REGULATION REGULATION VARIABLE FLOW VARIABLE FLOW RPM-V - RPMC-V SERIES RPM-V RPMC-V Air flow regulator, with variable flow. Circular Air flow regulator, with variable flow. S
Open the catalog to page 1REGULATION VARIABLE FLOW
Open the catalog to page 2VARIABLE FLOW DAMPER Model RPM-V. The air volume controllers are meant for systems with a variable air volume that is used for input or output air. The required amount of air that is taken into the individual rooms or working areas is variable with respect to time and can be changed according to momentary need when the controllers are installed. Total power of air-conditioning system can be lower. This variable systems enable a more economical operation air-conditioning systems and while ensuring individual well-being on the premises setting. The controller consists of the body of the...
Open the catalog to page 3VARIABLE FLOW DAMPER RPM-V 1. Regulator body 2. Controller 3. Controller blade 4. Tab 5. Pressure sampling -p1 6. Pressure sampling -p2 7. Rubber seal RPM-V Air flow control Pressure sensors 5 Muestreo de presión - p1 RPM-V Hoja del controlador 6 Pipe pressureMuestreo de presión - p2 control RPM-V Room pressure control Actuating mechanism Pressure controller Actuating mechanism Pressure controller Static pressure sensor Actuating mechanism Static pressure sensor ∆ρ [Рa] Controller pressure loss RPM-V Recommmended distance from double branch joint ∆ρs [Рa] Static pressure difference between...
Open the catalog to page 4SERIES TECHNICAL DATA Air volume Air volume [m³/h] Dimensions AxB [mm] Standard values* Maximum values REGULATION VARIABLE FLOW *Default controller settings
Open the catalog to page 5SERIES TECHNICAL DATA Determination of actual air volume Air volume value is determined by means of the computation from the measured value U5 Sample for the operating mode 2…10V Sample for the operating mode 0…10V Searched for : actual air volume Búsqueda para: volumen de aire efectivo Voltage measured on U Tensión medida en5 : 3,5 V V : 3,5 Vnom = 2800 m .h 2800 = 525 8 Actual air volume aire m³ h-1 El volumen de is 525actual es 525 m .h . Searched for : actual air volume Búsqueda para: volumen de aire efectivo Voltage measured on U5 : 3,5 V Actual air volume is 770 m³ h-1 El volumen de...
Open the catalog to page 6SERIES TECHNICAL DATA Sound power level inside the pipeline at pressure difference 50 Pa REGULATION VARIABLE FLOW
Open the catalog to page 7SERIES TECHNICAL DATA Sound power level inside the pipeline at pressure difference 100 Pa REGULATION VARIABLE FLOW
Open the catalog to page 8SERIES TECHNICAL DATA Sound power level inside the pipeline at pressure difference 250 Pa REGULATION VARIABLE FLOW
Open the catalog to page 9SERIES TECHNICAL DATA Sound power level inside the pipeline at pressure difference 500 Pa REGULATION VARIABLE FLOW
Open the catalog to page 10SERIES TECHNICAL DATA Sound power level Lwa [dB (A)] inside the pipeline REGULATION VARIABLE FLOW
Open the catalog to page 11SERIES TECHNICAL DATA Sound power level Lwa [dB (A)] inside the pipeline REGULATION VARIABLE FLOW
Open the catalog to page 12SERIES TECHNICAL DATA Sound power level Lwa [dB (A)] inside the pipeline REGULATION VARIABLE FLOW
Open the catalog to page 13SERIES TECHNICAL DATA Sound power level radiated outside the pipeline - without insulation The radiated noise of the air volume controller is given below V [m³h-1 ] - air flow volume ∆st [Pa] pressure differential REGULATION VARIABLE FLOW LWA [dB(A)] - otal level of acoustic power corrected by
Open the catalog to page 14SERIES TECHNICAL DATA Sound power level Lwa [dB(A)] radiated outside the pipeline, without insulation REGULATION VARIABLE FLOW
Open the catalog to page 15SERIES TECHNICAL DATA Sound power level Lwa [dB(A)] radiated outside the pipeline, without insulation
Open the catalog to page 16SERIES TECHNICAL DATA Sound power level Lwa [dB(A)] radiated outside the pipeline, without insulation REGULATION VARIABLE FLOW
Open the catalog to page 17VARIABLE FLOW DAMPER Model RPMC-V. The air volume controllers are meant for systems with a variable air volume that is used for input or output air. The required amount of air that is taken into the individual rooms or working areas is variable with respect to time and can be changed according to momentary need when the controllers are installed. Total power of air-conditioning system can be lower. This variable systems enable a more economical operation air-conditioning systems and while ensuring individual well-being on the premises setting. The controller consists of the body of the...
Open the catalog to page 18VARIABLE FLOW DAMPER Air Volume Air Volume [m³/h] Dimensions AxB [mm] Standard values* Minimal (w ≈ 1m/s) Maximum values Vnom REGULATION VARIABLE FLOW
Open the catalog to page 19SERIES TECHNICAL DATA Determination of actual air volume Air volume value is determined by means of the computation from the measured value U5 Sample for the operating mode 2…10V Searched for : actual air volume Búsqueda para: volumen de aire efectivo Voltage measured on U Tensión medida en5 : 3,5 V V : 3,5 Vnom = 2800 m .h Sample for the operating mode 0…10V 2800 = 525 8 Actual air volume aire m³ h-1 El volumen de is 525actual es 525 m .h . Searched for : actual air volume Búsqueda para: volumen de aire efectivo Voltage measured on U5 : 3,5 V Actual air volume is 770 m³ h-1 El volumen de...
Open the catalog to page 20SERIES TECHNICAL DATA Sound power level inside the pipeline at pressure difference 50 Pa REGULATION VARIABLE FLOW *Default controller settings
Open the catalog to page 21SERIES TECHNICAL DATA Sound power level inside the pipeline at pressure difference 50 Pa REGULATION VARIABLE FLOW
Open the catalog to page 22SERIES TECHNICAL DATA Sound power level inside the pipeline at pressure difference 50 Pa REGULATION VARIABLE FLOW *Default controller settings
Open the catalog to page 23SERIES TECHNICAL DATA Sound power level inside the pipeline at pressure difference 100 Pa REGULATION VARIABLE FLOW
Open the catalog to page 24SERIES TECHNICAL DATA Sound power level inside the pipeline at pressure difference 100 Pa REGULATION VARIABLE FLOW *Default controller settings
Open the catalog to page 25SERIES TECHNICAL DATA Sound power level inside the pipeline at pressure difference 100 Pa REGULATION VARIABLE FLOW
Open the catalog to page 26SERIES TECHNICAL DATA Sound power level inside the pipeline at pressure difference 250 Pa REGULATION VARIABLE FLOW
Open the catalog to page 27SERIES TECHNICAL DATA Sound power level inside the pipeline at pressure difference 250 Pa REGULATION VARIABLE FLOW