1. Catalogs
  2. Scan A/S
  3. SCAN 5004 FL

SCAN 5004 FL

SCAN 5004 FL
1 / 44 PagesView full catalog

SCAN 5004 FL

Product catalog summary
Introduction
This document is a manual for a wood-burning stove from a leading European manufacturer, providing essential instructions for assembly, use, and safety to ensure optimal performance.

Technical Data
The stove complies with EN 13229 standards, has an efficiency of 85%, an energy efficiency class of A+, and a nominal output of 6.9 kW. It requires a combustion air supply of 20-35 m3/h and is designed for wood fuel with a maximum log length of 45 cm.

Installation
Installation must adhere to national and local building regulations, with a recommendation for inspection by a local chimney sweep. The chimney should have a minimum internal diameter of 190 mm and a length of at least 5 meters.

Safety
Modifications or non-approved accessories can compromise safety. Maintain specified distances from flammable materials: 400 mm from sides and back, 800 mm from glass and ceiling.

Assembly
Ensure the foundation supports the stove's weight. Use a non-flammable floor plate if placed on a flammable surface. Follow guidelines for connecting to chimneys.

Instructions for Use
Use the top-down lighting method, ensure proper combustion air supply, and avoid over-firing. Adjust usage based on weather conditions.

Maintenance
Regularly sweep the chimney and clean the stove. Check gaskets and painted surfaces for wear. Dispose of stove parts responsibly.

Troubleshooting and Warranty
Refer to the troubleshooting section for common issues. The warranty details are provided for reference.

Installation Instructions
Details for installing the Scan 5004 convection grate include cutting a hole in the wall, fastening the metal frame, and mounting magnets. Proper convection air areas are crucial to prevent damage.

Convection Air Requirements
Minimum area for ingoing convection air is 500 cm² and for outgoing convection air is 750 cm². Convection air grids are available as accessories.

Heating Instructions
Use fire lighters for environmentally friendly operation and avoid over-firing. The "top down" lighting method is recommended for cleaner combustion.

Weather Conditions
Discusses the impact of wind and weather on chimney performance and suggests adjustments to airflow and the use of a damper.

Continuous Operation
Maintain high temperatures for efficient combustion and avoid smoke. Guidelines for adding wood and managing airflow are provided.

Chimney Function and Maintenance
Emphasizes the importance of chimney performance, temperature differences, and regular checks and cleaning. Instructions for handling chimney fires are included.

Fuel Handling
Discusses the calorific value of different wood types and the importance of using dry wood with a moisture content of 15-18%. Prohibits the use of treated or painted wood.

Specifications and Maintenance
Outlines maintenance procedures, emphasizing replacing worn gaskets and cleaning painted surfaces with a dry, lint-free cloth.

Combustion Chamber Lining Replacement
Provides detailed instructions for replacing the combustion chamber lining, including the placement of chamotte plates and baffle fittings.

Disposal Instructions
Different materials from the stove have specific disposal methods: steel/cast iron should be recycled, glass as ceramic waste, and vermiculite/chamotte as non-recyclable waste.

Cleaning Procedures
To prevent soot build-up on the glass, ensure a good supply of combustion air and use dry wood. Clean the glass with a dry cloth followed by a damp cloth with glass cleaner.

Troubleshooting
Common issues include smoke escaping, wood burning too quickly, soot build-up, and poor heating performance. Solutions involve checking wood quality, chimney dimensions, and airflow settings.

Warranty Information
A 5-year warranty covers manufacturing defects but excludes wear and tear parts, external damage, and improper use. The warranty is non-transferable and void under certain conditions.

Additional Notes
Includes a reminder to quote the product registration number for warranty claims and inquiries.
See more

Catalog excerpts

SCAN 5004 FL-1

UK - ASSEMBLY AND INSTRUCTIONS MANUAL ASSEMBLY AND INSTRUCTION MANUAL SCAN 5004 FR/FL

 Open the catalog to page 1
SCAN 5004 FL-2

CONGRATULATIONS ON YOUR NEW SCAN BUILT-IN STOVE You have purchased a product by one of Europe’s leading manufacturers of wood-burning stoves, and we are sure that you will have years of pleasure from your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions. Read through this Assembly and Instruction Manual carefully before you start to assemble your stove.

 Open the catalog to page 2
SCAN 5004 FL-3

4 Dimension sketch Scan 5004 FR/FL Technical data and dimensions Additional accessories Disposal of packaging Load-bearing foundation Floor plate Existing chimney and prefabricated element chimney Connection between built-in stove and steel chimney Requirements for chimney Trim Internal installation in non-flammable material Minimum distance to flammable materials Building in the stove at a fire wall Safety distance Building into flammable material with fire wall 8 Before building the insert 8 Closed combustion system 8 Clips for Norway (Large rooms) 9 Mounting of the heat shields/convection...

 Open the catalog to page 3
SCAN 5004 FL-4

TECHNICAL DATA INSTALLATION ¬ The house owner is responsible for ensuring that installation and assembly are in accordance with national and local building regulations as well as the information provided in this Assembly and Instructions Manual ¬ When you install any kind of fireplace or stove, you must inform the local building and housing authorities. In addition you are obliged to have the installation inspected and approved by a local chimney sweep prior to commissioning ¬ To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter....

 Open the catalog to page 4
SCAN 5004 FL-5

Steel plate Cast iron Galvanised sheet Chamotte TECHNICAL DATA AND DIMENSIONS Materials Surface treatment Weight Scan 5004 FR/FL Weight Scan 5004 FR/FL w/heat shield Flue conn. piece internal diameter Flue conn. piece external diameter Approval type * Intermittent operation in this context means normal use of a built-in stove. In other words, you should let the fire die down until only the embers are left before refuelling. This built-in stove is produced in accordance with type approval for the product, which also covers the product's Assembly and Instruction Manual. The Declaration of Performance...

 Open the catalog to page 5
SCAN 5004 FL-6

DIMENSION SKETCH SCAN 5004 FR/FL A Height to the beginning of flue connecting piece at top outlet Centre of fresh air intake - Inside measure: 133 mm, Outside measure: 149 mm Flue conn. piece - Inside measure: 175 mm, Outside measure: 200 mm All measures are in mm *NB – remember to check the distance to flammable materials. *Note: Refer to the manual for distance to combustible floor. Drawing

 Open the catalog to page 6
SCAN 5004 FL-7

TYPE PLATE All Scan built-in stoves are fitted with a type plate that specifies the approval standards and the distance to flammable materials. The type plate is placed loose in the fireplace. Type plate Scan 5004 FR/FL PRODUCT REGISTRATIONUMBER All Scan built-in stoves are provided with a product registration number. Please make a note of this number at the rear page of this manual; you will always need to quote it when contacting your dealer or Scan A/S. Product registration number Scan 5004 FR/FL

 Open the catalog to page 7
SCAN 5004 FL-8

■ Fresh air box 0149 cm (see page 12) ■ Heat-storage stones (see page 14) ■ Heat shields/convection covers (see page 15) ■ Frames (see page 19) ■ Braces with frames (see page 24) ■ Convection air grid (see page 31) Your Scan built-in stove may come supplied with the following packaging: All items in our product range come under the category of lightweight fireplaces and stoves and do not normally require any reinforcement of the beam structure. They can be positioned on ordinary beams/floor. You should of course make sure that the foundation on which the stove is positioned can indeed support...

 Open the catalog to page 8
SCAN 5004 FL-9

REQUIREMENTS FOR CHIMNEY The chimney must have a minimum internal diameter of 190 mm and have a T400 designation, with G for the soot fire test. The length should be min. 5 metres. If you opt to connect the built-in stove with an elbow pipe, you should use a curved elbow, as this gives a better draught. If you connect the stove with a sharp elbow pipe, the cleansing lid must be placed in the vertical part so that the horizontal part can be cleaned through here. If the chimney is fitted with a smoke extractor, it must be possible to adjust it to a suitable draft. The requirements to the chimney...

 Open the catalog to page 9
SCAN 5004 FL-10

BUILDING INTO FLAMMABLE MATERIAL WITH FIRE WALL Building in the Scan 5004 FR/FL with radiation shields against a flammable wall protected by a fire wall. Installation with an insulated, vertical flue pipe Flammable material Fire wall, e.g. 50 mm Jøtul Firewall, 110 mm brick or other material with corresponding fireproof and insulating abilities All distances are in mm. All distances are minimum distances * Distance to glass DATO: SIGN: *** Distance to furniture fromKEN glass 23-01-2019 Upper convection opening Insulated length Lower convection opening Alle mål er minimusmål. Installation with...

 Open the catalog to page 10
SCAN 5004 FL-11

BUILDING INTO FLAMMABLE MATERIAL WITH FIRE WALL The two cover plates in the front must be removed, when you build the stove into a flammable wall. Indbygning i brandmur,Scan 5004 FR/FL VÆGT: N/A BEFORE BUILDING THE INSERT M3 NR.: TG.NR: DATO: IMPORTANT! Before the insert is built in, the bolt in the side of the insertDK-5492 shouldVissenbjerg© be removed. Folder\Designs\Scan 5004\95004016.idw STI: C:\Working Indbygning i brandmur,Scan 5004 FR/FL VÆGT: N/A Transportsikring, låge, Scan 5004 FR/FL VÆGT: N/A TG.NR: DATO: TG.NR: DATO:

 Open the catalog to page 11
SCAN 5004 FL-12

FRESH AIR INTAKE In a well-insulated house the air used for the combustion process has to be replaced. This particularly applies to houses with mechanical ventilation. There are different ways of making sure that air is exchanged. The most important thing is to ensure that there is a supply of air to the room where the built-in stove is located. The external wall vent must be located as close to the stove as possible, and you must be able to close it when you are not using the stove. National and local building regulations must be followed with regard to connection of a fresh air intake. CLOSED...

 Open the catalog to page 12

All Scan A/S catalogs and technical brochures

  1. SCAN 68-10

    44  Pages

  2. SCAN 67 1300

    36  Pages

  3. SCAN 66-2

    40  Pages

  4. SCAN 66-1 WALL

    40  Pages

  5. SCAN 65-1

    36  Pages

  6. SCAN 5005 FRL

    36  Pages

  7. SCAN 5003 S FR

    40  Pages

  8. SCAN 5003 FL

    36  Pages

  9. SCAN 1006 CS

    3  Pages

  10. SCAN 41-1

    32  Pages

  11. SCAN 1003 CS

    44  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.