Catalog excerpts
E/03/08 ISO 9001 - Cert. n 0545/3 Unit heaters Radiant panels Fan coils Air handling units GP - E - 03/08 Flues A4000100 ENVIRONMENTAL COMFORT OD. ENVIRONMENTAL COMFORT C Sabiana s.p.a. > Е via Piave, 53 > 20011 Corbetta > Օ Milano > Italy > Օ phone +39.02.97203.1 r.a. / +39.02.97270429 / +39.02.97270576 fax +39.02.9777282 / +39.02.9772820 > www.sabiana.it > Օ info@sabiana.it > Copertina GUIDA Inglese.indd 1 27-02-2008 12:58:06 size="-3">
Open the catalog to page 1DUCK STRIP RADIANT PANELS: AEROSPATIALE TOULOUSE NEW AIRBUS A380 PRODUCTION PLANT. INSTALLATION HEIGHT: 40 m JANUS 05 AND POLARIS AIR CONDITIONERS DUCK STRIP RADIANT PANELS: AEROSPATIALE TOULOUSE NEW AIRBUS A380 PRODUCTION PLANT. INSTALLATION HEIGHT: 40 m SKYSTAR FAN COIL UNITS CASSETTE >
Open the catalog to page 2Choose SABIANA and you choose safety. Safety in terms of products, performance and reliability. Safety also means a relationship based on honesty and competence. For this reason SABIANA has kept for 80 years a leading position in the production of heating and air conditioning equipment for use in industry, trade and sports. In 1929 SABIANA was founded by Franco Binaghi and Benvenuto Anatrella and began its activity with the production of heating appliances. After > Sabiana production plant having brilliantly overcome the war years and the post-war period, the company adapted its range of...
Open the catalog to page 3Pulsar - Radiant Panels Duck-Strip - Radiant Panels Atlas - Unit Heaters Helios - Unit Heaters Atlas STP - Door Curtain Units AIX - Stainless Steel Unit Heater Jetstream - Induction Flow Optimizers No-Strat - Antistratification Units Meltemi - Door Curtains Energy - Heat Recovery Units Electra 90 and Electramatic - Electric Unit Heaters FSE - Electric Fan Convectors Primula - Fan Convectors Comfort - Circular Unit Heaters > Polaris - Air Conditioners Elegant - Air Conditioners Krio - Chillers Janus 05 - Air Conditioners Futura - Fan Coil Units Futura Serie FSC - Fan Coil Units with...
Open the catalog to page 43/4Д > MALE THREADED CONNECTIONS ( > SUPPLIED NOT MOUNTED ) I > Description Length (mm) Weight (kg) Pulsar P.1 1186 13.8 Pulsar P.2 1786 20.7 Pulsar P.3 2386 27.6 Pulsar P.4 2986 34.5 > NSULATIONHOLDING I > NSULATION 30 > MM THICK ANGING CORNER PIECE STRIP ( > SUPPLIED NOT MOUNTED )H > C > OOLING E > MISSION C > OOLING E > MISSION ∆ > TM With insulation Without insulation ∆ > TM With insulation Without insulation C W / ml W / m > 2 W / ml W / m > 2 аC W / ml W / m > 2 W / ml W / m > 2 5 22 38 30 52 11 53 90 71 122 6 28 47 37 63 12 58 99 79 134 7 32 55 43 74 13 63 108 86 146 8 38 64 50 86 14...
Open the catalog to page 5The radiant panels consist > of three main components: > We have panels with 2 tubes or 3 tubes to provide a > variation of output, these > are then formed into widths > provided in modular lengths of 4 or 6 metres thus accomodating a total strip to the nearest 2 metres. The strip is supplied with 3 sections to make up a complete strip, first, intermediate and final. The first and final include headers and each section is connected to the one before it. The DUCK STRIP panels are completely painted in light GREY, RAL 9002 or in WHITE, RAL 9010 with epoxy-polyester powder dried at 180C....
Open the catalog to page 6Guida Prodotti Inglese.indd 6 27-02-2008 12:55:20 >
Open the catalog to page 8MOTOR MODEL LEAVING NOISE EMISSION LEAVING MOTOR MODEL LEAVING NOISE EMISSION LEAVING > SPEED REF. AIR LEVEL AIR SPEED REF. AIR LEVEL AIR VOLUME at 5 m. TEMP. VOLUME at 5 m. TEMP. > UNIT SIZE r.p.m. ATLAS HELIOS m > 3 /h dB(A) W аC > UNIT SIZE r.p.m. ATLAS HELIOS m > 3 /h dB(A) W C > Example 6A42 SX 6 A-H 4 2 SX SP motor range size rows battery battery 6 pole (900 r.p.m.) Atlas-Helios 4 2 steel tube copper tube > Guida Prodotti Inglese.indd 7 27-02-2008 12:55:23 >
Open the catalog to page 9Unit selection Emission - LTHW 85/70C - EAT +15аC 6 POLE (900 r.p.m.) 8 POLE (700 r.p.m.) SIZE STP MOTOR DOOR DOOR POLE HEIGHT WIDTH SIZE STP H ( m ) L ( m ) 1 Row 2 Rows 3 Rows 1 Row 2 Rows 3 Rows - 70.7 kW 85.7 kW 42C 50簰C - 58.7 kW 70.4 kW 44C 53аC Dimensions WATER SIZE STP A=B C D E N WEIGHT 1011 877 576 991 832 89.5 87 110 18 1 > 1 / > 2Ԕ 150 40 82 92 8.2 12 S > TEAM 6 > BAR W.T. W.T. 85/75C 130/100аC N > OISE LEVEL M > OTOR S > PEED A > IR F > LOW HROW AT SIZE T 5 m E.A.T. E.A.T. E.A.T. > ROWS MODEL +15C +15аC +15C r.p.m. > Y m > 3 /h ТȆ > Y m ∆ > Y dB(A) ∆ > Y kW kW kW ∆ ∆ > Y ∆ > Y...
Open the catalog to page 10MODEL SPEED AIR FLOW MOTOR AMPERE INSTALLAT. SURFACE LEVEL A B C D E HEIGHT at 4 m >
Open the catalog to page 11Working static pressure = 50 Pa M > AIN T > ECHNICAL C > HARACTERISTICS MODEL ENY 1 ENY 2 ENY 3 ENY 4 ENY 5 ENY 6 > 3 High speed Air flow m /h 620 1200 1450 2150 2500 3800 Sound pressure (*) dB(A) 54 56 58 62 60 64 > 3 Medium speed Air flow m /h 535 940 1080 1690 1630 2800 Sound pressure (*) dB(A) 52 52 53 58 58 60 > 3 Low speed Air flow m /h 365 780 840 1040 1270 2230 Sound pressure (*) dB(A) 49 49 48 51 48 56 > (*) Sound pressure measured in an open field at a distance of 1 metre from the fan outlet HEAT RECOVERY UNITS ENY 1 ENY 2 ENY 3 ENY 4 ENY 5 ENY 6 >
Open the catalog to page 12B mm 454 669 454 669 884 1099 1099 L mm 775 990 775 990 1205 1420 1420 The sound pressure levels apply to the reverberant field of a 100 3 room and a reverberation time of 0,5 sec. SD M > ODEL WITH HOT WATER BATTERY - PE M > ODEL WITH ELECTRIC BATTERY A > IR FLOW (m > 3 /h) W > ATER W > ATER 70/60C (SD Mod.) W > ATER 80/70аC (SD Mod.) (PE Mod.) > MODEL M > IN M > AX CONTENTS O > UTPUT W > ATER FLOW ∆ p > DROP O > UTPUT W > ATER FLOW ∆ p > DROP O > UTPUT W > EIGHT Guida Prodotti Inglese.indd 11 27-02-2008 12:55:38 >
Open the catalog to page 13MOTOR AIR NOISE LEVEL EMISSION L.A.T. > SPEED SIZE FLOW at 5 m MODEL > SIZE A B C C1 D F G H I N O P Q R S DN W > EIGHT (kg) W > ATER CONTENT (l) > 680 180 430 560 408 380 460 537 165 460 331 612 62 350 350 1 > 1 / > 4ؔ 25 31 1.20 > Guida Prodotti Inglese.indd 12 27-02-2008 12:55:41 >
Open the catalog to page 14NOISE LEVEL AIR FLOW HEATING: COOLING: R.H. 55% > SIZE at 5 m L.T.H.W. 85/70C - E.A.T. 15аC E.A.T. 28C dB(A) m > 3 /h kW L.A.T. аC L.T.H.W. 11/15C > MOD. M > AX A > X A W > EIGHT S > URFACE M > AX HEIGHT S > URFACE Low speed kW 6.6 8.1 9.5 10.8 12.2 10.1 12.8 15.7 18.3 20.3 refer to the following Emission working conditions: > HEATING Cooling High speed kW - - - - - 4.4 6.1 7.3 8.3 9.8 > Medium speed kW - - - - - 3.8 5.3 6.4 7.0 8.5 Entering air temperature: + 20аC Low speed kW - - - - - 3.2 4.3 5.7 6.2 7.5 Water temperature: + 70/60C > Guida Prodotti Inglese.indd 13 27-02-2008 12:55:45 >
Open the catalog to page 15All Sabiana catalogs and technical brochures
-
Atlas
7 Pages
-
Cool Breeze
6 Pages
-
PULSAR
9 Pages
-
Duck Strip
11 Pages
-
PRODUCT RANGE 2020
446 Pages
-
PRODUCT RANGE 2019
436 Pages
-
InoxSabiana 50
5 Pages
-
Fan Coil Control Range
36 Pages
-
Carisma Fly - Fly-ECM
40 Pages
-
CARISMA COLLECTION
28 Pages
-
Duck Strip 4.1
28 Pages
-
Polaris
5 Pages
-
Product Range 2013
316 Pages
-
Product Range
40 Pages
Archived catalogs
-
DUCK STRIP
12 Pages
-
MISTRAL
2 Pages
-
SLIM
4 Pages
-
SKYSTAR
5 Pages
-
FUTURA FSC
4 Pages
-
PULSAR
6 Pages
-
ELEGANT
4 Pages
-
HELIOS
3 Pages
-
ATLAS
4 Pages