1. Catalogs
  2. Scan A/S
  3. SCAN 1003 BOX CS

SCAN 1003 BOX CS
1 /36Pages

SCAN 1003 BOX CS

SCAN 1003 BOX CS
1 /36Pages

Catalog excerpts

SCAN 1003 BOX CS-1

UK - ASSEMBLY AND INSTRUCTIONS MANUAL ASSEMBLY AND INSTRUCTION MANUAL SCAN 1003-B

 Open the catalog to page 1
SCAN 1003 BOX CS-2

CONGRATULATIONS ON YOUR NEW SCAN WOOD-BURNING STOVE You have purchased a product by one of Europe’s leading manufacturers of wood-burning stoves, and we are sure that you will have years of pleasure from your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions. Read through this Assembly and Instruction Manual carefully before you start to assemble your stove.

 Open the catalog to page 2
SCAN 1003 BOX CS-3

Technical data and dimensions 5 Dimension sketch and minimum distances 6 Tools needed for mounting of the stove Loose parts Disposal of packaging Additional accessories Load-bearing foundation Floor plate Existing chimney and pre-fabricated element chimney Connection between stove and steel chimney Storage of flammable material Carrying capacity Safety distance CB-technology (Clean Burn) Baffle plate Environmentally friendly operation Lighting Continuous operation Warning about over-firing Using the stove in various weather conditions 9 Fitting the flue connection piece 10 Closed combustion system...

 Open the catalog to page 3
SCAN 1003 BOX CS-4

TECHNICAL DATA INSTALLATION ¬ The house owner is responsible for ensuring that installation and assembly are in accordance with national and local building regulations as well as the information provided in this Assembly and Instructions Manual ¬ When you install any kind of fireplace or stove, you must inform the local building and housing authorities. In addition you are obliged to have the installation inspected and approved by a local chimney sweep prior to commissioning ¬ To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter....

 Open the catalog to page 4
SCAN 1003 BOX CS-5

Steel plate Galvanised sheet Ceramic stone/vermiculite Chamotte Robax glass Surface treatment Max. wood length Scan 1003-B Weight Scan 1003-B (Vermiculite) ca. 137 kg * Intermittent operation in this context means normal use of a wood-burning stove. In other words, you should let the fire die down until only the embers are left before refuelling. Scan 1003-B is produced in accordance with type approval for the product, which also covers the product's Assembly and Instruction Manual. The Declaration of Performance (DoP) is available from www.scan-stoves.com Connecting piece internal diameter 144...

 Open the catalog to page 5
SCAN 1003 BOX CS-6

All distances are in mm. All distances are minimum distances * Connection of fresh-air intake Ø 100 mm ** Min. distance to furniture/flammable material *** Height to the beginning of flue connecting piece at top outlet Fire wall, e.g. 50 mm Jøtul Firewall, 110 mm brick or other material with corresponding fireproof and insulating abilities Flammable material Målskitseto - væghængt til brændbart) X /EMNE: Y according national(afstand laws and regulations Radiation zone Målskitse - væghængt (afstand til brændbart) Combustibile floor Floor plate Målskitse Scan 1003-B med sokkel Scan 1003-B with...

 Open the catalog to page 6
SCAN 1003 BOX CS-7

Afstand til brændbar væg beskyttet af brandmur Minimum distance to flammable wall protected by a fire wall All distances are in mm. All distances are minimum distances * Half-insulated chimney (The requirements to the chimney and the flue pipe in terms of safety distances must be met) 0 Afstand til brændbart materiale, vist med uisoleret røgrør Fire wall, e.g. 50 mm Jøtul Firewall, 110 mm brick MATERIALE: or other material with corresponding fireproof and AREAL: DIMENSION: insulating abilities Flammable material Minimum distance to flammable materials

 Open the catalog to page 7
SCAN 1003 BOX CS-8

TYPE PLATE All Scan wood burning stoves are fitted with a type plate that specifies the approval standards and the distance to flammable materials. The type plate (Vermiculite) is placed loose in the fireplace. It must be placed in a visible place on the stove. The type plate for UK must be stuck on top of the existing type plate. Please do not cover the product registration number. Type plate Scan 1003-B for UK Type plate Scan 1003-B (Vermiculite) PRODUCT REGISTRATIONUMBER All Scan wood burning stoves are provided with a product registration number. Please make a note of this number at the rear...

 Open the catalog to page 8
SCAN 1003 BOX CS-9

■ Spirit level ■ Cross tip screwdriver ■ Flat head screwdriver ■ 010 mm wall drill ■ Combo wrench 8 mm ■ 2 allen keys (2,5 mm & 5 mm) The trim and burn chamber plates (side and rear) are packed separately. In the stoves combustion chamber you will find the following loose parts: ■ Glove ■ Connecting pieces 0144/148 mm ■ Bag containing loose parts: 0100 mm sleeve with flange 4 x Allen screws M4x10 mm 8 x 3 mm black self-adhesive gasket (2 m) 4 x flange nuts M5 (0100 mm sleeve, connecting piece and cassette) (for fastening the connecting piece) 3 x pins 06 x 50 mm (for baffles plates) Decor ring...

 Open the catalog to page 9
SCAN 1003 BOX CS-10

ADDITIONAL ACCESSORIES ¬ Large/small module ¬ Large/small wall bracket ¬ Cover for fresh air inlet ¬ Small floor plate (glass or steel) ¬ Large floor plate (glass or steel) Small wall bracket Large wall bracket Large module Large module vægbeslag løse Krog Iversen & Co A/S DK-5492 Vissenbjerg© Small module Large plinth - is not to be 91010034 used directly under the stove! with fresh air inlet and heat shield

 Open the catalog to page 10
SCAN 1003 BOX CS-11

LOAD-BEARING FOUNDATION All items in our product range come under the category of lightweight fireplaces and stoves and do not normally require any reinforcement of the beam structure. They can be positioned on ordinary beams/floor. You should of course make sure that the foundation on which the stove is positioned can indeed support the weight of the stove and, where applicable, a steel chimney, if you have opted for this solution. In case of doubt about the carrying capacity of the floor, please consult a building expert. FLOOR PLATE If you are placing the stove on a flammable floor, you must...

 Open the catalog to page 11
SCAN 1003 BOX CS-12

STORAGE OF FLAMMABLE MATERIAL ATTENTION!! It is important to use the delivered magnets as distance pieces between the modules when using these in connection with flammable materials. You can store wood under the stove in the module with heat shield and fresh air inlet CARRYING CAPACITY EMNE: assembly

 Open the catalog to page 12

All Scan A/S catalogs and technical brochures

  1. SCAN 68-10

    44  Pages

  2. SCAN 67 1300

    36  Pages

  3. SCAN 66-2

    40  Pages

  4. SCAN 66-1 WALL

    40  Pages

  5. SCAN 65-1

    36  Pages

  6. SCAN 5005 FRL

    36  Pages

  7. SCAN 5003 S FR

    40  Pages

  8. SCAN 5004 FL

    44  Pages

  9. SCAN 5003 FL

    36  Pages

  10. SCAN 1006 CS

    3  Pages

  11. SCAN 41-1

    32  Pages

  12. SCAN 1003 CS

    44  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.