SCAN 41-1
1 /32Pages

SCAN 41-1

SCAN 41-1
1 /32Pages

Catalog excerpts

SCAN 41-1-1

EU - ASSEMBLY AND INSTRUCTIONS MANUAL ASSEMBLY AND INSTRUCTIONS MANUAL SCAN 41

 Open the catalog to page 1
SCAN 41-1-2

CONGRATULATIONS ON YOUR NEW SCAN WOOD-BURNING STOVE You have purchased a product by one of Europe’s leading manufacturers of wood-burning stoves, and we are sure that you will have years of pleasure from your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions. Read through this Assembly and Instruction Manual carefully before you start to assemble your stove.

 Open the catalog to page 2
SCAN 41-1-3

Technical data and dimensions 4 Dimension sketch and minimum distances 5 Product registration number ■ ASSEMBLY 10 Height adjustment of stove 11 Fitting the flue connection piece Tools needed for mounting of the stove Loose parts Additional accessories Closed combustion system Existing chimney and pre-fabricated element chimney Connection between built-in stove and steel chimney Requirements for chimney CB-technology (Clean Burn) Environmentally-friendly firing Lighting Continuous operation Warning about over-firing Using your stove in various weather conditions 20 Firing in the spring or autumn...

 Open the catalog to page 3
SCAN 41-1-4

TECHNICAL DATA INSTALLATION ¬ The house owner is responsible for ensuring that installation and assembly are in accordance with national and local building regulations as well as the information provided in this Assembly and Instruction Manual ¬ When you install any kind of fireplace or stove, you must inform the local building and housing authorities. In addition you are obliged to have the installation inspected and approved by a local chimney sweep prior to commissioning ¬ To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter. Your...

 Open the catalog to page 4
SCAN 41-1-5

Surface treatment Weight Scan 41-1 and Scan 41-2 Connecting piece internal diameter Connecting piece external diameter Approval type Steel plate Cast iron Galvanised sheet Vermicolite Scan 41-1 - Test in compliance with EN 13240 Scan 41-2 - Test in compliance with EN 13240 Intermittent operation in this context means normal use of a wood-burning stove. In other words, you should let the fire die down until only the embers are left before refueling. This stove is produced in accordance with type approval for the product, which also covers the product's Assembly and Instruction Manual. The Declaration...

 Open the catalog to page 5
SCAN 41-1-6

Flammable ceiling (All models) Opstillingstegning (afstand til brændbart materiale) Opstillingstegning (afstand til brændbart materiale) Radiation zone X / Y according to national laws and regulations Floor platee All distances are in mm. All distances are minimum distances * Connection of fresh-air intake Ø 100 mm ** Min. distance to furniture/flammable material *** Height to the beginning of flue connecting piece at top outlet Flammable material DIMENSION SKETCH AND MINIMUM D

 Open the catalog to page 6
SCAN 41-1-7

EMNE: Opstilling EMNE: Opstilling 50 mod brændbar væg, ovn uden sideruder MATERIALE: Minimum distance to flammable materials (with side windows) All distances are in mm. All distances are minimum distances * Half-insulated chimney / shielded flue pipe modin brændbar ovn uden sideruder NAVN:requirements EMNE: Scan 64 (The to the chimney andOpstilling the flue pipe terms ofvæg, safety distances must be met) Flammable material Minimum distance to flammable materials (without side windows)

 Open the catalog to page 7
SCAN 41-1-8

TG.NR: SIGN: Flammable material AREAL: 72301695 mm^2 DIMENSION: Krog Iversen & Co A/S Opstillingstegning (afstand til brandmur) Folder\Designs\Scan STI: C:\Working DK-5492 Vissenbjerg© All distances are in mm. DATO: 30-08-2022 SIGN: KEN VÆGT: 903,37 kg MATERIALE: DATO: 30-08-2022 SIGN: KEN VÆGT: 903,37 kg All distances are minimum distances AREAL: 72301695 mm^2 DIMENSION: Krog Iversen & Co A/S AREAL: flue 72301695 mm^2 * Half-insulated chimney / shielded pipe (The requirements to the&chimney Krog Iversen Co A/S and the flue pipe in terms of safety distances must be met) Opstillingstegning (afstand...

 Open the catalog to page 8
SCAN 41-1-9

TYPE PLATE All Scan wood-burning stoves are fitted with a type plate that specifies the approval standards and the distance to flammable materials. The type plate is located at the rear of the stove. Type plate Scan 41-1 (without side windows) Typeskilt Scan 41-2 (without side windows) PRODUCT REGISTRATION NUMBER All Scan wood-burning stoves are provided with a product registration number. Please make a note of this number at the rear page of this manual; you will always need to quote it when contacting your dealer or Scan A/S. The product registration number is located at the rear of the stove....

 Open the catalog to page 9
SCAN 41-1-10

■ Spirit level ■ Open-end spanner The loose parts are located in the stove's ash drawer. ■ Glove ■ Seal for the connecting piece ■ 4 pcs. screws M5x12 mm for fastening the connecting piece ■ 1 pcs. screw M5x6 mm, must be placed for United Kingdom ■ Small shaped floor plate in glass or steel ■ Large shaped floor plate in glass or steel ■ Adjustment key for height adjustment Your Scan stove may come supplied with the following packaging: In a well-insulated house, the air used up by the burning process has to be replaced. This particularly applies to houses with mechanical ventilation. There are...

 Open the catalog to page 10
SCAN 41-1-11

CLOSED COMBUSTION SYSTEM You should use the closed combustion system for the wood-burning stove if you live in a newly-built, airtight home. External combustion air is connected through a ventilation pipe via the wall or floor. It must be possible to shut off the ventilation pipe with a valve, when the stove is not in use. Minimum Ø 100 mm ventilation pipe, maximum length: 6 metres with a maximum of one bend. We recommend smooth steel pipes. We recommend mounting a valve in the ventilation pipe in order to avoid condensate in the stove and the pipe system, when the stove is not in use. It can...

 Open the catalog to page 11
SCAN 41-1-12

DISTANCE TO FURNITURE Distance to furniture from glass: 1000 mm. You should however assess whether furniture or other items might become excessively dry due to being too close to the stove. SAFETY DISTANCE European, national and local regulations concerning safety distances for wood-burning stoves must be complied with. There are no demands concerning the distance to non-flammable materials, but we recommend a distance of 50 mm in order to facilitate the cleaning of the stove, the flue pipes and the chimney and to prevent possible damages to the wall.

 Open the catalog to page 12

All Scan A/S catalogs and technical brochures

  1. SCAN 68-10

    44  Pages

  2. SCAN 67 1300

    36  Pages

  3. SCAN 66-2

    40  Pages

  4. SCAN 66-1 WALL

    40  Pages

  5. SCAN 65-1

    36  Pages

  6. SCAN 5005 FRL

    36  Pages

  7. SCAN 5003 S FR

    40  Pages

  8. SCAN 5004 FL

    44  Pages

  9. SCAN 5003 FL

    36  Pages

  10. SCAN 1006 CS

    3  Pages

  11. SCAN 1003 CS

    44  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.