AIR TIGHTNESS
60Pages

{{requestButtons}}

Catalog excerpts

AIR TIGHTNESS - 3

ACRYLIC TAPES SELF-EXPANDING PROFILES Products with solvent-free polymeric mixes suitable for regular surfaces such as membranes, wood and OSB. High thermal stability. Product obtained from polyurethane foam. Used to fill in irregular cracks; high elasticity over time. FLEXI BAND page 30 EASY BAND page 31 FROST BAND page 32 DOUBLE BAND page 33 SUN BAND page 34 ALU BAND page 35 KOMPRI BAND page 42 FRONT BAND page 36 FRONT BAND UV 210 page 37 SEAL BAND page 38 SEAL SQUARE page 39 MAXI BAND page 40 Made with refined bitumen and characterised by high elasticity and ability to adhere to porous or...

Open the catalog to page 3
AIR TIGHTNESS - 4

Let's imagine air as a container: at high temperatures its volume increases, thus absorbing more water vapour. When temperatures cool down, on the other hand, air reduces its volume and the ability to absorb vapour; once the saturation point is reached, the excess vapour is eliminated in the form of condensation (water droplets). The continuous air-tight layer prevents internal air from penetrating the thermal shell; the wind-tight layer blocks all external air flows towards the shell, also ensuring waterproofing. They both serve to prevent uncontrolled condensation phenomena. How is a tape...

Open the catalog to page 4
AIR TIGHTNESS - 5

CHOOSE A SEALING PRODUCT OR TAPE Examine the nature of the surfaces and their shape (smooth or rough). Very irregular surfaces require more glue in order to activate the adhesion process. "Water, sudden temperature changes and exposure to UV rays may shorten the service life of the products. Some products can remain functional despite a humid support surface. It is necessary to analyse the mechanical stress to which the product will be subjected once it is working. During the application phase, it is important to reduce tension and elongation down to a minimum. Prior to application, check...

Open the catalog to page 5
AIR TIGHTNESS - 6

'jt.ilisat.ion table A PRODUCT FOR EACH TYPE OF CONSTRUCTION NODE NAIL POINT SEALING OFTECHNICAL GIRDER-BEAM -Q-O-O-®-®"

Open the catalog to page 6
AIR TIGHTNESS - 8

jtflfsatfon table A PRODUCT FOR EACH TYPE OF CONSTRUCTION NODE NAIL POINT DOOR/WALL FRAME-WALL SEALING OFTECHNICAL BEAM-WALL =j=J -©©©©© ©-^^^g

Open the catalog to page 8
AIR TIGHTNESS - 10

UNTREATED PVC, PLEXIGLAS OR PLASTIC PLASTERBOARD AND FIBREBOARD FIBREGLASS POLYSTYRENE MINERAL WOOL WOOD FIBRE PLASTER, CONCRETE AND BRICKS ROUGH OSB, PREFERABLY WITH PRIMER SUPPORT MADE OF BITUMEN AND POLYPROPYLENE SUPPORT WITH APPLIED COATING i.e., ARIES POLYAMIDE SURFACE k.e. CLIMA CONTROL utilisation table A TAPE FOR EACH TYPE OF MATERIAL

Open the catalog to page 10
AIR TIGHTNESS - 11

POLYAMIDE SURFACE k.e. CLIMA CONTROL SUPPORT WITH APPLIED COATING i.e., ARIES SUPPORT MADE OF BITUMEN AND POLYPROPYLENE SMOOTH OSB ROUGH OSB, PREFERABLY WITH PRIMER PLASTER, CONCRETE AND BRICKS WOOD FIBRE MINERAL WOOL UNTREATED PVC, PLEXIGLAS OR PLASTIC application allowed application possible with the adoption of special measures application not recommended CONSTRUCTION MATERIALS

Open the catalog to page 11
AIR TIGHTNESS - 12

UNTREATED PVC, PLEXIGLAS OR PLASTIC PLASTERBOARD AND FIBREBOARD FIBREGLASS POLYSTYRENE MINERAL WOOL WOOD FIBRE PLASTER, CONCRETE AND BRICKS ROUGH OSB, PREFERABLY WITH PRIMER SUPPORT WITH APPLIED COATING i.e., ARIES SUPPORT MADE OF BITUMEN AND POLYPROPYLENE POLYAMIDE SURFACE k.e. CLIMA CONTROL utilisation table A TAPE FOR EACH TYPE OF MATERIAL

Open the catalog to page 12
AIR TIGHTNESS - 13

POLYAMIDE SURFACE k.e. CLIMA CONTROL SUPPORT WITH APPLIED COATING i.e., ARIES SUPPORT MADE OF BITUMEN AND POLYPROPYLENE SMOOTH OSB ROUGH OSB, PREFERABLY WITH PRIMER PLASTER, CONCRETE AND BRICKS WOOD FIBRE MINERAL WOOL UNTREATED PVC, PLEXIGLAS OR PLASTIC application allowed application possible with the adoption of special measures application not recommended CONSTRUCTION MATERIALS

Open the catalog to page 13
AIR TIGHTNESS - 14

APPLICATION SETTINGS Roof and wall in XLAM (Cross Laminated Structure in XLAM (Cross Laminated Timber) Timber). with ventilated wall. Raising on concrete and masonry wall. Frame wall with window (internal view). Frame roof on masonry wall. Frame wall and roof. Roof with micro ventilation. Blockhaus wall and roof with micro ventilation.

Open the catalog to page 14
AIR TIGHTNESS - 15

ROOF AND WALL IN XLAM (Cross Laminated Timber) BUTYL GLUE page 49 NAIL BAND page 53 FLEXI BAND page 30 EASY BAND page 31 FROST BAND page 32 SUN BAND page 34 DOUBLE BAND page 33 SUPRA BAND page 46 KOMPRI BAND page 42 FRAME BAND page 43 PLASTER BAND page 41 NAIL BAND page 53 NAIL PLASTER page 53 GEMINI page 53 BUTYL GLUE page 49 BORDER BAND page 44 MANICA PLASTER KOMPRI BAND page 42 FRAME BAND page 43

Open the catalog to page 15
AIR TIGHTNESS - 16

STRUCTURE IN XLAM (Cross Laminated Timber) WITH VENTILATED WALL BUTYL GLUE page 49 NAIL BAND page 53 NAIL PLASTER page 53 GEMINI page 53 FLEXI BAND page 30 EASY BAND page 31 FROST BAND page 32 SUN BAND page 34 FRONT BAND page 36 KOMPRI BAND page 42 FRAME BAND page 43 GROUND BAND page 48 BYTUM LIQUID page 54

Open the catalog to page 16
AIR TIGHTNESS - 17

MAXI BAND page 40 FLEXI BAND page 30 EASY BAND page 31 FROST BAND page 32 BUTYL BAND page 49 BUTYL GLUE page 49 CONSTRUCTION SEALING page 50 CONNECT BAND page 48

Open the catalog to page 17
AIR TIGHTNESS - 18

RAISING ON CONCRETE AND MASONRY WALL SEAL BAND page 38 KOMPRI BAND page 42 HERMETIC FOAM page 47 SEALING FOAM page 52 SEAL SQUARE page 39 PLASTER BAND page 41 KOMPRI BAND page 42 FRAME BAND page 43 CONNECT BAND

Open the catalog to page 18
AIR TIGHTNESS - 19

HERMETIC FOAM page 47 SEALING FOAM page 52 KOMPRI BAND page 42 HERMETIC FOAM page 47 CONSTRUCTION SEALING page 50 SEALING FOAM page 52 SEAL BAND page 38 NAIL BAND page 53 NAIL PLASTER page 53 GEMINI page 53 BUTYL GLUE page 49 NAIL BAND page 53 NAIL PLASTER page 53 GEMINI page 53 GIPS BAND page 53

Open the catalog to page 19
AIR TIGHTNESS - 20

FRAME WALL WITH WINDOW (INTERNAL VIEW) BUTYL BAND page 49 ROND BAND page 49 CONSTRUCTION SEALING page 50 SEAL SQUARE page 39 PLASTER BAND page 41 FRAME BAND page 43 PROTECT page 48 NAIL BAND page 53 NAIL PLASTER page 53 GEMINI page 53 BUTYL GLUE page 49 PROTECT page 48 CONNECT BAND page 48 PRIMER page 54

Open the catalog to page 20
AIR TIGHTNESS - 21

FRAME BAND page 43 HERMETIC FOAM page 47 SEALING FOAM page 52 ALU BAND page 35 SEAL BAND page 38 BUTYL GLUE page 49 GIPS BAND page 53 MANICA MULTI page 51 MANICA SINGLE page 51 FLEXI BAND page 30 EASY BAND page 31 FROST BAND page 32 SEAL BAND page 38

Open the catalog to page 21
AIR TIGHTNESS - 22

FRAME ROOF ON MASONRY WALL DOUBLE BAND page 33 SUPRA BAND page 46 MEMBRANE GLUE page 52 SUPERB GLUE page 52 TUBE STOPPER page 54 MANICA SINGLE page 51 MANICA MULTI page 51 MANICA PLASTER page 51 TIE BEAM STRIPE page 50 CONNECT BAND page 48 PROTECT page 48 GIPS BAND page 53

Open the catalog to page 22

All ROTHO BLAAS catalogs and technical brochures

  1. WHT PLATE T

    4 Pages

  2. TITAN V

    6 Pages

  3. TITAN S

    13 Pages

  4. Waterproofing

    180 Pages

  5. Screws for wood

    276 Pages

Archived catalogs

  1. Post Bases

    28 Pages