Overview
This document outlines the technical specifications and guidelines for Rosenberg Ventilatoren's AND/B axial flow fans, which feature adjustable blades and are available in standard, explosion-proof, and smoke fan designs.
Specifications
  • Performance: Capable of pressure increases up to 1,200 Pa and volume flows up to 85,000 m³/h.
  • Temperature Range: Operates from -20°C to +40°C, with options for up to 100°C.
  • Materials: Casings made of hot-dip galvanized steel, with optional plastic coating.
  • Installation: Suitable for both vertical and horizontal installation.
Warranty and Safety
  • Warranty: Covers faulty products with options for replacement or repair, excluding misuse or improper installation.
  • Safety Compliance: Conforms to EC directives and VDMA standards, marked with a CE label.
Technical Description
  • Casings: Made of galvanized steel, available with service access and various accessories.
  • Impellers: Aluminum construction with adjustable blade angles, balanced according to DIN ISO 1940.
  • Motors: IEC standard motors, available in configurations including explosion-proof and smoke fan versions.
Special Designs
  • Explosion-Proof: ATEX certified, suitable for zones 1 and 2.
  • Smoke Fans: Certified according to EN 12101-3, available in F300 and F400 versions.
Performance Curves and Installation
Includes detailed performance curves for fan sizes (AND 315 to ANDB 1000) and installation guidelines, with wiring diagrams and airflow direction considerations.
Additional Specifications
The document details motor compatibility (2-pole and 4-pole motors) and accessories like galvanized or plastic-coated steel feet, vibration dampers, and flexible connections.
Procedures
Performance curves are measured according to DIN 24163 standards, and noise levels are measured as per DIN 45635 and VDI 3731 standards.
Standards
Adheres to DIN 24163 for performance measurement, DIN 45635 for noise measurement, and EN 13857 for protection guard standards.
Recommendations
Consider pressure losses due to protection guards (approximately 5%) and ensure fans are mounted upright for optimal performance.
Key Data from Tables
Includes volume flow units and conversions, pressure unit conversions, and sound power frequency spectrum data for different fan sizes and blade configurations.
Fluid Flow Rules
Changes in wheel diameter and speed affect volume flow, pressure, and power requirements proportionally, with density changes affecting pressure and power requirements.
See more

Catalog excerpts

AND/B Axial Flow Fans-1

ECOFIT ETRI T H E A I R M O V E M E N T G R O U P RosenbergVentilatoren GmbH Maybachstr. 1/9 D-74653 Künzelsau-Gaisbach Fon +49 (0)7940 / 142-0 Fax +49 (0)7940 / 142-125 www.rosenberg-gmbh.com [email protected] AND/B AXIALVENTILATOREN mit verstellbaren Schaufeln in Standardausführung, explosionsgeschützt und Brandgas AND/B AXIAL FLOW FANS with adjustable blades as standard fans, explosion proof design and smoke fans

 Open the catalog to page 1
AND/B Axial Flow Fans-2

Sicherheit und Gewährleistung / Safety and Warranty Gewährleistungsbestimmungen Für die Auswahl, Auslegung und den Einsatz der Ventilatoren ist der Käufer verantwortlich. Für Sach- und Rechtsmängel der Lieferung leistet der Lieferer unter Ausschluss weiterer Ansprüche - vorbehaltlich Abschnitt VII der gültigen Allgemeinen Geschäftsbedingungen (AGB) - Gewähr. Keine Gewähr wird insbesondere in folgenden Fällen übernommen: Ungeeignete oder unsachgemäße Verwendung, fehlerhafte Montage bzw. Inbetriebsetzung durch den Besteller oder Dritte, natürliche Abnutzung, fehlerhafte oder nachlässige Behandlung,...

 Open the catalog to page 2
AND/B Axial Flow Fans-3

Technical description Casings Impellers Motors Safety protection Special designs - explosion proof - smoke fan Accessories Measuring method for performance curves Noise level measurements relative octave sound power level Fluid flow rules of operation for fans Type Code AND + ANDB Dimensions Accessories Overview of article numbers AND Performance curves AND 315 Performance curves AND 400 Performance curves AND 500 Performance curves AND 630 Performance curves AND 710 Overview of article numbers ANDB Performance curves ANDB 560 Performance curves ANDB 630 Performance curves ANDB 710 Performance...

 Open the catalog to page 3
AND/B Axial Flow Fans-4

Axialventilatoren AND + ANDB / Axial fans AND + ANDB Technische Beschreibung Axialventilatoren mit verstellbaren Laufschaufeln decken aufgrund ihrer großen Variationsmöglichkeiten bei Nabenverhältnis, Flügelzahl und Schaufelwinkel einen breiten Leistungsbereich ab. So können mit der Rosenberg- AND/ANDB-Axialreihe Druckerhöhungen bis zu 1.200 Pa und Volumenströme bis 85.000 m3/h realisiert werden. Die zulässigen Fördermitteltemperaturen reichen standardmäßig von -20 °C bis +40 °C (Angaben des Motorherstellers beachten ; höhere Fördermitteltemperaturen bis max. 100°C Dauertemperatur auf Anfrage!)...

 Open the catalog to page 4
AND/B Axial Flow Fans-5

Axialventilatoren AND + ANDB / Axial fans AND + ANDB Impellers The axial impellers are balanced on quality level G 6,3 according to DIN ISO 1940. The hubs of chilled casting aluminium are made in two parts and have removal drillings for easy dismounting of the impeller. Diameter of hub and number of blades see page 10. The profiled blades are made of aluminium diecast, in standstill the blade angles are adjustable. If the blade angle is adjusted after delivery the power requirement must be checked for overload of the motor. The impeller has to be balanced after blade adjustment. The blade angle...

 Open the catalog to page 5
AND/B Axial Flow Fans-6

Axialventilatoren AND + ANDB / Axial fans AND + ANDB Sonderausführungen: - mit Revisionsklappe Die Revisionsklappe ermöglicht Wartungs- und Reinigungsarbeiten am Ventilator im eingebauten Zustand. Beim Einbau des Ventilators ist darauf zu achten, dass sich die Klappe öffnen läßt. - explosionsgeschützt Die Axialventilatoren AND / ANDB sind auch in explosionsgeschützter Ausführung verfügbar. Die maximale Wellenleistung ist auf 15 kW beschränkt. Die maximale Umfangsgeschwindigkeit ist hier auf 62 m/s (AND-Ex) bzw. 79 m/s (ANDB-Ex) reduziert. Explosiongeschützte Ventilatoren sind nach Atex mit der...

 Open the catalog to page 6
AND/B Axial Flow Fans-7

Axialventilatoren AND + ANDB / Axial fans AND + ANDB Zubehör (Feuerverzinkt = Standard; Kunststoffbeschichtet bzw. Edelstahl = Sonder, auf Anfrage) Füße aus Stahl feuerverzinkt oder kunststoffbeschichtet Die Füße gewährleisten hohe Standfestigkeit und einfache Montage stehend oder hängend. Schwingungsdämpfer Die Schwingungsdämpfer gewährleisten eine hohe Laufruhe und lassen sich einfach an den Füßen montieren. Der Ventilator muss auf den Füßen stehend montiert werden. Manschette mit zwei Stahlflanschringen feuerverzinkt Durch den Einsatz von flexiblen Verbindungen werden keine Schwingungen vom...

 Open the catalog to page 7
AND/B Axial Flow Fans-8

Axialventilatoren AND + ANDB / Axial fans AND + ANDB 6) Bremssiebe / screens 7) Meßkammer / measuring chamber 8) Strömungsgleichrichter / straightener 9) Druckanzeige pfa mit Druckentnahmestelle / pressure manometer pfa 10) Prüfling / tested fan 1) Einlauf-Messdüse / inlet cone 2) Wirkdruckanzeige p mit Druckentnahmestelle / pressure measurement point 3) Hilfsventilator / auxiliary fan 4) Übergangsstücke / transistion piece 5) Drosselklappe / reducing damper Messverfahren für Luftleistungskennlinien Die Luftleistungskennlinien wurden auf dem unten abgebildeten saugseitigen Kammerprüfstand entsprechend...

 Open the catalog to page 8
AND/B Axial Flow Fans-9

Axialventilatoren AND + ANDB / Axial fans AND + ANDB Der ausblasseitige Schalldruck in 1m Abstand im reflexionsarmen Raum lässt sich ungefähr ermitteln, indem man von der ausblasseitigen Schalleistung 11 dB subtrahiert. Die Schalldruckdifferenz von Abstand 1m auf Abstand a errechnet sich zu Lp = 10 * log (1/a). Dabei ist zu beachten, dass Reflexionen und Raumcharakteristik sowie Eigenfrequenzen die Größe des Schalldruckpegels unterschiedlich beeinflussen. Unter der Annahme, LW5 LW6, bzw. LWA5 LWA6 können die ausblasseitigen Schallwerte auch für die Saugseite der Ventilatoren übernommen werden...

 Open the catalog to page 9
AND/B Axial Flow Fans-10

Axialventilatoren AND + ANDB / Axial fans AND + ANDB Bei Änderung des Raddurchmessers von geometrisch ähnlichen Rädern bei gleicher Drehzahl: Der Volumenstrom ändert sich proportional der dritten Potenz des Raddurchmessers Die Drücke (statisch, dynamisch, Gesamt-) ändern sich proportional dem Quadrat des Raddurchmessers Der Leistungsbedarf ändert sich proportional der fünften Potenz des Raddurchmessers In the case of changes in the wheel diameter of geometrically similar wheels at constant speed: The volume flow changes cube to the wheel diameter All pressures (static, dynamic and total) change...