1. Catalogs
  2. Roth Werke GmbH Energie- und Sanitärsysteme
  3. Original Tacker System-Technical Information and Assembly Instructions

Original Tacker System-Technical Information and Assembly Instructions

Original Tacker System-Technical Information and Assembly Instructions
1 / 36 PagesView full catalog

Original Tacker System-Technical Information and Assembly Instructions

Product catalog summary
System Description
The Roth Original Tacker® System is designed for flexible and easy assembly, suitable for various floor plans. It ensures even heat distribution, optimizing room temperature, and is compatible with both alternative and conventional energy systems due to its low operating temperatures. It complies with the German Energy Saving Directive (EnEV) and DIN standards, ensuring high quality and performance.
System Benefits and Applications
The system is applicable in residential, office, and commercial buildings as per DIN EN 1264 and is recognized by DIN test and monitoring marks.
System Components
Key components include Roth System Pipes (DUOPEX S5®, X-PERT S5®+, Alu-Laserflex, PERTEX®), composite panels, manifolds, expansion joint profiles, and various installation tools. Pipes are available in different dimensions and packaging options.
Set-up and Configuration
Coverings on Heated Rooms: Installation involves layers including plaster, skirting board, and Roth System Pipes, with specific screed depths and pipe coverage.
Covers on Unheated Rooms: Additional insulation is required, with installation height varying based on room conditions.
Covers Adjoining Fresh Air: Requires specific insulation to meet DIN EN 1264 standards.
Design Criteria: Maximum screed temperature should not exceed 55°C, with standardized room temperatures and limited surface temperature differences for comfort.
Performance Data
The system's performance is detailed for both heating and cooling modes, with thermal output varying based on installation spacing and offset coefficients.
Installation Requirements
Guidelines include subsurface preparation, joint management, insulation, and necessary tools.
Assembly Instructions
Detailed steps for assembling system components and ensuring proper installation.
Commissioning
Involves load distribution, functional heating, floor covering, and control engineering, with protocols for leak tests and functional heating/cooling.
Standards and Directives
The system complies with relevant standards and directives, ensuring reliability and efficiency.
Guarantee
Details on the warranty and guarantee provided for the system.
Specifications and Standards
The document outlines installation and operational guidelines for the Roth Original Tacker® System, emphasizing compliance with DIN EN 1264, EnEV directives, and DIN 4109 for sound insulation. Key standards include DIN 4726 for piping systems and VDI 2035 for water heating installations.
Installation Procedures
Installation begins with cutting overlapping edges of composite panels or rolls, followed by laying them from right to left. Double-layer installations require offset joints. Recommended tools include tape measures and various open-end spanners. Pipes should be installed at temperatures above 10°C, avoiding sharp edges, and maintaining specified bend radii.
Assembly Instructions
The sequence involves laying edge insulating strips, composite panels, and system pipes, followed by connecting to the Roth manifold. Leak tests are conducted according to DIN 1264 Part 4. Moisture measurement points are essential, and screed application follows specific temperature guidelines.
Commissioning and Testing
Screed should be laid above 5°C, with consistent temperatures during curing. Functional heating is performed according to DIN EN 1264, with moisture content checks before floor covering installation. Leak tests involve pressure testing with water, compressed air, or inert gas, ensuring no pressure drop.
Control Technology and Floor Coverings
Control components for surface heating include single room controls and water precontrols. The document specifies moisture content limits for various floor coverings, ensuring compatibility with the heating system.
Guarantee and Warranty
The Roth Original Tacker® System comes with guarantees and warranty conditions as per the enclosed certificates.
Guarantee and Warranty
The document outlines a guarantee for Roth Floor Heating and Cooling Systems and Pipe Installation Systems, offering a 10-year guarantee for product replacement or repair due to material or production faults, excluding mechanical and electrical parts which have a 12-month guarantee. Conditions include exclusive use of Roth components, adherence to installation instructions, compliance with relevant standards, and immediate reporting of damages.
Insurance Coverage
The company is insured with a coverage amount of 5,000,000 Euros per occurrence for personal and property injuries.
Product Range
The document lists various Roth systems including the Roth Original Tacker System, ClimaComfort Panel System, and others. It also mentions the Roth Radiator Connection System and Domestic Hot Water System.
Innovation and Service
Roth emphasizes early market requirement identification, in-house research, and engineering. The company offers a complete range of certified products, extensive sales network, hotline support, training courses, and fast product availability across Europe.
Product Applications
Roth provides systems for radiant heating and cooling, pipe installations, and shower systems. They also offer storage solutions for domestic water, combustibles, biofuels, rainwater, and wastewater.
Contact Information
Roth Werke GmbH is located in Dautphetal, Germany, with contact details provided for phone, fax, and email.
See more

Catalog excerpts

Original Tacker System-Technical Information and Assembly Instructions-1

Energy Systems Original Tacker System Technical Information and Assembly Instructions Living full of energy

 Open the catalog to page 1
Original Tacker System-Technical Information and Assembly Instructions-2

System description System description and system benefits Possible applications System components Set-up and configuration Coverings on heated rooms Covers on unheated rooms or rooms heated at intervals, adjoining ground Covers adjoining fresh air Design criteria Performance data Performance data Roth Original Tacker® System Ø 14, Heating Performance data Roth Original Tacker® System Ø 14, Cooling Performance data Roth Original Tacker® System Ø 17, Heating Performance data Roth Original Tacker® System Ø 17, Cooling Determining the performance data Example – Performance calculation, heating Example...

 Open the catalog to page 2
Original Tacker System-Technical Information and Assembly Instructions-3

System description System description and system benefits The Roth Original Tacker® System is characterised by a high degree of flexibility and easy assembly, even for unusual floor plans. The heat is emitted evenly across the whole floor structure, thus creating an optimum room temperature. Because of the low system temperatures, alternative energy systems can be ideally combined with the Roth Original Tacker® System a well as conventional heat generation systems. The flooring layout designs of the Roth Original Tacker® System are determined by the requirements of German Energy Saving Directive...

 Open the catalog to page 3
Original Tacker System-Technical Information and Assembly Instructions-4

System description System components Roth System Pipes DUOPEX S5® Roth System Pipes X-PERT S5®+, Roth System Pipe Alu-Laserflex, Roth System Pipes PERTEX® Technical Data Roth System Pipe Pipe dimensions [Wall thickness] Length delivered in a box in a box, to be laid with an unwinding reel in a box in a box in a box, to be laid with an unwinding reel on an unwinding device, in leaf in a box in a box, to be laid with an unwinding reel on an unwinding device, in leaf in a box in a box, to be laid with an unwinding reel in a box in a box, to be laid with an unwinding reel in a box in a box, to be...

 Open the catalog to page 4
Original Tacker System-Technical Information and Assembly Instructions-5

System description System components Roth system composite panel EPS-DES Roth composite roll EPS-DES System composite panels and rolls Insulation height Traffic load Impact sound reduction (min.) Roth edge insulating strips 160 mm Roth expansion joint profile Roth manifold with flow rate indicator, lockable / universal Cement screed additives/Cement screed additives Plus

 Open the catalog to page 5
Original Tacker System-Technical Information and Assembly Instructions-6

System description System components Roth measuring point set Roth uncoiler Roth folding uncoiler Roth antifreeze Roth pipe scissors Roth pipe cutter Roth knife Roth calibration tool

 Open the catalog to page 6
Original Tacker System-Technical Information and Assembly Instructions-7

Cover over heated rooms Wall Plaster Skirting board Elastic grouting Roth edge insulating strip Surface covering variabel variable Plaster as defined in DIN 18560 Roth Pipeholder Roth System Pipe Ø 14 - 20 mm Roth System Composite Panel (alternative: Roth Composite Roll) Load-bearing subsurface Installation height: Covers compared to equivalently heated rooms, according to DIN EN 1264, Rλ, INS = 0,75 m2 K/W Rλ, [m2K/W] D1 System composite panel or roll Htot with E Screed depth at 45 mm Pipe coverage [mm] Htot with E Screed depth at 30 mm Pipe coverage

 Open the catalog to page 7
Original Tacker System-Technical Information and Assembly Instructions-8

Covers on unheated rooms or rooms heated at intervals, adjoining ground Wall Plaster Skirting board Elastic grouting Roth edge insulating strip variabel variable Surface covering Plaster as defined in DIN 18560 Roth Pipeholder Roth System Pipe Ø 14 - 20 mm Htot ges Roth System Composite Panel (alternative: Roth Composite Roll) Sealing against ground moisture according to DIN 18195 and PE film (not required if not adjoining ground) Load-bearing subsurface Installation height: Covers compared to unheated rooms, rooms heated at intervals or soil according to DIN EN 1264, Rλ, INS = 1,25 m2 K/W D1...

 Open the catalog to page 8
Original Tacker System-Technical Information and Assembly Instructions-9

Covers adjoining fresh air Wall Plaster Skirting board Elastic grouting Roth edge insulating strip Surface covering variabel variable Plaster as defined in DIN 18560 Roth Pipeholder Roth System Pipe Ø 14 - 20 mm Roth System Composite Panel (alternative: Roth Composite Roll) Installation height: Covers against fresh air [-5 °C >Td ≥ -15 °C], Rλ, INS = 2,00 m2 K/W No. D1 System composite panel or roll Htot with E Screed depth at 45 mm Pipe coverage [mm] Htot with E Screed depth at 30 mm Pipe coverage [mm] G hen selecting additional insulation, the minimum W requirements according to DIN EN 1264...

 Open the catalog to page 9
Original Tacker System-Technical Information and Assembly Instructions-10

Design criteria Room temperatures for underfloor heating According to DIN EN 12831, the following room temperatures for heated rooms form the basis of the underfloor heating calculation: Room type Standard indoor temperature ϑi [°C] Living rooms and bedrooms Offices, meeting rooms, exhibition rooms Hotel rooms Sales rooms, shops (general) Classrooms (general) Theatre, concert and event rooms Bath and shower rooms, swimming pools, changing rooms, any use in undressed area Heated side rooms (corridors, stairwells) Different temperature requirements must already be provided when calculating the...

 Open the catalog to page 10
Original Tacker System-Technical Information and Assembly Instructions-11

Floor coverings The floor covering can also be considered in the planning project planning phase. So that an optimum set-up and use of the radiant heating is achieved, the thermal resistance of the desired floor covering (RλB) must be applied in the calculation. If the value is not known, the value of RλB = 0,10 m²K/W is used in the calculation. Values of RλB > 0,15 m²K/W for the floor covering can be agreed in writing if the maximum temperatures for inlet, floor surface and screed are not exceeded. Planning guidelines for fully adhesive floor coverings on radiant heating and cooling systems...

 Open the catalog to page 11
Original Tacker System-Technical Information and Assembly Instructions-12

Performance data Performance data Roth Original Tacker® System Ø 14, Heating WTP test report no. 98160002 and 1011001 Heating medium upper temperature ΔϑH [K] Heating medium upper temperature ΔϑH [K] Original-Tacker-System ø screed cover 45 mm, RλB = mm, R Original Tacker System ø 14, 14, Estrichüberdeckung 45 0 Heat output (W/m2)) Heizleistung (W/m Grenzkurve 9 K Limit curve 9 K Grenzkurve 15 K Limit curve 15 K Heating medium upper temperature Δϑ (K) Heizmittelübertemperatur Δϑ (K) Heating medium upper temperature ΔϑH [K] Heating medium upper temperature ΔϑH [K] Original-Tacker-System ø screed...

 Open the catalog to page 12

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.