1. Catalogs
  2. Scan A/S
  3. SCAN 67 1300

SCAN 67 1300
1 /36Pages

SCAN 67 1300

SCAN 67 1300
1 /36Pages

Catalog excerpts

SCAN 67 1300-1

EU - ASSEMBLY AND INSTRUCTIONS MANUAL ASSEMBLY AND INSTRUCTIONS MANUAL SCAN 67

 Open the catalog to page 1
SCAN 67 1300-2

CONGRATULATIONS ON YOUR NEW SCAN WOOD-BURNING STOVE You have purchased a product by one of Europe’s leading manufacturers of wood-burning stoves, and we are sure that you will have years of pleasure from your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions. Read through this Assembly and Instruction Manual carefully before you start to assemble your stove.

 Open the catalog to page 2
SCAN 67 1300-3

Technical data and dimensions 4 Dimension sketch and minimum distances 6 5 Product registration number 8 ■ ASSEMBLY Tools needed for mounting of the stove 9 Closed combustion system 10 Existing chimney and pre-fabricated element chimney 10 Connection between stove and steel chimney 10 Balanced draft chimney compatability 11 Removal of transport protection 14 Setting of electronic air control 15 Charging of electronic air control 15 Height adjustment of stove 16 Fitting the flue connection piece 18 CB-technology (Clean Burn) 23 Baffle plates 23 Electronic air control 23 Ash container 23 Warning...

 Open the catalog to page 3
SCAN 67 1300-4

TECHNICAL DATA INSTALLATION ¬ The house owner is responsible for ensuring that installation and assembly are in accordance with national and local building regulations as well as the information provided in this Assembly and Instruction Manual ¬ When you install any kind of fireplace or stove, you must inform the local building and housing authorities. In addition you are obliged to have the installation inspected and approved by a local chimney sweep prior to commissioning ¬ To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter. Your...

 Open the catalog to page 4
SCAN 67 1300-6

Floor plate TG.NR: MATERIALE: DATO: 12-01-2022 DK-5492 Vissenbjerg© Folder\Designs\Scan 67\90067003.idw STI: C:\Working DIMENSION: Krog Iversen & Co A/S Radiation zone X / Y according to national laws and regulations All distances are in mm. All distances are minimum distances * Connection of fresh-air intake Ø 100 mm ** Min. distance to furniture/flammable material *** Height to the beginning of flue connecting piece at top outlet Flammable material DIMENSION SKETCH AND MINIMUM D

 Open the catalog to page 6
SCAN 67 1300-7

Fire wall, e.g. 50 mm Jøtul Firewall, 110 mm brick or other material with corresponding fireproof and insulating abilities Flammable material TG.NR: SIGN: Opstillingstegning (afstand til brændbart materiale) All distances are in mm. All distances are minimum distances * Half-insulated chimney / shielded flue pipe (The requirements to the chimney and the flue pipe in terms of safety distances must be met) Opstillingstegning (afstand til brændbart materiale) Minimum distance to flammable wall protected by a fire wall i en en er 13 rs iss at : O ve(afstand V Opstillingstegning til brændbart materiale)...

 Open the catalog to page 7
SCAN 67 1300-8

TYPE PLATE All Scan wood-burning stoves are fitted with a type plate that specifies the approval standards and the distance to flammable materials. The type plate is located at the rear of the stove. Typeplate Type plate Product registration number Product registration number PRODUCT REGISTRATION NUMBER All Scan wood-burning stoves are provided with a product registration number. Please make a note of this number at the rear page of this manual; you will always need to quote it when contacting your dealer or Scan A/S. AREAL: 49245985 DIMENSION: The product registration number is located at the...

 Open the catalog to page 8
SCAN 67 1300-9

NOTE!Before installing the product, you must check whether the stove can be used with a balanced chimney. To do this, see page 11.TOOLS NEEDED FOR MOUNTING OF THE STOVE ■ Spirit level ■ Combo wrench 8 mm ■ Cutting nippers ■ 3 alien keys (2,5 mm, 4 mm & 5 mm) LOOSE PARTS In the stoves combustion chamber you will find the following loose parts: ■ Glove ■ Connecting piece 148 cm for outside flue pipe ■ Seal for the connecting piece ■ Dekor plate for top plate ■ Ring for dekor plate ■ 2 pcs. screws M5x10 mm for fastening the ring ■ USB-C charger cable for Zensoric control ■ Eco energy label ADDITIONAL...

 Open the catalog to page 9
SCAN 67 1300-10

CLOSED COMBUSTION SYSTEM You should use the closed combustion system for the wood-burning stove if you live in a newly-built, airtight home. External combustion air is connected through a ventilation pipe via the wall or floor. We recommend mounting a valve in the ventilation pipe in order to avoid condensate in the stove and the pipe system, when the stove is not in use. It can also be an advantage to insulate the ventilation pipe. Minimum Ø 100 mm ventilation pipe, maximum length: 6 metres with a maximum of one bend. We recommend smooth steel pipes. NOTE: if the stove has a fresh air connexion...

 Open the catalog to page 10
SCAN 67 1300-11

REQUIREMENTS FOR CHIMNEY The chimney must at least have a T400 designation, with G for the soot fire test. We recommend a chimney with a minimum internal diameter of 148 mm and a length of min. 4 metres. If you opt to connect the stove with an elbow pipe, you should use a curved elbow, as this gives a better draught. If you connect the stove with a sharp elbow pipe, the cleansing lid must be placed in the vertical part so that the horizontal part can be cleaned through here. If the chimney is fitted with a smoke extractor, it must be possible to adjust it to a suitable draft. The requirements...

 Open the catalog to page 11
SCAN 67 1300-12

REMOVAL OF PACKAGING Check that the stove is not damaged before starting to install it. The stove comes attached to a wooden pallet on delivery. NAVN:Krog Scan 67 Iversen DK-5492 Vissenbjerg© MATERIALE: DIMENSION: STI: Krog Iversen & Co A/S DK-5492 Vissenbjerg© Continued on next page 12

 Open the catalog to page 12
SCAN 67 1300-13

Scan 67 - Palle VÆGT: 417,91 AREAL: Lift off the front of the base Rotate 5O and remove the cover plate in the base Krog Iversen & Co A/S DK-5492 Vissenbjerg© The LED is placed loose inside the stove and must be mounted before the front plate is fitted. Press the LED down until it "clicks"

 Open the catalog to page 13
SCAN 67 1300-14

REMOVAL OF TRANSPORT PROTECTION Note that the baffle plates are made of porous, ceramic material, and can break. Exercise care when working. Lift the upper baffle plate and remove protection Transport protection Transportbeskyttelse ved røgvenderstift VÆGT: 433,97 MATERIALE: AREAL: TG.NR: DATO: Mount again the upper baffle plate with the accompanying pin and the lower baffle plate is fitted afterwards Afmontage nederste røgvenderplade NAVN: VÆGT: N/A ATERIALE: AREAL: Turn the baffle plate 90°, and lower it out through the combustion chamber Lift the lower baffle plate, remove transport protection...

 Open the catalog to page 14

All Scan A/S catalogs and technical brochures

  1. SCAN 68-10

    44  Pages

  2. SCAN 66-2

    40  Pages

  3. SCAN 66-1 WALL

    40  Pages

  4. SCAN 65-1

    36  Pages

  5. SCAN 5005 FRL

    36  Pages

  6. SCAN 5003 S FR

    40  Pages

  7. SCAN 5004 FL

    44  Pages

  8. SCAN 5003 FL

    36  Pages

  9. SCAN 1006 CS

    3  Pages

  10. SCAN 41-1

    32  Pages

  11. SCAN 1003 CS

    44  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.