Catalog excerpts

Solutions for Telecom network duct covers New ranges Telecom duct covers
Open the catalog to page 1
At the service of water and sewerage, PAM is worldwide leader in ductile iron pipeline systems. PAM proposes solutions dedicated to the water, sewage, roads, telecom and building sectors. Interface between the roadway and the networks, the municipal castings must meet the numerous performance and quality criteria set by the network managers in terms of: • resistance to traffic constraints: safety, stability, silence, • easy to access and operation: simple, fast and ergonomic handling, • quick and easy implementation: installation under all worksite conditions. A combination of performance...
Open the catalog to page 2
Ductile iron frame Built-in hinge Safety kits O pening assistance kit P 2 to 5 Steel angle bar frame 2 covers C250 Safety kits O pening assistance kit P 6 to 9 Steel angle bar frame 1 cover C250 or 1 cover B125 P 10 to 11
Open the catalog to page 3
Specialist in the design and distribution of innovating technical solutions in municipal castings, sewerage and Telecom, PAM proposes a range of intelligently designed duct covers which adapt to all your constraints, in respect of the environment. T-Max D400 duct cover has truly innovating features. Beneath the apparent simplicity lies an ingenious technology offering outstanding results in terms of durability (frame rigidity and sealing performance), adaptation to requirements that change over time, but also in terms of easy installation and, if necessary, intervention (optimum safety and...
Open the catalog to page 4
ASSISTANCE OR SAFETY KITS Intelligent hinge with numerous advantages 1 Built into the basic version, the internal hinge allows the hinged cover to be lifted in the traditional manner by 2 operators 2 However, due to its low weight (< 45 kg) and safety blocking, the cover can now be open by a single maintenance operator. The lifting force is less than16 kg. Convert the duct covers on your site yourself. • he additional functions offered by the kits T must be mounted after installation of the duct covers. • he kits mounting is done with a limited T number of tools and the structure requires...
Open the catalog to page 5
Ductile iron frame: 80 mm T profile + studs for improved sealing (total height 120 mm). Built-in hinge to retain traditional horizontal lifting and hinge with 90° safety blocking. Safety or assistance kits (gas arm): - to be installed on site after the duct covers embedment - the structure requires no preparation - installed with a limited number of tools - supplied with installation instructions - animated videos on www.pamline.fr
Open the catalog to page 6
T-MAX i D400 duct covers with ductile iron covers and frames (1) If assistance is required for all covers, order 2 kits for a K2C and 3 for a K3C (2) Other locks be developed for special work sites or specific operators Advantages of the PAM offer Safety and assistance are provided by kits to be installed on site. Since the covers are interchangeable, the master cover can be positioned as required. With the oscillating fastener, when the cover is open the gas arm is not under tension and can therefore be removed easily.
Open the catalog to page 7
[Tnew range “1 1 developed from a known, high-potential traditional I CONCEPT | The class C 250 duct covers are a generic product with a wide range of applications. On pavements, they are preferred to the traditional sewage manhole covers due to their wide free opening allowing easy intervention on the underground equipment. Applications for example, urban heating, and wiring, etc. Using traditional but optimised components, with the T-Max i C250 range, PAM offers innovating solutions which are especially intended for current market requirements : - cost-effective solutions - modular on...
Open the catalog to page 8
KITS TO BE INSTALLED ON SITE BEFORE SEALING THE HATCH Innovating solutions applied to standard components 1 Soundproofing pads inserted in the factory under the prising slots, limited deformation and therefore increased durability The kits are installed with a limited number of tools and require only minor changes of the chamber: Clearance under the frame for insertion of the lock back > he kits are supplied with t installation instructions 2 Cover optimisation C 250 - 633 x 495 mm 26 kg instead of 36 kg C 250 - 990 x 633 mm 61 kg instead of 80 kg Covers interchangeable with old generation...
Open the catalog to page 9
Special frames: galvanised steel angle bars 60 x 60 x 6 mm with 2 holes per cover to install the kits. Ductile iron covers: • Optimised • Equipped with ergonomic handling boxes, compatible with plate hammers • Soundproofing pads under the handling boxes, limited deformation and therefore increased durability
Open the catalog to page 10
T-MAX i C250 duct covers with ductile iron covers 633 x 495 mm Advantages of the PAM offer • Cost-effective development of the T-Max i D 400 concept for C 250 duct covers • Just 4 kits for the entire range • Possibility of choosing on site the position of the duct covers to be equipped with additional functions (no delay to procure specific reference) • Covers interchangeable with old generation covers
Open the catalog to page 11
New optimised duct covers to close standardised chambers LOT to L4T Angle bar frame: galvanised steel 50 x 30 x 5 mm. B125 cover for L0T C250 cover for LIT to L4T Registered models
Open the catalog to page 12
Other logos or specific marking: please contact us Advantages of the PAM offer Despite being lightweight, the covers can withstand accidental traffic. The ductile iron feet of the covers are protected by soundproofing pads: - efficient attachment of the pad, - effective soundproofing.
Open the catalog to page 13
Telecom duct covers with ductile iron covers on galvanised steel frame Reference with Telecom logo Ductile iron covers only C250 and B125 for galvanised steel frame Plate hammers Telecom Europe duct covers with hinged triangular covers on ductile iron frame * Duct covers equipped with an SCS lock
Open the catalog to page 14
Sealing of access duct covers to Telecom Networks Design of concrete chamber top Most of the access duct covers in this catalogue are designed for installation on prefabricated chambers. In principle, therefore, the frame dimensions are adapted to the chamber rabbet. Check that the strength class of the 2 products (chamber and duct cover) is suitable for the intended purpose. For «non Telecom» use: Check that the chamber seating rim is compatible. The frame must never overhang the free opening. Clean the seating rim and check its strength. Find a sound bearing surface, if necessary excavate...
Open the catalog to page 15All SAINT-GOBAIN CANALISATION catalogs and technical brochures
-
ALPINAL
36 Pages
-
BIOGAN
5 Pages
-
Trenchless pipe laying
17 Pages
-
Pam Academy Brocher
4 Pages
-
TT PE / TT PUX range
40 Pages
-
ROTATABLE FLANGED FITTINGS
11 Pages
-
MUNICIPAL CASTINGS
56 Pages
-
HYDROPAM
9 Pages
-
NATURAL
20 Pages
-
HYDROCLASS
52 Pages
-
BLUTOP
32 Pages