This manual provides essential instructions for the assembly and use of a wood-burning stove from a leading European manufacturer, ensuring optimal performance and safety.
Technical Data
  • Materials: Steel plate, Galvanised sheet, Ceramic stone/vermiculite, Chamotte, Robax glass.
  • Efficiency: 82% with an energy efficiency class of A+.
  • Nominal output: 6-7 kW.
  • Chimney temperature: 224-227°C.
  • Fuel: Wood, with a consumption rate of 1.9-2.2 kg/h.
Installation
  • Professional installation is recommended to comply with local regulations.
  • Inform local authorities and have the installation inspected by a chimney sweep.
  • Ensure the foundation can support the stove's weight and maintain specified safety distances from flammable materials.
Assembly
  • Tools required include a spirit level, screwdrivers, and a wall drill.
  • Loose parts include bricks, log guard, and connecting pieces.
  • Dispose of packaging materials responsibly.
Instructions for Use
  • Utilize CB-technology for clean burning.
  • Adjust primary and secondary air for optimal combustion.
Heating Instructions
  • Use environmentally friendly operation methods.
  • Avoid over-firing to prevent damage.
  • Adapt usage based on weather conditions.
Fuel Handling
  • Select appropriate wood and ensure it is properly stored and dried.
  • Illegal to use certain materials as fuel.
Maintenance
  • Regularly sweep the chimney and clean the stove.
  • Check and service the stove components as needed.
Troubleshooting and Warranty
  • Refer to the troubleshooting section for common issues.
  • Warranty details are provided for customer assurance.
Chimney and Stove Connection
Guidance is provided for connecting a stove to an existing or pre-fabricated chimney. Consultation with an authorized dealer or chimney sweep is recommended to ensure compliance with manufacturer instructions. The chimney must have a minimum diameter of 148 mm, be labeled T400 and G for soot testing, and have a minimum length of 4.5 meters. Using a curved elbow pipe is advised for better draught, and safety distances must be adhered to.
Storage and Safety
Flammable materials should be stored with caution, using delivered magnets as distance pieces. Safety distances as per European, national, and local regulations must be maintained, particularly a 1500 mm distance from furniture to the stove glass.
Operating Instructions
The stove door should be closed firmly, similar to a car door. The flue connection piece can be adjusted for top or rear outlet, and components are located in the stove’s combustion chamber.
Fresh Air Intake and Combustion
In well-insulated homes, ensuring a fresh air supply is crucial. Installation of external air supply systems is outlined, recommending a minimum Ø100 mm ventilation pipe with a maximum length of 6 meters. The closed combustion system is advised for airtight homes, with specific instructions for mounting external air supply through the bottom or rear of the cassette.
Wall-Hung Model Installation
Installation must comply with building regulations, ensuring the stove is mounted on a non-flammable wall. The chimney must be self-supporting and not rest on the stove. Consultation with a building expert is advised for planning and approval.
Chimney and Draught Management
To ensure optimal draught, the chimney must reach operating temperature quickly, especially in poor weather conditions. Use thin wood and fire lighters to achieve this. Regularly check for blockages, especially after long periods of non-use. Multiple units can connect to one chimney, but regulations must be checked.
Chimney Fire Protocol
In case of a chimney fire, keep all stove openings closed and contact emergency services. A chimney sweep should inspect the chimney before reuse.
Wood Selection and Handling
Different woods have varying calorific values. Beech and oak have high values, requiring less fuel. Wood should be dry, with moisture content between 15-18% for efficiency. Illegal fuels include painted or treated wood, chipboard, and plastics.
Maintenance and Cleaning
Regular sweeping and cleaning are essential. Check for cracks and ensure gaskets are intact. Service the stove every two years using original parts. Clean glass with appropriate cleaners, avoiding contact with gaskets and painted surfaces.
Troubleshooting
Common issues include smoke escaping, rapid wood burning, and soot build-up. Causes range from damp wood to incorrect air settings. Ensure proper chimney draught and use dry wood.
Warranty Information
A 5-year warranty covers manufacturing defects but excludes wear and tear parts. The warranty is void in cases of incorrect installation, improper use, or unauthorized repairs.
See more

Catalog excerpts

SCAN 1006 BOX WALL VE-1

EU - ASSEMBLY AND INSTRUCTIONS MANUAL ASSEMBLY AND INSTRUCTION MANUAL SCAN 1006-B

 Open the catalog to page 1
SCAN 1006 BOX WALL VE-2

CONGRATULATIONS ON YOUR NEW SCAN WOOD-BURNING STOVE You have purchased a product by one of Europe’s leading manufacturers of wood-burning stoves, and we are sure that you will have years of pleasure from your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions. Read through this Assembly and Instruction Manual carefully before you start to assemble your stove.

 Open the catalog to page 2
SCAN 1006 BOX WALL VE-3

4 Dimension sketch and minimum distances Technical data and dimensions Tools needed for mounting of the stove Loose parts Disposal of packaging Additional accessories Load-bearing foundation Floor plate Existing chimney and pre-fabricated element chimney Connection between stove and steel chimney Storage of flammable material Carrying capacity Safety distance CB-technology (Clean Burn) Baffle plate Environmentally friendly operation Lighting Continuous operation Warning about over-firing Using the stove in various weather conditions 9 Fitting the flue connection piece 10 Closed combustion system...

 Open the catalog to page 3
SCAN 1006 BOX WALL VE-4

TECHNICAL DATA INSTALLATION o ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter. Your Scan T Dealer will be able to recommend a qualified fitter in your area. For information on Scan Dealers, please go to www.scan-stoves.com. ¬ The house owner is responsible for ensuring that installation and assembly are in accordance with national and local building regulations as well as the information provided in this Assembly and Instruction Manual ¬ When you install any kind of fireplace or stove, you must inform the local building and housing...

 Open the catalog to page 4
SCAN 1006 BOX WALL VE-5

Steel plate Galvanised sheet Ceramic stone/vermiculite Chamotte Robax glass Surface treatment Max. wood length Scan 1006-B Weight Scan 1006-B (Ceramic stone) ca. 163 kg * Intermittent operation in this context means normal use of a wood-burning stove. In other words, you should let the fire die down until only the embers are left before refuelling. Scan 1006-B is produced in accordance with type approval for the product, which also covers the product's Assembly and Instruction Manual. The Declaration of Performance (DoP) is available from www.scan.dk Weight Scan 1006-B (Vermiculite) Connecting...

 Open the catalog to page 5
SCAN 1006 BOX WALL VE-6

Målskitseto - væghængt til brændbart) X /EMNE: Y according national(afstand laws and regulations Radiation zone Målskitse - væghængt (afstand til brændbart) MATERIALE: Scan Combustibile floor Floor plate 91006005 DATO: 17-06-2020 SIGN: NAVN: Scan 1003-B Målskitse Scan 1006-B med sokkel Scan 1006-B with plinth Fire wall, e.g. 50 mm Jøtul Firewall, 110 mm brick or other material with corresponding fireproof and insulating abilities Flammable material All distances are in mm. All distances are minimum distances * Connection of fresh-air intake Ø 100 mm ** Min. distance to furniture/flammable material...

 Open the catalog to page 6
SCAN 1006 BOX WALL VE-7

Afstand til brændbar væg beskyttet af brandmur Minimum distance to flammable wall protected by a fire wall All distances are in mm. All distances are minimum distances * Half-insulated chimney (The requirements to the chimney and the flue pipe in terms of safety distances must be met) 0 Afstand til brændbart materiale, vist med uisoleret røgrør Fire wall, e.g. 50 mm Jøtul Firewall, 110 mm brick MATERIALE: or other material with corresponding fireproof and AREAL: DIMENSION: insulating abilities Flammable material Minimum distance to flammable materials

 Open the catalog to page 7
SCAN 1006 BOX WALL VE-8

TYPE PLATE All Scan wood burning stoves are fitted with a type plate that specifies the approval standards and the distance to flammable materials. The type plate (Vermiculite) is placed loose in the fireplace. It must be placed in a visible place on the stove. The eco energy label and type plate (Ceramic stone) are in the box with the ceramic stones and must replace the existing labels. Type plate Scan 1006-B (Ceramic stone) Type plate Scan 1006-B (Vermiculite) PRODUCT REGISTRATIONUMBER All Scan wood burning stoves are provided with a product registration number. Please make a note of this number...

 Open the catalog to page 8
SCAN 1006 BOX WALL VE-9

■ Spirit level ■ Cross tip screwdriver ■ Flat head screwdriver ■ 010 mm wall drill ■ Screws for connecting piece 5 x 12 mm ■ Screws for connecting piece/fresh air 4,2 x 6,5 mm ■ Screw M5x6 (Only used in Norway) ■ Burn chamber plates (side and rear) ■ Bricks for the bottom of the burn chamber ■ Gasket for connecting piece ■ Connecting piece for fresh air inlet ■ Decor ring for top outlet Your Scan stove may come supplied with the following packaging:

 Open the catalog to page 9
SCAN 1006 BOX WALL VE-10

ADDITIONAL ACCESSORIES ¬ Large module ¬ Large/small side module ¬ Large/small plinth for side module ¬ Large/small wall bracket ¬ Cover for fresh air inlet ¬ Small floor plate (glass or steel) ¬ Large floor plate (glass or steel) Small wall bracket Large wall bracket Large side module vægbeslag løse with fresh air inlet and heat 91010034 shield Small side module

 Open the catalog to page 10
SCAN 1006 BOX WALL VE-11

LOAD-BEARING FOUNDATION All items in our product range come under the category of lightweight fireplaces and stoves and do not normally require any reinforcement of the beam structure. They can be positioned on ordinary beams/floor. You should of course make sure that the foundation on which the stove is positioned can indeed support the weight of the stove and, where applicable, a steel chimney, if you have opted for this solution. In case of doubt about the carrying capacity of the floor, please consult a building expert. FLOOR PLATE If you are placing the stove on a flammable floor, you must...

 Open the catalog to page 11
SCAN 1006 BOX WALL VE-12

STORAGE OF FLAMMABLE MATERIAL ATTENTION!! It is important to use the delivered magnets as distance pieces between the modules when using these in connection with flammable materials. You can store wood under the stove in the module with heat shield and fresh air inlet CARRYING CAPACITY EMNE: assembly

 Open the catalog to page 12
SCAN 1006 BOX WALL VE-13

SAFETY DISTANCE European, national and local regulations concerning safety distances for wood-burning stoves and flue pipes must be complied with. If you connect the stove to a steel chimney, the safety distances of the steel chimney must also be respected. DISTANCE TO FURNITURE Distance to furniture from glass: 1500 mm. You should however assess whether furniture or other items might become excessively dry due to being too close to the stove. The wood-burning stove must be set up so that the stove itself, the flue pipe, and the chimney can all be cleaned. Målskitse Scan 1003-B VÆGT: N/A TG.NR:...

 Open the catalog to page 13

All Scan A/S catalogs and technical brochures

  1. SCAN 68-10

    44  Pages

  2. SCAN 67 1300

    36  Pages

  3. SCAN 66-2

    40  Pages

  4. SCAN 66-1 WALL

    40  Pages

  5. SCAN 65-1

    36  Pages

  6. SCAN 5005 FRL

    36  Pages

  7. SCAN 5003 S FR

    40  Pages

  8. SCAN 5004 FL

    44  Pages

  9. SCAN 5003 FL

    36  Pages

  10. SCAN 1006 CS

    3  Pages

  11. SCAN 41-1

    32  Pages

  12. SCAN 1003 CS

    44  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.