Safety Instructions: This section emphasizes the importance of following safety symbols and guidelines to prevent hazards such as electrical dangers and crush risks. It stresses the necessity of reading the manual before installation and operation, ensuring the fan is securely mounted with appropriate protection guards, and that only qualified personnel should handle installation and maintenance.
Directed Operation: Fans should only be operated when installed as intended, with safety ensured by equipment according to DIN EN 13857. The manual is specific to the fan described and not applicable to the entire system.
Description and Scope: Rosenberg fans are designed for modern ventilation systems, suitable for air with low dust and slightly aggressive gases. They feature asynchronous external rotor motors for technical advantages, including stepless voltage control. Fans are balanced for optimal performance.
Types of Fans: Various types of fans are described, including radial fans, roof fans, tube fans, in-line duct fans, motor impellers, Unobox and Z-Box, exhaust air units, and axial fans, each with specific features and control capabilities.
Conditions of Use: Fans are suitable for clean air and air with low dust and grease content. The planner must verify the intended operation.
Installation and Maintenance: Detailed procedures for different fan types are provided, emphasizing the need for qualified personnel and adherence to safety standards.
Motor Protection: Thermal contacts in motor windings must be connected to prevent overheating.
Operation: Guidelines for changing the direction of rotation for different motor types and operating conditions, including compliance with the ErP Directive and use with frequency inverters.
Maintenance and Disposal: Instructions for regular maintenance, service, and proper disposal of components are provided.
Service and Compliance: Contact information for service and details on CE marking and conformity declarations are included.
Specifications: Fans are suitable for ventilating clean air, air with low dirt or grease particles, slightly aggressive gases and fumes, mediums with a maximum atmospheric density of 1.2 kg/m3, and humidity up to 95% (non-condensing). The airflow temperature should be between -20°C and the temperature indicated on the data plate.
Storage and Transport: Fans should be stored in their original packaging in a dry, weather-protected environment with temperatures between -20°C and +40°C. Transport should be done using appropriate lifting equipment, avoiding any distortion or damage to the casing.
Installation: Installation and electrical work must be performed by trained personnel following applicable regulations. Fans should not be distorted during installation, and all fastening points must be secured with appropriate means.
Specific Fan Types: Detailed installation instructions for direct-driven radial fans, roof fans, tube fans, in-line duct fans, motor impellers, and axial fans are provided.
Motor Protection: Motors in smaller Rosenberg fans are protected by internal series-connected thermal contacts. For non-voltage controllable motors, a bimetal relay should be adjusted to the motor's rated current.
Commissioning: Before initial operation, ensure proper installation and electrical setup, safety devices are fitted, and the fan area is clear of debris.
Operating Conditions: Fans should not be used in explosive atmospheres and are rated for continuous operation (S1).
Operation with Frequency Inverters: Three-phase Rosenberg fans can operate with frequency inverters if sinusoidal filters are used between the inverter and motor.
Maintenance and Service: Maintenance should be performed by qualified personnel. Ball bearings are maintenance-free under normal conditions but should be replaced every five years.
Disposal: Disposal must comply with local regulations, with an emphasis on environmentally friendly design and disposal practices.
Assembly and Safety Procedures: The document outlines the general mechanics procedure for assembling a machine, emphasizing the importance of securing heavy machine parts.
Component Disposal: Components should be separated into categories for recycling, and materials should be disposed of according to local regulations.
Service and Manufacturer Information: Rosenberg products undergo continuous quality control and comply with current regulations.
CE Marking and Declarations: The document includes a declaration of conformity, stating that Rosenberg products meet applicable EC/EU directives.
See more

Catalog excerpts

FANS-1

Betriebsanleitung Operating instruction DE Ventilatoren / Fans Rosenberg Ventilatoren GmbH · Maybachstraße 1 · 74653 Künzelsau-Gaisbach Tel.: +49(0)7940/142-0 · Fax.: +49(0)7940/142-1

 Open the catalog to page 1
FANS-2

2.1 Bestimmungsmaftiger Betrieb / Directed operation 4 3 Allgemeine Beschreibung, Gultigkeitsbereich / Description, Scope 4 3.1 Hinweis zum Mehrstufenbetrieb / Note on multistage operation 5 3.2 Radialventilatoren mit Direktantrieb / Direct-driven radial fans 5 3.5 Kanalventilatoren / In line duct fans 6 3.9 Abluftboxen mit doppelschaligem Gehause / Exhaust Air Unit with double- walled housing 6 3.10 Axialventilatoren mit Direktantrieb/ Direct driven axial fans 7 5 Lagerung, Transport / Storage, Transport 8 6.1 Radialventilatoren mit Direktantrieb / Direct-driven...

 Open the catalog to page 2
FANS-3

Sicherheit / Safety Folgende Symbole weisen Sie auf bestimmte Gefährdungen hin oder geben Ihnen Hinweise zum sicheren Betrieb. The following symbols refer to particular dangers or give advice for save operation. Achtung! Gefahrenstelle! Sicherheitshinweis! Attention! Danger! Safety advice! Gefahr durch elektrischen Strom oder hohe Spannung! Danger from electric current or high voltage! Crush danger! Lebensgefahr! Nicht unter schwebende Last treten! Danger! Do not step under hanging load! Wichtige Hinweise, Informationen Important information Rosenberg Ventilatoren sind nach dem Stand der Technik...

 Open the catalog to page 3
FANS-4

The fans cannot be used in hazardous areas for the transfer of gas, mist vapours or mixtures. Nor can they be used for the transfer of solid components in the transfer medium. Die in der Wicklung eingebaute Thermokontakte (TK) arbeiten als Motorschutz und müssen angeschlossen werden. The thermal contact (TK) build in the motor winding serve as motor cut-out switches and must be connected! Der Einsatz in explosionsgefährdeten Bereichen zur Förderung von Gas, Nebel Dämpfe oder deren Gemisch ist nicht zulässig. Die Förderung von Feststoffen oder Feststoffanteilen im Fördermedium ist ebenfalls nicht...

 Open the catalog to page 4
FANS-5

Hinweis zum Mehrstufenbetrieb / Note on multistage operation Alle Rosenberg Außenläufermotoren sind für Mehrstufenbetrieb ausgerüstet. Passende Schaltgeräte sind als Zubehör verfügbar. All Rosenberg external rotor motors are equipped for multi-stage operation. Compatible switchgear available as an option. Radialventilatoren mit Direktantrieb / Direct-driven radial fans Radialventilatoren einseitig und doppelseitig saugend sind mit einem Außenläufermotor ausgestattet und sind 100 % stufenlos spannungssteuerbar. Dachventilatoren / Roof fan Dachventilatoren mit Außenläufermotor sind 100 % stufenlos...

 Open the catalog to page 5
FANS-6

Kanalventilatoren / In line duct fans Kanalventilatoren mit Außenläufermotor sind 100 % stufenlos spannungssteuerbar. In line duct fans with external rotor motor are 100 % steplessly voltage controllable. Motorlüfterräder / Motor impellers Motorlaufräder mit Asynchronmotor mit Außenläufermotor sind 100 % stufenlos spannungssteuerbar. Die Motorlaufräder die durch einen dreiphasigen Außenläufermotor bzw. Normmotor betrieben werden können zudem stufenlos über Frequenzumrichter gesteuert werden. Motor impellers equipped with an external rotor motor and they are 100 % steplessly voltage controllable....

 Open the catalog to page 6
FANS-7

3.10 Axialventilatoren mit Direktantrieb/ Direct driven axial fans Axialventilatoren mit Außenläufermotor sind 100 % stufenlos spannungssteuerbar. Axialventilatoren mit quadratischer Einströmdüsenplatte (Baureihe EQ/DQ) bis Baugröße 800 sind serienmäßig mit saugseitigem Berührungsschutzgitter ausgestattet. Ab Baugröße 1000 sind keine Berührungsschutzgitter montiert! - Axial fans with external rotor motor and square plate mounted arrangement, (series EQ / DQ) are supplied with inlet protection guards as standard on sizes up to 800 mm diameter. From size 1000 mm upwards inlet guards are not fitted...

 Open the catalog to page 7
FANS-8

- Lagern Sie den Ventilator in seiner Originalverpackung trocken und wettergeschutzt. - Decken Sie offene Paletten mit Planen ab und schutzen Sie die Ventilatoren vor Schmutzeinwir-kung. - Halten Sie Lagertemperaturen zwi-schen - 20 °C und + 40 °C ein. - Bei Lagerzeitraumen von uber 1 Jahr prufen Sie vor der Montage die Leichtgangigkeit der Lager Drehen mit der Hand). Ebenso sind vor der Inbetriebnahme die Spaltabstande von rotierenden Teilen zu uberprufen (^ Montage). - Nicht am Anschlusskabel trans-portieren. - Transportieren Sie den Ventilator mit den geeigneten Lastaufnah-memitteln (^ Gewicht:...

 Open the catalog to page 8
FANS-9

Fur alle Ventilatoren gilt: - Ventilatoren nicht verspannen! - Verformungen und Verlagerungen durfen nicht zum Anschlagen oder Schleifen bewegter Teile fuhren - Keine Gewalt (hebeln, biegen) an-wenden. - Befestigung an allen Befestigungs-punkten mit geeigneten Befesti-gungsmitteln. - Elektroanschluss nach technischen Anschlussbedingungen und den einschlagigen Vorschriften lt. beige-fugtem Schaltbild - Anschluss nach Anschlussbild (^ Kleber auf Ventilatorgehause) - Kabel ordnungsgemaft in An-schlusskasten einfuhren und ab-dichten (evtl. „Wassersack“) - Potentialausgleichsystem ordnungsgemaft anschlieften...

 Open the catalog to page 9
FANS-10

Radialventilatoren mit Direktantrieb / Direct-driven radial fans - Installation of fans up to size 280/282 as well as DZAE/D all sizes, on the outlet flange or on mounting feet, from size 314/315 on the mounting feet. Ventilatoren nicht verspannen! Beliebige Einbaulage Radial fans can be mounted in any position; Montage von Ventilatoren bis Baugröße 280/282, sowie DZAE/D alle Baugrößen, an den Ausblaswinkelrahmen oder den dafür vorgesehenen Fußwinkeln; ab Baugröße 314/315 an den Fußwinkeln. Zur Befestigung am Ausblaswinkelrahmen nur selbstsichernde Schrauben verwenden! With installation on outlet...

 Open the catalog to page 10
FANS-11

Rohrventilatoren / Tube Fans - Directly connected in the tube system, without special fixation, only possible with damps up to size 250L.with clamps and suitable hanging mounts (e.g. punched metal tapes) ⇒ Padded clamps reduce noise transmission extremely! Zur Befestigung der Rosenberg Montagekonsolen an den Stahlrohrventilatoren dürfen Schrauben, welche nicht länger als 10 mm ins Gehäuseinnere ragen, in das Rohrventilatorgehäuse eingedreht werden. To fix the assembly consoles at the steel tube fans screws, which do not rise up longer than 10 mm in the housing inside, may be pivoted into the...