1. Catalogs
  2. Sabiana
  3. Carisma Fly - Fly-ECM
video corpo

Carisma Fly - Fly-ECM

Carisma Fly - Fly-ECM
1 / 40 PagesView full catalog

Carisma Fly - Fly-ECM

Product catalog summary
Introduction
Carisma Fly is a high wall fan coil unit manufactured by Sabiana in Italy, available in four sizes with both standard AC and low energy EC motors. Designed for easy installation, these units are suitable for 2-pipe installations, offering low electric consumption and quiet operation. Sabiana's participation in the Eurovent certification program ensures reliable performance data.
CVP Series
  • Versions and Main Components: Models are available with or without electric heaters and valves, featuring a durable ABS plastic casing, washable synthetic air filter, and tangential fan assembly.
  • Dimensions, Weight, Water Content: Detailed specifications are provided for each model.
  • EUROVENT Certifications: Certified for cooling and heating emissions, fan power, and sound levels.
  • Working Conditions: Operates with water temperatures between 6°C and 70°C, suitable for installation heights of 2 to 3 meters.
  • Emissions and Pressure Drop: Includes detailed emissions data and water pressure drop information.
  • Accessories and Controls: Offers various control options, including wall and remote controls.
CVP-ECM Series
  • Versions and Main Components: Similar to the CVP series, with advanced control options.
  • Dimensions, Weight, Water Content: Specifications are similar to the CVP series.
  • EUROVENT Certifications: Ensures performance reliability.
  • Working Conditions and Emissions: Detailed working conditions and emissions data are provided.
  • Fly ECM Configuration: Specific configurations and control options are detailed.
General Information
  • Management System: Describes a system for networking multiple units.
  • Accessories: A range of accessories is available to enhance functionality and installation.
Specifications
The Carisma Fly series includes models with and without electric heaters, featuring single-phase 230V electric heaters with overheat protection and safety thermostats. Available valve configurations include without valves, with 2-way valves, or with 3-way valves.
Control Options
Various control options are outlined, including manual and electronic controls for fan speed, temperature settings, and seasonal operation modes. Specific controls like WM-T, WM-TQR, and TMO-503-SV2 offer thermostatic control and energy-saving features.
Technical Characteristics
Constructed with durable materials, including ABS plastic casing and copper tube heat exchangers, the fan assembly features a tangential fan with an electronic motor. Detailed dimensions, weight, and water content are provided for each model.
Performance Data
Includes tables with performance data for different models, detailing air flow, cooling and heating emissions, and pressure drops, along with sound power and pressure levels.
Installation and Safety
Installation guidelines include using a cardboard template for wall mounting. Safety features include thermostats for temperature control and overheat protection for electric heaters.
Certifications
Eurovent certifications ensure compliance with industry benchmarks.
Heating and Cooling Procedures
For heating, the entering air temperature is +20°C, and the water temperature is +50°C. Cooling emission data is provided for various water temperatures, with specific data on air flow, cooling total emission, cooling sensible emission, water flow, and water side pressure drop.
Electrical Data
Motor electrical data for models CVP-ECM 1 to 4 are provided, with power consumption ranging from 15W to 30W and current absorption from 0.14A to 0.26A. The nominal installed power for the electric heater is 1000W for models 1 and 2, and 1500W for models 3 and 4, with a nominal power voltage of 230V.
Installation and Operating Conditions
The installation height for models CVP-ECM 1 to 4 ranges from 2 to 3 meters. Operating limits for the Fly-ECM with an electric heater include a maximum ambient temperature of 25°C.
Control Systems
Units can be controlled using various systems, including RT03 infra-red remote control, PSM-DI multifunction control, and T-MB wall control. The MB version supports network control using the Modbus RTU - RS 485 communication protocol, supporting Master/Slave logic for up to 20 units.
Safety Features
The electric heater includes overheat protection and two safety thermostats: one with manual reset and one with automatic reset.
Accessories and Additional Components
Lists available accessories, including valves and condensate drain pumps, with specific codes and specifications. Details on pressure drop for coils and valves are provided, with correction factors for different temperatures.
Wiring and Configuration
The Fly-ECM electric wiring diagram details connections for the controller, inverter circuit board, and motor fan connections, specifying the signal requirements for the 1-10 Vdc control signal used by the inverter.
Overview
Provides detailed technical specifications and operational guidelines for the Carisma Fly series, focusing on the MB version. Outlines various control options, installation requirements, and management systems for efficient operation.
Specifications and Control Options
  • Offers multiple operational modes, including fan ON/OFF thermostatic control, valve ON/OFF control, and simultaneous ventilation control.
  • Temperature-based fan operation is possible with a cut-out T3 probe, activating in heating or cooling modes.
  • Automatic mode switching is facilitated by an optional T2 water probe, with seasonal changes managed via remote contact.
  • Electric heater control is integrated, with specific temperature thresholds for fan operation in winter and summer modes.
Installation and Connectivity
  • The power board includes connections for an infra-red remote control receiver, T-MB wall control, and RS 485 serial connection for network management.
  • Units can be configured in a Master/Slave setup, with a maximum cable length of 800 meters for network connections.
Control Units
  • T-MB Wall Control: Allows for unit control in Master/Slave mode, featuring temperature setting, fan speed adjustment, and weekly programming.
  • RT03 Infra-red Remote Control: Provides remote operation with similar functionalities as the T-MB control.
  • PSM-DI Multifunction Control Panel: Manages up to 60 units, offering individual or group control, weekly programming, and operational parameter adjustments.
Network Management
  • Sabianet Program: A centralized control system for managing Sabiana MB fan coils, offering weekly programming, historical data access, and priority settings over remote controls.
  • SIOS Board: Equipped with relays for controlling remote electric utilities, compatible with Sabianet and PSM-DI panels.
  • Router-S: Facilitates network expansion beyond 60 units, allowing for Master/Slave sub-network creation.
Additional Notes
The document emphasizes that descriptions and illustrations are subject to change for improvement or commercial reasons, without prior notice.
See more

Catalog excerpts

Carisma Fly - Fly-ECM-1

www.eurovent-certification.com www.certiflash.com High Wall Fan Coil Carisma Fly Carisma Fly-E

 Open the catalog to page 1
Carisma Fly - Fly-ECM-2

CVP Serie • Versions and Main Components • Dimension, Weight, Water content • EUROVENT certifications • Working conditions • Emissions • Water side pressure drop • Accessories • Control operations • Wall electronic controls • Electronic control accessories • Controls and units CVP-ECM Serie • Versions and Main Components • Dimension, Weight, Water content • EUROVENT certifications • Working conditions • Emissions • Models with electric heater • Water side pressure drop • Accessories • Fly ECM configuration • Controls and units T and MB versions CVP / CVP-ECM Serie • Controls and units T version...

 Open the catalog to page 2
Carisma Fly - Fly-ECM-3

Carisma Fly CVP Serie SABIANA Fly MODELS WITHOUT ELECTRIC HEATER - All versions are available without valves, with 2 way valve or with 3 way valve fitted in the unit. There are four sizes available in the following versions: CVP without infra-red remote control and without valve CVP-2V without infra-red remote control with fitted 2 way valve CVP-3V without infra-red remote control with fitted 3 way valve CVP-T with infra-red remote control and without valve CVP-T-2V with infra-red remote control with fitted 2 way valve CVP-T-3V with infra-red remote control with fitted 3 way valve CVP-MB with...

 Open the catalog to page 3
Carisma Fly - Fly-ECM-4

Dimension, Weight, Water content Carisma Fly COIL CONNECTIONS ON THE LEFT MOUNTING DIMENSION

 Open the catalog to page 4
Carisma Fly - Fly-ECM-6

Carisma Fly CVP Serie SABIANA Technical features wwweurovent-certification.com www.certiflash.com HEATING (winter operation) Entering air temperature: + 20°C Water temperature: + 50°C E.W.T. Water flow rate as for the cooling conditions The following standard rating conditions are used: COOLING (summer operation) Entering air temperature: + 27°C d.b. / + 19°C w.b. Water temperature: + 7°C E.W.T. / + 12°C L.W.T. (E) = Eurovent certified performance. MIN-MED-MAX = Standard connected speeds. (*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant...

 Open the catalog to page 6
Carisma Fly - Fly-ECM-7

Carisma Fly CVP Serie SABIANA WORKING CONDITIONS - + 70 °C .. + 6 °C contact “SABIANA” technical department ..1000 kPa (10 bars)

 Open the catalog to page 7
Carisma Fly - Fly-ECM-8

CVP Serie Emissions_ Carisma Fly IL CLIMA AMICO Entering air temperature: +27°C - Relative Humidity: 50% WT = Water temperature Speed Pc = Cooling Total emission MAX Ps = Cooling Sensible emission MED Legend = Fan speed = High speed = Medium speed = Low speed = Air flow pressure drop

 Open the catalog to page 8
Carisma Fly - Fly-ECM-9

CVP Serie Emissions_ Carisma Fly ^3 Fan speed High speed Medium speed Low speed Air flow Legend WT = Water temperature Speed Pc = Cooling Total emission MED Ps = Cooling Sensible emission MIN Dp(c) = Water side pressure drop

 Open the catalog to page 9
Carisma Fly - Fly-ECM-10

Fly MODELS WITH ELECTRIC HEATER All versions are available without valves, with 2 way valve or with 3 way valve fitted in the unit. There are four sizes available in the following versions: CVP-E without infra-red remote control and without valve CVP-E-2V without infra-red remote control with fitted 2 way valve CVP-E-3V without infra-red remote control with fitted 3 way valve CVP-T-E with infra-red remote control and without valve CVP-T-E-2V with infra-red remote control with fitted 2 way valve CVP-T-E-3V with infra-red remote control with fitted 3 way valve CVP-MB-E with MB electronic board...

 Open the catalog to page 10
Carisma Fly - Fly-ECM-11

Water side pressure drop CVP Serie Carisma FlyCoil pressure drop Dp Valves pressure drop Kvs 2,5 Pressure drop for mean water temperature of 10°C; for different temperatures multiply the pressure drop figure by the K correction factors in the table.

 Open the catalog to page 11
Carisma Fly - Fly-ECM-12

Electrical diagrams are shown on the installation, use and maintenance manual WM-3V 9066642 Manual 3 speed switch. Without thermostatic control. It can not control the valves.

 Open the catalog to page 12
Carisma Fly - Fly-ECM-13

CVP CVP Serie Wall electronic controls ID ON-OFF switch. Manual 3 speed switch. Manual Summer/Winter switch. Electronic room thermostat for fan control (ON-OFF). Electronic room thermostat for valve control (ON-OFF) (the fan keeps working). • It allows to control the low temperature cut-out thermostat (TMM). • It allows to control the chilled water valve (ON-OFF) and the electric heater (BEL). Dimensions: 135x86x31 mm ON-OFF switch. Manual 3 speed switch. Manual Summer/Winter switch. Electric heater activation button. Electronic room thermostat for fan control (ON-OFF). Electronic room thermostat...

 Open the catalog to page 13
Carisma Fly - Fly-ECM-14

Carisma Fly CVP Serie SABIANA Speed switches - CVP version - • Speed switch (slave). • It allows to control up to 8 units with only one centralized thermostat using one speed switch for each unit. • For controls: WM-T, WM-TQR and TMO-503-SV2.

 Open the catalog to page 14
Carisma Fly - Fly-ECM-15

NTC low temperature cut-out thermostat ID Code To be fitted between the coil fins. When connecting the control, the NTC probe cable must be separated from the power supply wires. To be used with the following controls: WM-TQR. It stops the fan when the water temperature is lower than 28°C and it starts the fan when is higher than 33°C. TMM low temperature cut-out thermostat — ID Code TMM 9053048 To be installed in contact with the hot water circuit. To be used with the following controls only: WM-T. For units working on heating only. It stops the fan when the water temperature is lower than 30°C...

 Open the catalog to page 15
Carisma Fly - Fly-ECM-16

Controls and units T and MB versions All the CVP units can be supplied in T version and in MB version. • The T version includes the infra-red remote control that allows the management of a single unit (the units can not be controlled in a network). • The MB version includes a wide range of controls, including the infra-red remote control (optional extra), which allows to manage one single unit or several units by using the Modbus RTU - RS 485 communication protocol. Units can be managed according to the Master/Slave logic (up to 20 units) or by supervisory controls. The system consists in a MB...

 Open the catalog to page 16
Carisma Fly - Fly-ECM-17

All versions are available without valves, with 2 way valve or with 3 way valve fitted in the unit. There are four sizes available in the following versions: CVP-ECM without infra-red remote control and without valve CVP-ECM-2V without infra-red remote control with fitted 2 way valve CVP-ECM-3V without infra-red remote control with fitted 3 way valve CVP-ECM-T with infra-red remote control and without valve CVP-ECM-T-2V with infra-red remote control with fitted 2 way valve CVP-ECM-T-3V with infra-red remote control with fitted 3 way valve CVP-ECM-MB with MB electronic board and without valve...

 Open the catalog to page 17

Archived catalogs

  1. Cool Breeze

    6  Pages

  2. PULSAR

    9  Pages

  3. Duck Strip

    11  Pages

  4. Product Range

    40  Pages

  5. Polaris

    5  Pages

  6. Duck Strip 4.1

    28  Pages

  7. DUCK STRIP

    12  Pages

  8. MISTRAL

    2  Pages

  9. SLIM

    4  Pages

  10. SKYSTAR

    5  Pages

  11. FUTURA FSC

    4  Pages

  12. PULSAR

    6  Pages

  13. ELEGANT

    4  Pages

  14. HELIOS

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.