Open the catalog to page 1CONGRATULATIONS ON YOUR NEW SCAN BUILT-IN STOVE You have purchased a product by one of Europe’s leading manufacturers of wood-burning stoves, and we are sure that you will have years of pleasure from your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions. Read through this Assembly and Instruction Manual carefully before you start to assemble your stove.
Open the catalog to page 24 Dimension sketch Scan 5004 FR/FL Technical data and dimensions Additional accessories Disposal of packaging Load-bearing foundation Floor plate Existing chimney and prefabricated element chimney Connection between built-in stove and steel chimney Requirements for chimney Trim Internal installation in non-flammable material Minimum distance to flammable materials Building in the stove at a fire wall Safety distance Building into flammable material with fire wall 8 Before building the insert 8 Closed combustion system 8 Clips for Norway (Large rooms) 9 Mounting of the heat shields/convection...
Open the catalog to page 3TECHNICAL DATA INSTALLATION ¬ The house owner is responsible for ensuring that installation and assembly are in accordance with national and local building regulations as well as the information provided in this Assembly and Instructions Manual ¬ When you install any kind of fireplace or stove, you must inform the local building and housing authorities. In addition you are obliged to have the installation inspected and approved by a local chimney sweep prior to commissioning ¬ To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter....
Open the catalog to page 4Steel plate Cast iron Galvanised sheet Chamotte TECHNICAL DATA AND DIMENSIONS Materials Surface treatment Weight Scan 5004 FR/FL Weight Scan 5004 FR/FL w/heat shield Flue conn. piece internal diameter Flue conn. piece external diameter Approval type * Intermittent operation in this context means normal use of a built-in stove. In other words, you should let the fire die down until only the embers are left before refuelling. This built-in stove is produced in accordance with type approval for the product, which also covers the product's Assembly and Instruction Manual. The Declaration of Performance...
Open the catalog to page 5DIMENSION SKETCH SCAN 5004 FR/FL A Height to the beginning of flue connecting piece at top outlet Centre of fresh air intake - Inside measure: 133 mm, Outside measure: 149 mm Flue conn. piece - Inside measure: 175 mm, Outside measure: 200 mm All measures are in mm *NB – remember to check the distance to flammable materials. *Note: Refer to the manual for distance to combustible floor. Drawing
Open the catalog to page 6TYPE PLATE All Scan built-in stoves are fitted with a type plate that specifies the approval standards and the distance to flammable materials. The type plate is placed loose in the fireplace. Type plate Scan 5004 FR/FL PRODUCT REGISTRATIONUMBER All Scan built-in stoves are provided with a product registration number. Please make a note of this number at the rear page of this manual; you will always need to quote it when contacting your dealer or Scan A/S. Product registration number Scan 5004 FR/FL
Open the catalog to page 7■ Fresh air box 0149 cm (see page 12) ■ Heat-storage stones (see page 14) ■ Heat shields/convection covers (see page 15) ■ Frames (see page 19) ■ Braces with frames (see page 24) ■ Convection air grid (see page 31) Your Scan built-in stove may come supplied with the following packaging: All items in our product range come under the category of lightweight fireplaces and stoves and do not normally require any reinforcement of the beam structure. They can be positioned on ordinary beams/floor. You should of course make sure that the foundation on which the stove is positioned can indeed support...
Open the catalog to page 8REQUIREMENTS FOR CHIMNEY The chimney must have a minimum internal diameter of 190 mm and have a T400 designation, with G for the soot fire test. The length should be min. 5 metres. If you opt to connect the built-in stove with an elbow pipe, you should use a curved elbow, as this gives a better draught. If you connect the stove with a sharp elbow pipe, the cleansing lid must be placed in the vertical part so that the horizontal part can be cleaned through here. If the chimney is fitted with a smoke extractor, it must be possible to adjust it to a suitable draft. The requirements to the chimney...
Open the catalog to page 9BUILDING INTO FLAMMABLE MATERIAL WITH FIRE WALL Building in the Scan 5004 FR/FL with radiation shields against a flammable wall protected by a fire wall. Installation with an insulated, vertical flue pipe Flammable material Fire wall, e.g. 50 mm Jøtul Firewall, 110 mm brick or other material with corresponding fireproof and insulating abilities All distances are in mm. All distances are minimum distances * Distance to glass DATO: SIGN: *** Distance to furniture fromKEN glass 23-01-2019 Upper convection opening Insulated length Lower convection opening Alle mål er minimusmål. Installation with...
Open the catalog to page 10BUILDING INTO FLAMMABLE MATERIAL WITH FIRE WALL The two cover plates in the front must be removed, when you build the stove into a flammable wall. Indbygning i brandmur,Scan 5004 FR/FL VÆGT: N/A BEFORE BUILDING THE INSERT M3 NR.: TG.NR: DATO: IMPORTANT! Before the insert is built in, the bolt in the side of the insertDK-5492 shouldVissenbjerg© be removed. Folder\Designs\Scan 5004\95004016.idw STI: C:\Working Indbygning i brandmur,Scan 5004 FR/FL VÆGT: N/A Transportsikring, låge, Scan 5004 FR/FL VÆGT: N/A TG.NR: DATO: TG.NR: DATO:
Open the catalog to page 11FRESH AIR INTAKE In a well-insulated house the air used for the combustion process has to be replaced. This particularly applies to houses with mechanical ventilation. There are different ways of making sure that air is exchanged. The most important thing is to ensure that there is a supply of air to the room where the built-in stove is located. The external wall vent must be located as close to the stove as possible, and you must be able to close it when you are not using the stove. National and local building regulations must be followed with regard to connection of a fresh air intake. CLOSED...