Introduction
This document provides comprehensive instructions for the safe and efficient operation of a Scan wood-burning stove, emphasizing the importance of following guidelines for assembly and use.
Technical Data
  • Installation: Must comply with national and local building regulations, with inspection by a chimney sweep.
  • Specifications: Made of steel and cast iron, with a maximum wood length of 33 cm and a nominal output of 5 kW.
  • Efficiency: 78% efficiency with an energy class of A.
Assembly
  • Tools Required: Spirit level, wall drill, open-end spanner, cutting nippers, and Allen key.
  • Contents: Includes stove body, vermiculite plates, baffle plate pins, and a log guard.
  • Disposal: Recycle or properly dispose of packaging materials.
Instructions for Use
  • CB-Technology: Utilizes Clean Burn technology for efficient combustion.
  • Air Control: Features primary and secondary air controls for optimal burning.
Instructions for Heating
  • Environmentally-Friendly Firing: Use the top-down lighting method.
  • Weather Conditions: Adjust usage based on weather, especially in spring or autumn.
Handling of Fuel
  • Wood Selection: Use approved wood types with appropriate moisture content.
  • Storage: Store wood properly to maintain low moisture levels.
Maintenance
  • Cleaning: Regularly sweep the chimney and clean the stove.
  • Servicing: Check gaskets and painted surfaces for wear.
Troubleshooting
Common issues and solutions are provided for user reference.
Warranty
Details on warranty coverage and conditions are included.
Connection Between Stove and Steel Chimney
Consult with a Scan dealer or local chimney sweep to select the appropriate steel chimney.
Chimney Requirements
The chimney must have a T400 designation and a G rating for the soot fire test, with specific dimensions and safety distances.
Fresh Air Intake
Ensure air exchange in well-insulated homes, with compliance to building regulations.
Closed Combustion System
Recommended for airtight homes, involving external combustion air connection.
Distance to Furniture
Maintain a distance of 850 mm from the stove glass to furniture.
Firewood Storage
Store wood at least 100 mm from the stove.
Safety Distance
Comply with safety distance regulations for wood-burning stoves.
Fitting the Flue Connection Piece
Instructions for top and rear outlet connections are provided.
Height Adjustment of Stove
Leveling is crucial for optimal door function.
Mounting of Wall-Hung Model
Installation must comply with building regulations and involve a building expert and chimney sweep.
Specifications and Design Information
Includes design files for mounting components, identified by unique technical numbers.
Mounting Procedures
  • Wall-Hung Model: Involves gliding rails, mounting plates, and securing screws.
  • Pedestal Base: Instructions for mounting the burn chamber and external air supply.
  • S-Base: Steps for mounting the burn chamber on the S-base.
Floor Plate and Load-Bearing Foundation
Advises on floor plates and load-bearing foundations, emphasizing compliance with local regulations.
Combustion Chamber and CB Technology
Features CB technology for optimal combustion, with instructions on airflow settings.
Environmental Considerations
Guidelines for environmentally-friendly firing, maintaining visible flames for effective combustion.
Lighting
Recommended "top down" lighting method for environmental friendliness and clean glass.
Continuous Operation
Achieving high temperature in the combustion chamber is crucial for efficiency.
Weather Conditions
Adjust airflow based on weather conditions.
Chimney Function
Ensure chimney reaches operating temperature quickly and check for blockages.
Fuel Handling
Use dry wood with a moisture content of 15-18% for best efficiency.
Maintenance
Regular cleaning and servicing are essential, with checks for cracks and worn gaskets.
Troubleshooting
Solutions for common issues like smoke escaping and soot build-up are provided.
Disposal
Dispose of stove parts responsibly, with specific instructions for different materials.
Common Issues and Solutions
Includes causes and solutions for issues like insufficient chimney draw and excessive soot build-up.
Door Adjustment
Instructions for adjusting the door if it does not close properly.
Warranty Information
5-year warranty on manufacturing errors, with exclusions for wear and tear and improper use.
Important Notes
Always use original or manufacturer-recommended replacement parts.
See more

Catalog excerpts

SCAN 66-2-1

EU - ASSEMBLY AND INSTRUCTIONS MANUAL ASSEMBLY AND INSTRUCTIONS MANUAL SCAN 66

 Open the catalog to page 1
SCAN 66-2-2

CONGRATULATIONS ON YOUR NEW SCAN WOOD-BURNING STOVE You have purchased a product by one of Europe’s leading manufacturers of wood-burning stoves, and we are sure that you will have years of pleasure from your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions. Read through this Assembly and Instruction Manual carefully before you start to assemble your stove. SCAN 66-2 PEDESTAL BASE SCAN 66-4 PLINTH BASE SCAN 66-5 S-CURVE BASE

 Open the catalog to page 2
SCAN 66-2-3

Technical data and dimensions 4 Dimension sketch and minimum distances 6 5 Product registration number 8 ■ ASSEMBLY Tools needed for mounting of the stove 9 Existing chimney and pre-fabricated element chimney 10 Connection between stove and steel chimney 10 Closed combustion system 11 CB-technology (Clean Burn) 27 Fitting the flue connection piece 14 Height adjustment of stove 16 Mounting of wall-hung model 17 Mounting of the burn chamber on the pedestal base 21 Mounting of external air supply on the pedestal base 21 Mounting of the burn chamber on the plinth base 22 Mounting of external air...

 Open the catalog to page 3
SCAN 66-2-4

TECHNICAL DATA INSTALLATION ¬ The house owner is responsible for ensuring that installation and assembly are in accordance with national and local building regulations as well as the information provided in this Assembly and Instruction Manual ¬ When you install any kind of fireplace or stove, you must inform the local building and housing authorities. In addition you are obliged to have the installation inspected and approved by a local chimney sweep prior to commissioning ¬ To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter. Your...

 Open the catalog to page 4
SCAN 66-2-5

Steel plate Cast iron Galvanised sheet Vermiculite Surface treatment Connecting piece internal diameter 144 mm Connecting piece external diameter 148 mm Fresh air connection piece external diameter Approval type Intermittent fuelling* * Intermittent operation in this context means normal use of a wood-burning stove. In other words, you should let the fire die down until only the embers are left before refueling. This stove is produced in accordance with type approval for the product, which also covers the product's Assembly and Instruction Manual. The Declaration of Performance (DoP) is available...

 Open the catalog to page 5
SCAN 66-2-6

All distances are in mm. All distances are minimum distances * Connection of fresh-air intake - external diameter Ø 100 mm ** Min. distance to furniture/flammable material *** Height to the beginning of flue connecting piece at top outlet Flammable material Målskitse Scan 66-1 væghængt Målskitse Scan 66-2 Pedistal Radiation zone 434* X / Y according to national laws and regulations Floor plate Målskitse Scan 66-4 Plint DIMENSION SKETCH AND MINIMUM DIS

 Open the catalog to page 6
SCAN 66-2-7

NAVN: TG.NR: Målskitse - væghængt (afstand til brændbart) The wall model is only to be mounted on a non-combustible wall! w Afstand til brændbart - isoleret Minimum distance to flammable floor90066005B id B. 07 KEN N/A 06-01-2021 60 (wall model) 06 0 9 AREAL: \ 66 an 66\90066005B.idw STI: C:\Working cFolder\Designs\Scan \S s n ig es \D er ld o F g in rk DIMENSION: Minimum distance to flammable materials (insulated flue pipe) 150 DK-5492 Vissenbjerg© STI: C:\Working Folder\Designs\Scan 66\90066015B.idw DIMENSION: Krog Iversen & Co A/S 6 All distances are in mm. an Sc : All distances are minimum...

 Open the catalog to page 7
SCAN 66-2-8

TYPE PLATE All Scan wood-burning stoves are fitted with a type plate that specifies the approval standards and the distance to flammable materials. The type plate is located at the rear of the stove. Typeplate Type plate Product registration number MATERIALE: AREAL: PRODUCT REGISTRATION NUMBER All Scan wood-burning stoves are provided with a product registration number. Please make a note of this number at the rear page of this manual; you will always need to quote it when contacting your dealer or Scan A/S. Product registration number The product registration number is located at the rear of...

 Open the catalog to page 8
SCAN 66-2-9

ASSEMBLY TOOLS NEEDED FOR MOUNTING OF THE STOVE ¬ Spirit level CONTENTS OF PACKAGING ¬ 1 Scan 66 stove body ¬ 6 vermiculite plates ¬ 2 pins for baffle plates ¬ 1 connecting piece for fresh air inlet ¬ 1 log guard made of glass Krog Iversen & Co A/S DK-5492 Vissenbjerg© LOOSE PARTS In the stoves combustion chamber you will find the following loose parts: NAVN: ¬ 4 pcs. screws for connecting piece/fresh air MATERIALE: DIMENSION: ¬ Repair lacquer for coloured stoves inkl. skamol ¬ Small shaped floor plate in glassVÆGT: or steel N/A (steel only for Scan 66-2 & 66-5) DIM.: Skamol enkeltdele HMS N/A...

 Open the catalog to page 9
SCAN 66-2-10

Your Scan stove may come supplied with the following packaging: If you intend to connect your stove to an existing chimney, it makes sense to contact an authorised Scan dealer, or a local chimney sweep, for advice. These experts will also let you know if your chimney needs renovating. - When connecting a prefabricated element chimney, follow the manufacturer's connection instructions for the relevant chimney type Your Scan dealer, or local chimney sweep, can advise you on choosing a make and type of steel chimney. This ensures that the chimney will match your wood-burning stove. The chimney must...

 Open the catalog to page 10
SCAN 66-2-11

CLOSED COMBUSTION SYSTEM You should use the closed combustion system for the wood-burning stove if you live in a newly-built, airtight home. External combustion air is connected through a ventilation pipe via the wall or floor. We recommend mounting a valve in the ventilation pipe in order to avoid condensate in the stove and the pipe system, when the stove is not in use. It can also be an advantage to insulate the ventilation pipe. Minimum Ø 100 mm ventilation pipe, maximum length: 6 metres with a maximum of one bend. We recommend smooth steel pipes. Connecting piece for fresh air inlet is loose...

 Open the catalog to page 11

All Scan A/S catalogs and technical brochures

  1. SCAN 68-10

    44  Pages

  2. SCAN 67 1300

    36  Pages

  3. SCAN 66-1 WALL

    40  Pages

  4. SCAN 65-1

    36  Pages

  5. SCAN 5005 FRL

    36  Pages

  6. SCAN 5003 S FR

    40  Pages

  7. SCAN 5004 FL

    44  Pages

  8. SCAN 5003 FL

    36  Pages

  9. SCAN 1006 CS

    3  Pages

  10. SCAN 41-1

    32  Pages

  11. SCAN 1003 CS

    44  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.