Safety and Warranty
The document stresses the necessity for skilled personnel to perform installation and electrical work in accordance with local laws. It reserves the company's right to modify product designs for technical advancements. The warranty covers product defects but excludes issues from improper use, installation, or maintenance.
Reference Code
This section details the product coding system, including current type, design, impeller diameter, number of poles, cable outlet, and motor type.
Technical Description
Rosenberg radial fans with free-running impellers are described, highlighting their use in air-handling units. The document specifies materials like aluminum for impellers and emphasizes checking rotation direction to prevent motor overload.
Impeller and Inlet Cones
Impellers are made from aluminum and balanced per DIN ISO standards. Inlet cones are optimized for airflow and made from galvanized steel.
Volume Flow Monitoring
Volume flow is monitored using a ring testing wire on the inlet cone.
Motors
Details on motor types, safety, and speed control are provided, focusing on electronically commutated and IEC standard motors.
Protection and Explosion Safety
Fans require additional safety measures as per DIN standards, and explosion-proof models are available upon request.
Machine Directive Compliance
Fans are CE marked and must comply with the EG Machinery Directive before operation.
Advantages
Advantages include easy installation, maintenance-free operation, and hygiene benefits. Fans can be installed with horizontal or vertical shafts.
Specifications and Features
  • Energy-saving units with external rotor drive and high-performance impeller.
  • Various drive concepts and speed control options.
  • Easy volume flow determination with a measuring device.
  • Vibration decoupling possible.
  • Custom variants easily accommodated.
  • High economic efficiency due to optimized impeller efficiency.
Compliance and Safety
  • CE-marked and comply with EU Machinery Guideline 98/37EG.
  • Operation prohibited until compliance is confirmed.
  • Additional safety precautions in the operation manual as per EC Council Directive 98/37/EC.
Advantages of Radial Fans
  • Easy installation and maintenance.
  • Hygienic and easy to clean.
  • Compact and space-saving design.
Air Performance Curves
  • Established using the inlet test method according to DIN 24163.
  • Valid for air with a density of 1.2 kg/m³ at 20°C.
  • Show pressure increase as a function of volume flow.
Noise Levels
  • Measured according to DIN 45635, part 38.
  • Formulas provided for calculating sound power levels.
Installation Recommendations
  • Maintain an installation ratio of internal casing dimension A > 1.6 times the external impeller diameter D.
  • Minimum distance of 0.5 * D to adjoining parts recommended.
Air Volume Testing Device
  • Consists of a circular lead with pressure measuring devices.
  • Allows control of air volume based on differential pressure measurements.
Product Advantages
  • Compact and space-saving design.
  • Economical due to high efficiency impeller.
  • Installable in all positions and easy to maintain.
Performance Curves
  • Indicate static pressure increase as a function of volume flow.
Specifications and Features
Rosenberg radial fans with free-running impellers, specifically the E/DKHR and E/DKHM series, are compact and optimized for air movement. Motors are protected to IP54 standards and use class F insulation.
Motor Protection
Motors have thermal contacts for temperature monitoring, protecting against overload and other issues. Motor protection control units are recommended.
Electrical Connection
Nominal voltage is specified with a tolerance of ±10%. Standard cable lengths vary by motor size.
Voltage Types and Speed Control
Performance data is provided for standard versions at 50 Hz, 1~230V, and 3~400V. Speed control can be achieved through voltage or frequency control.
Performance Data
Includes detailed performance charts for various fan models, indicating airflow rates, pressure, and noise levels.
Specifications and Installation
Installation and operation of ventilators require only one cable to connect the motor to the EC-controller. Compliance with EMC Directive 89/336/EEC is necessary.
Electrical Connection
Fans are delivered ready for installation with an accessible terminal box. Electrical installation must comply with local regulations.
Accessories
All accessories must be ordered separately, with technical details provided in the catalogue.
Speed Control
Speed control is continuously variable via an external potentiometer.
Performance Curves
Valid only for the allocated commutation units.
Air Temperature
The GKH fan range is suitable for air and non-aggressive gases or steams, with a maximum medium temperature of 40°C.
Technical Data and Performance
Includes detailed performance data for various fan models.
Electronic Commutating Unit
Housed in a metal casing with IP 20 protection, suitable for control box installation.
Specifications
Specifications for EC motors and controllers include compliance with EMC Directive 89/336/EEC.
Functions
EC motors offer speed control via an external 0-10 Volt input signal or an integrated potentiometer.
Technical Data
Provides detailed technical data for different models.
Project Description
Describes a project involving free-running impellers with EC motor drives.
Motor Protection and Electrical Connection
Motors are equipped with PTCs for temperature monitoring.
Speed Control
Achieved through frequency converters.
Performance Curves
Includes performance curves showing static pressure increase as a function of volume flow.
Advantages
Highlights advantages of EC motors, including compact construction and economical operation.
Specifications
Provides detailed specifications for various models of Rosenberg radial fans.
Models
  • DKNB: Includes a motorized impeller with an airflow-optimized inlet cone.
  • DKNM: Features a motorized impeller with an airflow-optimized inlet cone.
Technical Data
Includes tables with detailed dimensions and specifications for various fan models.
Wiring Diagrams
Wiring diagrams for three-phase A.C. motors with PTC resistors are provided.
Accessories
Lists available accessories such as vibration dampers and frequency converters.
Documentation and Compliance
Fans comply with machinery directive 98/37/EEC and other relevant directives.
See more

Catalog excerpts

Free Blowing fans-1

Rosenberg Ventilatoren GmbH Maybachstraße 1/9 D-74653 Künzelsau-Gaisbach Fon +49(0)7940 / 142-0 Fax +49(0)7940 / 142-125 www.rosenberg-gmbh.com [email protected] R a d i a l v e n t i l a t o r e n m i t f r e i l a u f e n d e m R a d ; o h n e G e h ä u s e r a d i a l f a n s w i t h f r e e - r u n n i n g i m p e l l e r ; wi t h o u t h o u s i n g m i t A u s s e n l ä u f e r m o t o r / m i t A u s s e n l ä u f e r - E C - M o t o r / m i t I E C - N o r m m o t o r / w i t h e x t e r n a l r o t o r m o t o r w i t h e x t e r n a l r o t o r E C - m o t o r w i t h I E C - s t a n d a r d m o t o r ECOFIT ETRI T H E A I R M O V E M E N T G R O U P

 Open the catalog to page 1
Free Blowing fans-2

Inhaltsverzeichnis Contents Sicherheit und Garantie Typenschlüssel Technische Beschreibung - Eigenschaften und Ausführung - Laufräder - Drehrichtung - Einströmdüsen - Motoren - Volumenstromüberwachung - Berührungsschutz - Explosionsschutz - Vorteile - Luftleistungskennlinien - Geräusche - Einbauempfehlung - Volumenstrom-Meßeinrichtung Freilaufende Räder mit asynchron Außenläufermotor - Erläuterung zu technischen Daten - Technische Beschreibung - Kennlinien 50 Hz _KH_250-.. W - _KH_710_-.. W - Schnellauswahl 60 Hz - Abmessungen - Schaltbilder - Beispiele - Ausschreibungstext Freilaufende Räder...

 Open the catalog to page 2
Free Blowing fans-3

Bitte beachten Sie beim Einbau und beim Betrieb der Rosenberg-Ventilatoren folgende Hinweise: Montage- und Elektroarbeiten nur durch ausgebildetes und eingewiesenes Fachpersonal und nach den jeweils zutreffenden örtlichen Vorschriften oder Normen. Die aktuell gültige Betriebsanleitung ist einzuhalten! Änderungen in Konstruktion und Design behalten wir uns im Sinne des technischen Fortschritts vor. Qualitätsmanagementsystem DIN EN ISO 9001 Rosenberg-Produkte werden nach modernsten Produktionsverfahren hergestellt. Die konsequente Überwachung der Fertigung durch unser Qualitätsmanagementsystem...

 Open the catalog to page 3
Free Blowing fans-4

Typenschlüssel / Reference code Stromart / Type of current D = Drehstrom / Three phase E = Einphasenwechselstrom / Single phase A.C. G = EC- Motor- Antrieb / EC- Motor Drive Ausführung / Design KH= Freilaufendes Rad mit Außenläufermotor Free running impeller with external rotor motor KN= freilaufendes Rad mit IEC Normmotor Free running impeller with IEC motor Bauform / Type R = Motorlaufrad / Motorized impeller M = Ventilatoreinbaumodul / Fan module B = Ventilatoreinbaumodul mit Montagebock / Fan module with mounting stand Radnenngrösse / Impeller diameter 355 = 355 mm Polzahl / Number of poles...

 Open the catalog to page 4
Free Blowing fans-5

Eigenschaften und Ausführungen Die Rosenberg Radialventilatoren mit freilaufendem Rad sind hauptsächlich für den Geräteeinbau konzipiert und kommen vorzugsweise in Klimageräten, Hygienegeräten, Reinraumfiltereinheiten sowie RLT-Anlagen zum Einsatz. Bei der Entwicklung des rückwärts gekrümmten Laufrades für den Einsatz ohne Spiralgehäuse wurde besonderer Wert auf eine Wirkungsgradoptimierung über einen weiten Kennlinienbereich bei hoher Leistungsdichte und gleichzeitig möglichst optimalem Geräuschpegel gelegt. Die Ventilatoren sind zur Förderung von Luft und sonstigen, nicht aggressiven Gasen...

 Open the catalog to page 5
Free Blowing fans-6

Laufräder Die Laufräder mit 8 rückwärtsgekrümmten Schaufeln werden aus Aluminiumblech (AlMg3) gefertigt und sind zusammen mit der Laufradnabe oder dem jeweils verwendeten Aussenläufermotor entsprechend der Gütestufe G2,5/6,3 nach DIN ISO 1940 statisch und dynamisch gewuchtet. Auf Wunsch können die Laufräder auch aus Stahlblech mit Kunststoffbeschichtung gefertigt werden. Drehrichtung Die Drehrichtung der Laufräder ist serienmäßig rechtsdrehend (gesehen auf die Ansaugseite). Bei falscher Drehrichtung (vorwärtsgekrümmt laufend) besteht Überlastungsgefahr für den Motor. Daher sollte immer vor Inbetriebnahme...

 Open the catalog to page 6
Free Blowing fans-7

Hinweis zur Maschinenrichtlinie Rosenberg Freilaufende Räder sind für den Zusammenbau mit anderen Maschinen / Maschinenteilen zu einer Maschine bestimmt. Sie werden mit dem CE- Zeichen gekennzeichnet und mit einer EG- Herstellererklärung im Sinne der EG Maschinenrichtlinie 98/37EG, Anhang II B ausgeliefert. Die Inbetriebnahme ist solange untersagt, bis festgestellt wurde, dass die durch den Zusammenbau erstellte Maschine den Bestimmungen der EG- Maschinenrichtlinie entspricht. Die Einhaltung der EN 294 bezieht sich nur auf den montierten Berührungsschutz, sofern dieser zum Lieferumfang gehört....

 Open the catalog to page 7
Free Blowing fans-8

Luftleistungskennlinien Die Luftleistungskennlinien wurden auf dem abgebildeten saugseitigen Kammerprüfstand entspechend DIN 24163 aufgenommen. Sie gelten für Luft mit einer Dichte von 1.2 kg/m3 bei einer Temperatur von 20 °C. Die Kennlinen wurden in der Einbauart A (frei saugend, frei ausblasend) aufgenommen und zeigen die saugseitig zur Verfügung stehende Druckerhöhung Ä pfa als Funktion des Volumenstromes. Prüfstand / Test chamber Air performance curves The air performance curves have been established using the inlet test method in the test chamber as shown below according to DIN 24163. They...

 Open the catalog to page 8
Free Blowing fans-9

1 2 4 3 4 5 2 Geräusche Die Messungen und deren Darstellung erfolgt nach DIN 45635, Teil 38, gemäß dem dort beschriebenen Hüllflächenverfahren, nach dem über eine quaderförmige Meßfläche mehrere Meßpunkte erfaßt werden. Nachfolgende Abbildung zeigt schematisch das Messsystem Noise levels The tests and their performance curves were made according to DIN 45635, part 38, in accordance with the envelopesurface method, after data collection at several test points via a square test area. 1 Jalousieklappe 2 Schalldämpfer 3 Prüfling 4 Messgitter 5 Schallmessraum mit reflektierendem Boden 1 shutter door...

 Open the catalog to page 9
Free Blowing fans-11

Die angegebenen Relativpegel wurden über einen Kennlinienbereich von 0,75 bis 1,2 * V opt gemittelt und gelten für Umfangsgeschwindigkeiten von 25 bis 50m/s. Bei Betriebspunkten außerhalb dieses optimalen Einsatzbereiches sind bei tieferen Frequenzen höhere Abweichungen von den Tabellenwerten zu erwarten. Die Oktavschallleistungspegel können in Einzelfällen im Frequenzbereich des Drehtones höhere Werte erreichen als sie mit Hilfe der Tabelle errechnet werden. Grundsätzlich ist zu beachten, dass die Geräuschwerte unter Umständen stark von den Einbaubedingungen, Reflexionen, der vorhandenen Raumakustik...

 Open the catalog to page 11

Archived catalogs

  1. WORLD OF FANS

    450  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.