Emergency Lighting
12Pages

{{requestButtons}}

Catalog excerpts

Emergency Lighting - 1

ISSUE DE SI A «V utilizer qu‘ en cos cf urgcnce European area version

Open the catalog to page 1
Emergency Lighting - 2

Technical lighting expert, Sammode is also an active partner of industrials since 1927. Answering to high quality and technical standards, our luminaires are designed to be used in extreme conditions. We guarantee quality and performance ROBUST Resulting from our engineering expertise, our luminaires are designed to be shock resistant (IK10). The robustness of the housing, the quality of selected materials and components are a guarantee of long-term investment. The absolute imperviousness (IP68) of our light fittings reduces surface condensation or frost phenomena due to negative...

Open the catalog to page 2
Emergency Lighting - 3

SELECTION GUIDE Product SELF-CONTAINED VERSIONS Escape route lighting: autonomie 1 hour Escape route lighting: autonomie 3 hours CENTRAL BATTERY VERSIONS Escape route lighting Maxwell 100 LSO EVAO Open area lighting Maxwell 100 LSO AMB Open area and escape route lighting Maxwell 100 LSO BT Our Luminaires are compliant with the EN 60 598-1 and EN 60598-2-22 standards.

Open the catalog to page 3
Emergency Lighting - 4

Self-contained versions

Open the catalog to page 4
Emergency Lighting - 5

marque tridimensionnelle IAXWI ESCAPE ROUTE UGHTING IMPERVIOUS Tubular self-contained luminaire description EMERGENCY LIGHTING Escape route lighting Maintained and non-maintained Emergency output: 45 lm minimum Compliant with the standards: EN 60 598-1, EN 60598-2-22 Automatic tests compliant with IEC 62034 Addressable version (DALI) available Single sided signage TUBULAR Increased mechanical resistance Easy to clean Limited dirt accumulation 360° orientation HOUSING • 0100 mm satin-finish polycarbonate diffuser • End caps V2 ring press-formed in 304L stainless steel (316L also available) •...

Open the catalog to page 5
Emergency Lighting - 6

MAXWE ESCAPE ROUTE UGHTING IMPERVIOUS Tubular self-contained LUMINAIRE ELECTRICAL CLASS CLASS 1 MAIN REFERENCES EMERGENCY OUTPUT (lm) DESIGNATIONCODEWEIGHT (kg) Standard version 45 MAX100 S3H 45-865 SA 113LN 1841 0030 1,3 Please refer to the instruction sheets on our website for any information concerning the consumption. EMERGENCY LIGHTING Escape route lighting Maintained and non-maintained Emergency output: 45 lm minimum Compliant with the standards: EN 60 598-1, EN 60598-2-22 Automatic tests compliant with IEC 62034 Addressable version (DALI) available Single sided signage TUBULAR...

Open the catalog to page 6
Emergency Lighting - 7

Central battery versions

Open the catalog to page 7
Emergency Lighting - 8

ESCAPE ROUTE LIGHTING -20°C +40°C - 75LM - LED ESCAPE ROUTE UGHTING IMPERVIOUS Tubular UGHT FITTING FOR 230V AC/DC CENTRAL BATTERY SYSTEM DESCRIPTION OPTIONS OPTION CODE DESCRIPTION EMERGENCY LIGHTING Escape route lighting Maintained and non-maintained Emergency output: 75 lm Compliant with the standards: EN 60 598-1, EN 60598-2-22 Single sided signage TUBULAR Increased mechanical resistance Easy to clean Limited dirt accumulation 360° orientation IMPERVIOUS (IP68) Absolute imperviousness No internal dust accumulation Maximum light output Adapted for pressure cleaning limited MAINTENANCE...

Open the catalog to page 8
Emergency Lighting - 9

OPEN AREA LIGHTING -20°C +40°C - 330LM - LED OPEN AREA UGHTING IMPERVIOUS Tubular UGHT FITTING FOR 230V AC/DC CENTRAL BATTERY SYSTEM EMERGENCY LIGHTING Open area lighting Maintained and non-maintained Emergency output: 330 lm Compliant with the standards: EN 60 598-1, EN 60598-2-22 TUBULAR Increased mechanical resistance Easy to clean Limited dirt accumulation 360° orientation IMPERVIOUS (IP68) Absolute imperviousness No internal dust accumulation Maximum light output Adapted for pressure cleaning limited MAINTENANCE Led luminaire HOUSING • 0100 mm satin-finish polycarbonate diffuser • End...

Open the catalog to page 9
Emergency Lighting - 10

Central battery version for low temperature -60°C to +25°C

Open the catalog to page 10
Emergency Lighting - 11

24V DC - OPEN AREA AND ESCAPE ROUTE LIGHTING -60°C +25°C - 400LM - LED MAXWEI IMPERVIOUS TUBULAR SAFETY LIGHT FITTING FOR LOW-TEMPERATURE AND 24V DC CENTRAL BATTERY SYSTEM description HOUSING • 0100 mm satin-finish polycarbonate diffuser • End caps V2 ring press-formed in 304L stainless steel (316L also available) • Gaskets molded in EPDM • Cable entry with cable gland in nickelcoated brass (ext. 0 5-14mm) or with disconnectable plug (ext. 0 8-10 mm) GEAR TRAY • Black powder coated gear • Extreme cold electronic modules developed by SAMMODE equipped of EMERGENCY LIGHTING Open area lighting...

Open the catalog to page 11
Emergency Lighting - 12

We reserve the right to make technical changes • © Sammode - 03/2014 - european area version