Introduction
This manual provides essential instructions for the assembly and use of a wood-burning stove from a leading European manufacturer, ensuring optimal performance and safety.
Technical Data
  • Materials: Steel plate, Cast iron, Galvanised sheet, Vermiculite
  • Max. wood length: 30 cm
  • Weight: Approx. 119 kg
  • Efficiency: 82% for Scan 41-1, 79% for Scan 41-2
  • Energy efficiency class: A+ for Scan 41-1, A for Scan 41-2
  • Nominal output: 6 kW
  • Fuel: Wood
Installation
  • Compliance with national and local building regulations is required.
  • Installation must be inspected and approved by a local chimney sweep.
  • Professional installation is recommended for safety and functionality.
Safety
Modifications or non-approved accessories can compromise safety and functionality.
Assembly
  • Tools needed: Spirit level, Open-end spanner, Cutting nippers
  • Loose parts include gloves, seals, and screws.
  • Fresh air intake is crucial, especially in well-insulated homes.
Instructions for Use
  • Utilize CB-technology for clean burning.
  • Manage primary and secondary air for efficient combustion.
Instructions for Heating
  • Follow environmentally-friendly firing practices.
  • Be cautious of over-firing and adjust for weather conditions.
Handling of Fuel
  • Select appropriate wood and ensure it is properly stored and dried.
  • Illegal to use certain materials as fuel.
Maintenance
  • Regular chimney sweeping and stove cleaning are necessary.
  • Check and service the stove periodically.
Troubleshooting
Refer to the troubleshooting section for common issues and solutions.
Warranty
Details on warranty coverage and conditions are provided.
Conclusion
For best results, follow the top-down lighting method as described in the heating instructions.
Chimney Connection and Requirements
Guidance is provided for connecting a built-in stove to a steel chimney, emphasizing consultation with a Scan dealer or local chimney sweep. The chimney must have a T400 designation with G for the soot fire test, a minimum internal diameter of 148 mm, and a length of at least 4 meters.
Closed Combustion System
Recommended for airtight homes, involving external combustion air connection through a ventilation pipe.
Safety and Distance Requirements
Safety distances are outlined, with compliance to European, national, and local safety regulations mandatory.
Installation and Adjustment
Instructions for removing packaging and installing the stove are provided, including checking for damage and adjusting the stove's height.
Floor and Load-Bearing Requirements
The stove can be placed on ordinary beams or floors without reinforcement, with a floor plate necessary for flammable floors.
Instructions for Use
Features CB technology for optimal combustion, with specific air supply adjustments for normal load.
Instructions for Heating
Environmentally-friendly firing practices are emphasized, with specific instructions for top-down lighting and continuous operation.
Over-Firing Warning
Avoid excessive wood or air to prevent damage.
Weather Conditions
Adjust airflow based on weather to maintain good combustion.
Chimney Function
Ensure the chimney reaches operating temperature quickly.
Chimney Fire
In case of a chimney fire, keep all stove openings closed and contact emergency services.
General Notes
Exercise caution with hot surfaces and check for blockages before relighting.
Wood Selection and Handling
Use dry wood with a moisture content of 15-18% for best efficiency.
Maintenance
Regularly sweep the chimney and clean the stove, checking for cracks and replacing worn gaskets.
Cleaning and Disposal
Clean glass with appropriate cleaners and dispose of stove parts according to material type.
Troubleshooting
Address issues like smoke escaping and soot buildup by checking wood quality and airflow settings.
Stove Usage and Maintenance
Initial use may cause an odor due to lacquer hardening, and clicking noises are normal.
Warranty Information
Scan products come with a 5-year warranty covering manufacturing errors or defects, with specific exclusions.
Warranty Exclusions
The warranty is void in cases of incorrect installation, improper use, and unauthorized repairs.
Recommendations
Use original or manufacturer-recommended replacement parts to maintain warranty validity.
See more

Catalog excerpts

SCAN 41-1-1

EU - ASSEMBLY AND INSTRUCTIONS MANUAL ASSEMBLY AND INSTRUCTIONS MANUAL SCAN 41

 Open the catalog to page 1
SCAN 41-1-2

CONGRATULATIONS ON YOUR NEW SCAN WOOD-BURNING STOVE You have purchased a product by one of Europe’s leading manufacturers of wood-burning stoves, and we are sure that you will have years of pleasure from your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions. Read through this Assembly and Instruction Manual carefully before you start to assemble your stove.

 Open the catalog to page 2
SCAN 41-1-3

Technical data and dimensions 4 Dimension sketch and minimum distances 5 Product registration number ■ ASSEMBLY 10 Height adjustment of stove 11 Fitting the flue connection piece Tools needed for mounting of the stove Loose parts Additional accessories Closed combustion system Existing chimney and pre-fabricated element chimney Connection between built-in stove and steel chimney Requirements for chimney CB-technology (Clean Burn) Environmentally-friendly firing Lighting Continuous operation Warning about over-firing Using your stove in various weather conditions 20 Firing in the spring or autumn...

 Open the catalog to page 3
SCAN 41-1-4

TECHNICAL DATA INSTALLATION ¬ The house owner is responsible for ensuring that installation and assembly are in accordance with national and local building regulations as well as the information provided in this Assembly and Instruction Manual ¬ When you install any kind of fireplace or stove, you must inform the local building and housing authorities. In addition you are obliged to have the installation inspected and approved by a local chimney sweep prior to commissioning ¬ To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter. Your...

 Open the catalog to page 4
SCAN 41-1-5

Surface treatment Weight Scan 41-1 and Scan 41-2 Connecting piece internal diameter Connecting piece external diameter Approval type Steel plate Cast iron Galvanised sheet Vermicolite Scan 41-1 - Test in compliance with EN 13240 Scan 41-2 - Test in compliance with EN 13240 Intermittent operation in this context means normal use of a wood-burning stove. In other words, you should let the fire die down until only the embers are left before refueling. This stove is produced in accordance with type approval for the product, which also covers the product's Assembly and Instruction Manual. The Declaration...

 Open the catalog to page 5
SCAN 41-1-6

Flammable ceiling (All models) Opstillingstegning (afstand til brændbart materiale) Opstillingstegning (afstand til brændbart materiale) Radiation zone X / Y according to national laws and regulations Floor platee All distances are in mm. All distances are minimum distances * Connection of fresh-air intake Ø 100 mm ** Min. distance to furniture/flammable material *** Height to the beginning of flue connecting piece at top outlet Flammable material DIMENSION SKETCH AND MINIMUM D

 Open the catalog to page 6
SCAN 41-1-7

EMNE: Opstilling EMNE: Opstilling 50 mod brændbar væg, ovn uden sideruder MATERIALE: Minimum distance to flammable materials (with side windows) All distances are in mm. All distances are minimum distances * Half-insulated chimney / shielded flue pipe modin brændbar ovn uden sideruder NAVN:requirements EMNE: Scan 64 (The to the chimney andOpstilling the flue pipe terms ofvæg, safety distances must be met) Flammable material Minimum distance to flammable materials (without side windows)

 Open the catalog to page 7
SCAN 41-1-8

TG.NR: SIGN: Flammable material AREAL: 72301695 mm^2 DIMENSION: Krog Iversen & Co A/S Opstillingstegning (afstand til brandmur) Folder\Designs\Scan STI: C:\Working DK-5492 Vissenbjerg© All distances are in mm. DATO: 30-08-2022 SIGN: KEN VÆGT: 903,37 kg MATERIALE: DATO: 30-08-2022 SIGN: KEN VÆGT: 903,37 kg All distances are minimum distances AREAL: 72301695 mm^2 DIMENSION: Krog Iversen & Co A/S AREAL: flue 72301695 mm^2 * Half-insulated chimney / shielded pipe (The requirements to the&chimney Krog Iversen Co A/S and the flue pipe in terms of safety distances must be met) Opstillingstegning (afstand...

 Open the catalog to page 8
SCAN 41-1-9

TYPE PLATE All Scan wood-burning stoves are fitted with a type plate that specifies the approval standards and the distance to flammable materials. The type plate is located at the rear of the stove. Type plate Scan 41-1 (without side windows) Typeskilt Scan 41-2 (without side windows) PRODUCT REGISTRATION NUMBER All Scan wood-burning stoves are provided with a product registration number. Please make a note of this number at the rear page of this manual; you will always need to quote it when contacting your dealer or Scan A/S. The product registration number is located at the rear of the stove....

 Open the catalog to page 9
SCAN 41-1-10

■ Spirit level ■ Open-end spanner The loose parts are located in the stove's ash drawer. ■ Glove ■ Seal for the connecting piece ■ 4 pcs. screws M5x12 mm for fastening the connecting piece ■ 1 pcs. screw M5x6 mm, must be placed for United Kingdom ■ Small shaped floor plate in glass or steel ■ Large shaped floor plate in glass or steel ■ Adjustment key for height adjustment Your Scan stove may come supplied with the following packaging: In a well-insulated house, the air used up by the burning process has to be replaced. This particularly applies to houses with mechanical ventilation. There are...

 Open the catalog to page 10
SCAN 41-1-11

CLOSED COMBUSTION SYSTEM You should use the closed combustion system for the wood-burning stove if you live in a newly-built, airtight home. External combustion air is connected through a ventilation pipe via the wall or floor. It must be possible to shut off the ventilation pipe with a valve, when the stove is not in use. Minimum Ø 100 mm ventilation pipe, maximum length: 6 metres with a maximum of one bend. We recommend smooth steel pipes. We recommend mounting a valve in the ventilation pipe in order to avoid condensate in the stove and the pipe system, when the stove is not in use. It can...

 Open the catalog to page 11
SCAN 41-1-12

DISTANCE TO FURNITURE Distance to furniture from glass: 1000 mm. You should however assess whether furniture or other items might become excessively dry due to being too close to the stove. SAFETY DISTANCE European, national and local regulations concerning safety distances for wood-burning stoves must be complied with. There are no demands concerning the distance to non-flammable materials, but we recommend a distance of 50 mm in order to facilitate the cleaning of the stove, the flue pipes and the chimney and to prevent possible damages to the wall.

 Open the catalog to page 12

All Scan A/S catalogs and technical brochures

  1. SCAN 68-10

    44  Pages

  2. SCAN 67 1300

    36  Pages

  3. SCAN 66-2

    40  Pages

  4. SCAN 66-1 WALL

    40  Pages

  5. SCAN 65-1

    36  Pages

  6. SCAN 5005 FRL

    36  Pages

  7. SCAN 5003 S FR

    40  Pages

  8. SCAN 5004 FL

    44  Pages

  9. SCAN 5003 FL

    36  Pages

  10. SCAN 1006 CS

    3  Pages

  11. SCAN 1003 CS

    44  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.