video corpo

Novelio® FireResist

Novelio® FireResist

Novelio® FireResist

Product catalog summary
Fire Safety: The document emphasizes the importance of selecting materials that limit fire spread in building design, particularly for high-rise buildings and public institutions. Novelio® FireResist wall coverings are highlighted for their fire safety, achieving a reaction to fire classification of A2-s1,d0, indicating they are non-combustible, produce virtually no smoke, and do not release burning droplets or debris.
Reaction Classification Fire: Materials are classified from A1 (non-combustible) to F (very easily flammable). Smoke opacity is rated from S1 (low) to S3 (high), and debris projection from D0 (none) to D2. Novelio® FireResist achieves A2-s1,d0, the highest performance level.
Crack and Impact Resistance: These wall coverings provide reinforcement, extending the life of walls or ceilings up to 30 years. They are paintable, allowing for a single coat of acrylic topcoat.
Technical Data: The product is available in 25 m2 rolls of pre-painted fiberglass. The system's fire reaction classification requires specific glue (Novelio® FireResist 7035) and high-quality acrylic paint, with maximum quantities specified to maintain classification.
Product Specifications: The document lists various types of wall coverings with their weight, dimensions, and pallet quantity. The glue is available in 20 kg buckets.
Contact Information: Saint-Gobain ADFORS CZ s.r.o. is the manufacturer, located in Litomyšl, Czech Republic, with contact details provided.
See more

Catalog excerpts

Novelio® FireResist-1

GLASS FIBRE WALLCOVERINGS Novelio® FireResist Paintable fiberglass wallcoverings with reaction to fire class A2 REACTION TO FIRE CLASS A2-s1,d0 (EN 13501) IMPACT RESISTANT

 Open the catalog to page 1
Novelio® FireResist-2

FIRE SAFETY CRACK AND IMPACT RESISTANCE Fire safety begins with the design of buildings and choice of materials. In case of fire, flames or fumes may reach several hundred degrees in a few minutes, if in a confined environment, and cause significant property damage. Not to mention a cost in human lives. Materials used in the construction and development of high-rise buildings and public institutions must be selected on the basis of how they limit the spread of fire, and thus, allow occupants time to evacuate. REACTION CLASSIFICATION FIRE Materials are classified from A1 (non-combustible) to F...

 Open the catalog to page 2

All Saint-Gobain Adfors Europe catalogs and technical brochures

  1. FibaFuse®

    2  Pages

  2. FibaTape®

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.