1. Catalogs
  2. Scan A/S
  3. SCAN 1005 BOX VE

SCAN 1005 BOX VE

SCAN 1005 BOX VE
1 / 36 PagesView full catalog

SCAN 1005 BOX VE

Product catalog summary
Introduction
This manual provides essential instructions for the assembly and use of a wood-burning stove, ensuring optimal performance and safety.
Technical Data
  • Materials: Steel plate, Galvanised sheet, Ceramic stone/vermiculite, Chamotte, Robax glass.
  • Efficiency: 82-84%, Energy efficiency class A+.
  • Nominal output: 6 kW.
  • Chimney temperature: 202-227°C.
  • Fuel: Wood, consumption rate of 1.8-1.9 kg/h.
Installation
  • Professional installation recommended to comply with regulations.
  • Inform local authorities and have installation inspected.
  • Ensure foundation supports stove weight and maintain safety distances from flammable materials.
Assembly
  • Tools required: Spirit level, screwdrivers, wall drill.
  • Loose parts include bricks, log guard, and connecting pieces.
  • Dispose of packaging materials responsibly.
Instructions for Use
  • Utilize CB-technology for clean burning.
  • Adjust primary and secondary air for optimal combustion.
Heating Instructions
  • Follow environmentally friendly operation guidelines.
  • Use top-down lighting method.
  • Avoid over-firing to prevent damage.
Fuel Handling
  • Select wood with low moisture content.
  • Illegal to use certain materials as fuel.
Maintenance
  • Regularly sweep chimney and clean stove.
  • Check and service stove periodically.
  • Replace gaskets and clean glass as needed.
Troubleshooting
Refer to the troubleshooting section for common issues and solutions.
Warranty
Details on warranty coverage are provided.
Conclusion
Adhere to guidelines for optimal use and safety. Contact your dealer for further assistance if needed.
Chimney Connection and Requirements
Consult an authorized dealer or chimney sweep for guidance on chimney connection. Ensure compatibility with stove and follow manufacturer instructions for pre-fabricated chimneys. Minimum chimney diameter is 148 mm, labeled T400 and G for soot testing, with a minimum length of 4.5 meters.
Safety and Installation Distances
Compliance with regulations regarding safety distances is mandatory. Distance to furniture from stove's glass should be at least 1500 mm. Ensure accessibility for cleaning.
Operating the Stove
Ensure stove door is closed firmly. The stove is prepared for a top flue outlet, with adjustable connection for a rear outlet.
Fresh Air Intake and Closed Combustion System
Ensure a supply of fresh air in well-insulated homes. For airtight homes, use a closed combustion system with external air connected through a ventilation pipe.
Mounting Instructions
For wall-hung models, ensure wall is non-flammable and has sufficient load-bearing capacity. Use supplied wall brackets for installation.
Installation and Assembly Instructions
  • Module Assembly: Fit connecting piece with gasket and screws. Mount fittings on other modules.
  • Heat Shield and Type Plate: Adjust stove using adjustment screw. Ensure correct type plate placement.
  • Wall Bracket Mounting: Use spirit level for adjustments.
Combustion Chamber Installation
  • Handling Baffle Plates: Handle with care to avoid breakage.
  • Mounting Instructions: Follow steps for mounting burn chamber and baffle plates.
Door Adjustment
  • Adjusting the Door: Use tools to adjust door position and spring tension.
Usage Instructions
  • CB-Technology: Directs heated air for optimal combustion.
  • Air Control: Adjust primary and secondary air for efficient operation.
  • Environmentally Friendly Operation: Avoid low flame operation.
  • Continuous Operation: Maintain high temperatures for efficiency.
  • Weather Conditions: Adjust airflow based on conditions.
General Notes
  • Exercise caution as stove surfaces become hot. Avoid placing flammable materials near the stove.
Chimney Function
  • Ensure proper chimney draught for efficient operation.
Chimney and Draught Management
Ensure chimney reaches operating temperature quickly. Check for blockages after non-use and consult regulations for multiple units.
Wood Selection and Handling
Use wood with moisture content of 15-18%. Avoid illegal fuels.
Maintenance
Regular cleaning and inspection are essential. Service stove every two years.
Troubleshooting
Common issues include smoke escaping and soot build-up. Adjust air valves and ensure proper chimney draught.
Warranty
5-year warranty covers manufacturing defects, excluding wear and tear and improper use.
See more

Catalog excerpts

SCAN 1005 BOX VE-1

EU - ASSEMBLY AND INSTRUCTIONS MANUAL ASSEMBLY AND INSTRUCTION MANUAL SCAN 1005-B

 Open the catalog to page 1
SCAN 1005 BOX VE-2

CONGRATULATIONS ON YOUR NEW SCAN WOOD-BURNING STOVE You have purchased a product by one of Europe’s leading manufacturers of wood-burning stoves, and we are sure that you will have years of pleasure from your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions. Read through this Assembly and Instruction Manual carefully before you start to assemble your stove.

 Open the catalog to page 2
SCAN 1005 BOX VE-3

4 Dimension sketch and minimum distances Technical data and dimensions Tools needed for mounting of the stove Loose parts Disposal of packaging Additional accessories Load-bearing foundation Floor plate Existing chimney and pre-fabricated element chimney Connection between stove and steel chimney Storage of flammable material Carrying capacity Safety distance CB-technology (Clean Burn) Baffle plate Environmentally friendly operation Lighting Continuous operation Warning about over-firing Using the stove in various weather conditions 9 Fitting the flue connection piece 10 Closed combustion system...

 Open the catalog to page 3
SCAN 1005 BOX VE-4

TECHNICAL DATA INSTALLATION o ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter. Your Scan T Dealer will be able to recommend a qualified fitter in your area. For information on Scan Dealers, please go to www.scan-stoves.com. ¬ The house owner is responsible for ensuring that installation and assembly are in accordance with national and local building regulations as well as the information provided in this Assembly and Instruction Manual ¬ When you install any kind of fireplace or stove, you must inform the local building and housing...

 Open the catalog to page 4
SCAN 1005 BOX VE-5

Steel plate Galvanised sheet Ceramic stone/vermiculite Chamotte Robax glass Surface treatment Max. wood length Scan 1005-B Weight Scan 1005-B (Ceramic stone) ca. 140 kg * Intermittent operation in this context means normal use of a wood-burning stove. In other words, you should let the fire die down until only the embers are left before refuelling. Scan 1005-B is produced in accordance with type approval for the product, which also covers the product's Assembly and Instruction Manual. The Declaration of Performance (DoP) is available from www.scan-stoves.com Weight Scan 1005-B (Vermiculite) Connecting...

 Open the catalog to page 5
SCAN 1005 BOX VE-6

All distances are in mm. All distances are minimum distances * Connection of fresh-air intake Ø 100 mm ** Min. distance to furniture/flammable material *** Height to the beginning of flue connecting piece at top outlet Fire wall, e.g. 50 mm Jøtul Firewall, 110 mm brick or other material with corresponding fireproof and insulating abilities Flammable material Målskitseto - væghængt til brændbart) X /EMNE: Y according national(afstand laws and regulations Radiation zone 93 Målskitse - væghængt (afstand til brændbart) Combustibile floor Floor plate Målskitse Scan 1005-B med sokkel Scan 1005-B with...

 Open the catalog to page 6
SCAN 1005 BOX VE-7

Afstand til brændbar væg beskyttet af brandmur Minimum distance to flammable wall protected by a fire wall All distances are in mm. All distances are minimum distances * Half-insulated chimney (The requirements to the chimney and the flue pipe in terms of safety distances must be met) 0 Afstand til brændbart materiale, vist med uisoleret røgrør Fire wall, e.g. 50 mm Jøtul Firewall, 110 mm brick MATERIALE: or other material with corresponding fireproof and AREAL: DIMENSION: insulating abilities Flammable material Minimum distance to flammable materials

 Open the catalog to page 7
SCAN 1005 BOX VE-8

TYPE PLATE All Scan wood burning stoves are fitted with a type plate that specifies the approval standards and the distance to flammable materials. The type plate (Vermiculite) is placed loose in the fireplace. It must be placed in a visible place on the stove. The eco energy label and type plate (Ceramic stone) are in the box with the ceramic stones and must replace the existing labels. Type plate Scan 1005-B (Ceramic stone) Type plate Scan 1005-B (Vermiculite) PRODUCT REGISTRATIONUMBER All Scan wood burning stoves are provided with a product registration number. Please make a note of this number...

 Open the catalog to page 8
SCAN 1005 BOX VE-9

■ Spirit level ■ Cross tip screwdriver ■ Flat head screwdriver ■ 010 mm wall drill ■ Screws for connecting piece 5 x 12 mm ■ Screws for connecting piece/fresh air 4,2 x 6,5 mm ■ Screw M5x6 (Only used in Norway) ■ Burn chamber plates (side and rear) ■ Bricks for the bottom of the burn chamber ■ Gasket for connecting piece ■ Connecting piece for fresh air inlet ■ Decor ring for top outlet Your Scan stove may come supplied with the following packaging:

 Open the catalog to page 9
SCAN 1005 BOX VE-10

ADDITIONAL ACCESSORIES ¬ Large/small module ¬ Large/small wall bracket ¬ Cover for fresh air inlet ¬ Small floor plate (glass or steel) ¬ Large floor plate (glass or steel) Small wall bracket Large wall bracket Large module 0 20 Large module with fresh air inlet and heat shield - is not to be used under the stove! vægbeslag løse Krog Iversen & Co A/S DK-5492 Vissenbjerg© Small module Large plinth

 Open the catalog to page 10
SCAN 1005 BOX VE-11

LOAD-BEARING FOUNDATION All items in our product range come under the category of lightweight fireplaces and stoves and do not normally require any reinforcement of the beam structure. They can be positioned on ordinary beams/floor. You should of course make sure that the foundation on which the stove is positioned can indeed support the weight of the stove and, where applicable, a steel chimney, if you have opted for this solution. In case of doubt about the carrying capacity of the floor, please consult a building expert. FLOOR PLATE If you are placing the stove on a flammable floor, you must...

 Open the catalog to page 11
SCAN 1005 BOX VE-12

STORAGE OF FLAMMABLE MATERIAL ATTENTION!! It is important to use the delivered magnets as distance pieces between the modules when using these in connection with flammable materials. You can store wood under the stove in the module with heat shield and fresh air inlet CARRYING CAPACITY EMNE: assembly

 Open the catalog to page 12

All Scan A/S catalogs and technical brochures

  1. SCAN 68-10

    44  Pages

  2. SCAN 67 1300

    36  Pages

  3. SCAN 66-2

    40  Pages

  4. SCAN 66-1 WALL

    40  Pages

  5. SCAN 65-1

    36  Pages

  6. SCAN 5005 FRL

    36  Pages

  7. SCAN 5003 S FR

    40  Pages

  8. SCAN 5004 FL

    44  Pages

  9. SCAN 5003 FL

    36  Pages

  10. SCAN 1006 CS

    3  Pages

  11. SCAN 41-1

    32  Pages

  12. SCAN 1003 CS

    44  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.