SCAN 5003 FL

SCAN 5003 FL
1 / 36 PagesView full catalog

SCAN 5003 FL

Product catalog summary
Introduction
This document provides essential information for the installation, operation, and maintenance of a wood-burning stove from a leading European manufacturer. Proper adherence to the manual ensures optimal use and longevity of the stove.
Technical Data
The stove meets EN 13229 standards with an efficiency of 85% and an energy efficiency class of A+. It has a nominal output of 5.7 kW and requires a chimney with a minimum internal diameter of 148 mm.
Installation
Installation must comply with national and local building regulations. It is recommended to have the installation inspected by a local chimney sweep and performed by a professional fitter for safety and optimal functionality.
Safety
Modifications or use of non-supplied accessories can impair safety. The stove should not be installed in flammable materials without appropriate firewalls and heat shields.
Assembly
The foundation must support the stove's weight, and a non-flammable floor plate is required if placed on a flammable floor. The chimney must be at least 5 meters long.
Instructions for Use
Use the top-down lighting method for efficient combustion. Ensure proper air supply and avoid over-firing to maintain performance and safety.
Maintenance
Regular chimney sweeping and stove cleaning are necessary. Periodically check gaskets and painted surfaces for wear.
Troubleshooting and Warranty
Refer to the troubleshooting section for common issues. The stove comes with a 5-year warranty covering manufacturing defects, excluding wear parts like liners and gaskets.
Specifications and Procedures
The document details technical specifications and procedures for installation and operation, including fresh air intake systems and closed combustion systems. It provides instructions for mounting heat shields and convection covers.
Fresh Air Intake and Closed Combustion System
In well-insulated homes, ensure a fresh air supply for combustion. The document specifies the diameter for fresh air connections and recommends a closed combustion system in airtight homes.
Mounting Instructions
Instructions for mounting heat shields and convection covers emphasize proper air circulation for effective heat distribution.
Instructions for Use
Environmentally friendly operation is emphasized, advising against reducing the stove to the point where no flames are visible. The "top down" lighting method is recommended for efficient combustion.
Continuous Operation
Maintaining a high temperature in the combustion chamber is crucial for optimal performance and clean combustion.
Specifications and Recommendations
Use the correct amount and type of wood for optimal performance. The combustion air flow should be fully open to ensure quick ignition.
Chimney Function and Maintenance
The chimney is vital for stove performance, requiring regular maintenance to ensure proper function and safety.
Fuel Handling
Hardwoods like beech and ash are recommended for their high calorific value. Wood should be dry, with a moisture content of 15-18%.
Maintenance and Servicing
Regular cleaning and servicing are recommended. The combustion chamber lining and gaskets are not covered by warranty and should be replaced as needed.
Troubleshooting
Common issues include smoke escaping and soot build-up, with solutions involving air valve adjustments and using dry wood.
Warranty Information
The 5-year warranty covers manufacturing defects but excludes wear parts. It is void in cases of improper installation or unauthorized repairs.
See more

Catalog excerpts

SCAN 5003 FL-1

UK - ASSEMBLY AND INSTRUCTIONS MANUAL ASSEMBLY AND INSTRUCTION MANUAL SCAN 5003 FR/FL

 Open the catalog to page 1
SCAN 5003 FL-2

CONGRATULATIONS ON YOUR NEW SCAN BUILT-IN STOVE You have purchased a product by one of Europe’s leading manufacturers of woodburning stoves, and we are sure that you will have years of pleasure from your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions. Read through this Assembly and Instruction Manual carefully before you start to assemble your stove.

 Open the catalog to page 2
SCAN 5003 FL-3

9 Cutout in the surround material 9 Closed combustion system 9 Clips for Norway (Large rooms) 10 Mounting of the heat shields/convection covers 10 Mounting of convection grate CONTENTS■ TECHNICAL DATA Installation 4 Dimension sketch and minimum distances Safety 4 Type plate Technical data and dimensions 5 Product registration number Additional accessories Disposal of packaging Load-bearing foundation Floor plate Existing chimney and pre-fabricated element chimney Connection between built-in stove and steel chimney Requirements for chimney Balanced flue Trim Internal installation in non-flammable...

 Open the catalog to page 3
SCAN 5003 FL-4

TECHNICAL DATA INSTALLATION ¬ The house owner is responsible for ensuring that installation and assembly are in accordance with national and local building regulations as well as the information provided in this Assembly and Instructions Manual ¬ When you install any kind of fireplace or stove, you must inform the local building and housing authorities. In addition you are obliged to have the installation inspected and approved by a local chimney sweep prior to commissioning ¬ To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter....

 Open the catalog to page 4
SCAN 5003 FL-5

Steel plate Cast iron Galvanised sheet Chamotte TECHNICAL DATA AND DIMENSIONS Materials Surface treatment Weight Scan 5003 FR/FL Weight Scan 5003 FR/FL w/heat shield Flue conn. piece internal diameter Flue conn. piece external diameter Approval type * Intermittent operation in this context means normal use of a built-in stove. In other words, you should let the fire die down until only the embers are left before refuelling. This built-in stove is produced in accordance with type approval for the product, which also covers the product's Assembly and Instruction Manual. The Declaration of Performance...

 Open the catalog to page 5
SCAN 5003 FL-6

Weight: N/A Area: N/A Folder\Designs\Scan 5003\95003001.idw All distances are in mm. All distances are minimum distances * Connection of fresh-air intake - inside measure: Ø 103 mm - outside measure: Ø120 mm ** Min. distance to furniture/flammable material *** Height to the beginning of flue connecting piece at top/rear outlet, flue conn. piece - inside measure: Ø132 mm - outside measure: Ø149 mm Flammable material number: Drawing sr number: Målskitse, FR, varmeskjold til brandmur *Note: Refer to the manual for distance *Note: Referto tocombustible the manual floor. for distance to combustible...

 Open the catalog to page 6
SCAN 5003 FL-7

Fire wall, e.g. 50 mm Jøtul Firewall, 110 mm brick or other material with corresponding fireproof and insulating abilities Insulated length Upper convection opening EMNE: Scan 5003 Scan A/S MATERIALE:DK-5492 Vissenbjerg© NAVN: Brandmur F.eks. 50 mm Jøtul firewall, 110 mm mursten eller andet materiale med tilsvarende brandfasthed og isolationsevne. Min. 500 cm2 Brandbart materiale All distances are in mm. All distances are minimum distances These distances apply for an insulated flue pipe all the way down to the stove * Distance to glass ** Distance to flammable floor Cavities are not to be filled...

 Open the catalog to page 7
SCAN 5003 FL-8

TYPE PLATE All Scan built-in stoves are fitted with a type plate that specifies the approval standards and the distance to flammable materials. The type plate is placed loose in the fireplace. Type plate Scan 5003 FR/FL PRODUCT REGISTRATION NUMBER All Scan built-in stoves are provided with a product registration number. Please make a note of this number at the rear page of this manual; you will always need to quote it when contacting your dealer or Scan A/S. Product registration number Scan 5003 FR/FL

 Open the catalog to page 8
SCAN 5003 FL-9

■ Fresh air box (see page 12) ■ Connection pipe 0 100 mm ■ Heat-storage stones (see page 13) ■ Heat shields/convection covers (see page 14) ■ Frames (see page 18) ■ Convection air grid (see page 21) Your Scan built-in stove may come supplied with the following packaging: All items in our product range come under the category of lightweight fireplaces and stoves and do not normally require any reinforcement of the beam structure. They can be positioned on ordinary beams/floor. You should of course make sure that the foundation on which the stove is positioned can indeed support the weight of the...

 Open the catalog to page 9
SCAN 5003 FL-10

REQUIREMENTS FOR CHIMNEY The chimney must have a minimum internal diameter of 148 mm and have a T400 designation, with G for the soot fire test. The length should be min. 5 metres. If you opt to connect the built-in stove with an elbow pipe, you should use a curved elbow, as this gives a better draught. If you connect the stove with a sharp elbow pipe, the cleansing lid must be placed in the vertical part so that the horizontal part can be cleaned through here. If the chimney is fitted with a smoke extractor, it must be possible to adjust it to a suitable draft. The requirements to the chimney...

 Open the catalog to page 10
SCAN 5003 FL-11

CUTOUT IN THE SURROUND MATERIAL If you want to build in the insert so that the surround is flush with the insert's door, it may be necessary - according to the thickness of the material - to make a cut in the material to allow space for the box on the front. TG.NR: DATO: Udskæring i firewall for kasse TG.NR: DATO: Scan A/S DK-5492 Vissenbjerg© NAVN: Udskæring i firewall for kasse VÆGT: N/A TG.NR: DATO:

 Open the catalog to page 11
SCAN 5003 FL-12

FRESH AIR INTAKE In a well-insulated house the air used for the combustion process has to be replaced. This particularly applies to houses with mechanical ventilation. There are different ways of making sure that air is exchanged. The most important thing is to ensure that there is a supply of air to the room where the built-in stove is located. The external wall vent must be located as close to the stove as possible, and you must be able to close it when you are not using the stove. National and local building regulations must be followed with regard to connection of a fresh air intake. The...

 Open the catalog to page 12

All Scan A/S catalogs and technical brochures

  1. SCAN 68-10

    44  Pages

  2. SCAN 67 1300

    36  Pages

  3. SCAN 66-2

    40  Pages

  4. SCAN 66-1 WALL

    40  Pages

  5. SCAN 65-1

    36  Pages

  6. SCAN 5005 FRL

    36  Pages

  7. SCAN 5003 S FR

    40  Pages

  8. SCAN 5004 FL

    44  Pages

  9. SCAN 1006 CS

    3  Pages

  10. SCAN 41-1

    32  Pages

  11. SCAN 1003 CS

    44  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.