RS-F

    7 Pages

  114. RS

    15 Pages

  115. VLV

    31 Pages

  116. VARS

    26 Pages

  117. VAQS

    19 Pages

  118. VAS

    26 Pages

  119. PIANO

    27 Pages

  120. MBM

    10 Pages

  121. MBE/MBP

    27 Pages

  122. DKG

    6 Pages

  123. ALAS-P

    5 Pages

  124. ALAS-F 125

    6 Pages

  125. ALAS

    10 Pages

  126. ALA-SO

    4 Pages

  127. ALA-R

    4 Pages

  128. ALA

    4 Pages

  129. LL

    7 Pages

  130. RR-Complete

    41 Pages

  131. DBBR

    6 Pages

  132. PA

    32 Pages

  133. LK

    12 Pages

  134. IB-R

    15 Pages

  135. IB-Q

    21 Pages

  136. KG

    19 Pages

  137. BSG

    19 Pages

  138. DSX-XXL-W

    25 Pages

  139. AUDIX®-AW

    20 Pages

  140. DSX

    25 Pages

  141. MINODSX

    6 Pages

  142. MINODSA

    6 Pages

  143. DSA

    15 Pages

  144. COMBIPIL

    11 Pages

  145. COMBIDQJ

    11 Pages

  146. MINOPAB

    6 Pages

  147. BDA

    11 Pages

  148. SPB

    10 Pages

  149. DISA-H

    34 Pages

  150. DISA-601

    41 Pages

  151. DISA-360

    32 Pages

  152. DISA-300

    51 Pages

  153. DISA-B

    32 Pages

  154. AQUARIS SILENT

    38 Pages

  155. NBS

    24 Pages

  156. CNV

    29 Pages

  157. CNVA

    32 Pages

  158. JK-LP/JK-LU

    15 Pages

  159. HKP / HKU

    16 Pages

  160. FKW

    16 Pages

  161. FLARE

    13 Pages

  162. RF

    7 Pages

  163. KGF

    9 Pages

  164. SVA-FF

    8 Pages

  165. BKA-Ü

    35 Pages

  166. BSK-RPR

    60 Pages

  167. BKP-EN

    40 Pages

  168. BAK-240

    6 Pages

  169. BAK-250

    14 Pages

  170. KF

    4 Pages