AIR HANDLING UNITS

AIR HANDLING UNITS
1 / 36 PagesView full catalog

AIR HANDLING UNITS

Product catalog summary
Overview
The document details Rosenberg Ventilatoren GmbH's air handling units, focusing on their application in the Mexican Embassy in Berlin. These units are designed to efficiently transport and process fresh air to ensure a comfortable indoor environment.
Specifications
The units include components such as outside-air connections, filter chambers, heat recovery systems, and sound attenuation systems. They are equipped with prefilters (minimum F5) and main filters (minimum F7) to ensure air purity.
Functionality
The units provide fresh, clean, and tempered air, removing impurities, cooling in summer, and heating in winter. They include humidification for dry conditions and sound absorbers to minimize noise.
Housing
The housing is made from aluminum or high-quality steel with panel thicknesses of 20 mm, 40 mm, and 60 mm. They are available in weatherproof or hygienic designs and certified to RAL standards.
Installation and Maintenance
Designed for easy installation and maintenance, the units feature adjustable hinges, lever locks, and doors that open 180 degrees. Modules are connected with stable gusset plates and sealed joints to prevent air leakage.
Frame and Panel Construction
The frame is made of closed hollow chamber profiles with plastic or aluminum diecast corner joints. Panels are double-layered with non-flammable, sound, and heat-insulating mineral wool.
Module Connection and Sealing
Modules are connected using stable gusset plates, with joints sealed by microcellular rubber.
Floor Tanks and Installation
Stainless steel or aluminum floor tanks ensure smooth runoff of condensation in humid areas.
Baseframes
Baseframes are made from galvanized sheet steel or welded square hollow sections, depending on module size.
Fans
Rosenberg fans offer cost-effective solutions with free-running impellers and EC or external rotor motors for high efficiency.
Motor Technology
IEC standard motors are used for direct drives, offering high efficiency and low energy consumption.
Energy Consumption and Efficiency
Units use EC motors for high efficiency and energy savings, with heat recovery systems for additional energy savings.
Innovative Drive Technology
EC motors provide high efficiency and energy-saving capabilities, with integrated control systems for reduced operating costs.
Innovative Air-Conditioning Technology
Heat recovery systems significantly reduce operating costs by transferring thermal energy from exhaust to supply air.
Heaters and Coolers
Finned heat exchangers are used for temperature control, with materials ranging from copper/aluminum to stainless steel.
Air Filters
Various filter types ensure supply air quality surpasses outside air, with microbe-safe designs to prevent hygiene issues.
Air Hygiene
Units are certified to VDI 6022 and DIN 1946 standards to address air hygiene concerns.
Humidifiers
Humidifiers maintain adequate air humidity, with types including spray, evaporation, vapour, and high-pressure humidifiers.
Sound Attenuators
Sound-insulating plates absorb air-borne sound, with adjustable noise reduction.
Weatherproof Design
Weatherproof units feature corrosion protection and UV-resistant components for durability.
Hygiene Design
Units include epoxy resin-coated heat exchangers and stainless steel frames, complying with hygiene standards.
Control Systems
The "Airtronic" series offers advanced DDC technology for remote operation and customization.
Rosenberg TR Compact Control Series
Designed for effective temperature control, featuring a user-friendly operating panel and microprocessor-based controller.
Quality and Service Offerings
Rosenberg provides specialist installation engineers, system regulation, performance measurements, and training.
Pre-Installation Requirements
Requirements include building plans, site conditions, installation deadlines, and access permits.
Global Presence
Rosenberg has an extensive international presence, ensuring global availability and support for their products and services.
See more

Catalog excerpts

AIR HANDLING UNITS-2

Standort mit Tradition Location with tradition "gH il H ""h i)

 Open the catalog to page 2
AIR HANDLING UNITS-8

| Pas G eh a use / Ihe housing Gehuse housing L

 Open the catalog to page 8
AIR HANDLING UNITS-11

Der Ventilator / the fan Durch den Einsatz von lEC-Normmotoren als direkten Antrieb fur die freilaufenden Rder des mittleren und groBen Leistungsspektrums ergeben sich viele Vorteile. Die lEC-Normmotoren sind weltweit standardisiert und werden dem Leistungsbedarf des Laufrades optimal angepasst, so dass der Ventilator mit hohem Wirkungsgrad und geringem Energiebedarf betrieben werden kann. Using IEC standard motors as direct drives for the free-running impellers in the medium and high performance ranges provides many benefits. IEC standard motors are standardised worldwide and are adjusted to...

 Open the catalog to page 11
AIR HANDLING UNITS-12

Energieeinsparung / energy consumption Energie energy ^^^^^^^^^^^^^^^^^^^^^^ STOP ■ Energieverbrauch senken reduce power consumption Betriebskosten sparen saveon operating costs Umwelt schonen protect the environment 11

 Open the catalog to page 12
AIR HANDLING UNITS-13

Energieeinsparung / energy consumption Innovative Antriebstechnik: Elektronisch kommutierte AuBenlufermotoren (EC) Vorteile: - sehr hoher Wirkungsgrad - Energieeinsparung - Drehzahl stufenlos steuerbar - kleine MotorbaugrBe - Regelung im Gerഠt integriert Durch den Einsatz von EC-Motoren tragen Rosenberg-Klimagerte zur effizienten Reduzierung von Betriebskosten bei. Innovative drive technology: Electronically commutated external rotor motors (EC) Benefits: - very high degree of efficiency - energy saving - continuously controllable rotation speed - small motor size - integrated control in appliance...

 Open the catalog to page 13
AIR HANDLING UNITS-14

Wrmerckgewinnung / heat recovery W๠rmerckgewinnung heatrecovery Das grBte Energieeinsparpotential in der Klimatechnik bieten die W鴠remrckgewinnungssysteme, da sie die Wrmeenergie der Abluft zur Zuluft 頹bertragen. Ein hoher Wirkungsgrad der Wrmerckgewinnung senkt die Betriebskosten einer RLT-Anlage erheblich. Heat recovery Systems offer the greatest energy-saving potential in air-conditioning technology, as they transfer the thermal energy from the exhaust air to the supply air. A high degree of heat recovery efficiency considerably reduces the operating costs of an RLTsystem. Die Plattenw๠rmetauscher...

 Open the catalog to page 14
AIR HANDLING UNITS-15

Wrmerckgewinnung / heat recovery Der regenerative Rotationsw๠rmetauscher (RWT) kann hchste Wrmer䠹ckgewinnungsgrade von bis zu 85% erreichen. Dabei ist der Rotor auch noch die platz-sparendste Form der Wrmerckgewinnung. Die Rotor-speichermasse besteht in der Grundausstattung aus gewickeltem Aluminium-Wellblech, dar๹ber hinaus sind aber auch hydroskopische Materialien verfgbar. Neben dem reinen Wrme頹bertrger (Kondensations-rotor) stehen damit auch Wrme- und Feuchte࠹bertrger (Enthalpierotor) in verschiedensten Durchmessern zur Verfgung. Gr๴Bere RWT werden segmentiert geliefert und vor Ort zusammengesetzt....

 Open the catalog to page 15
AIR HANDLING UNITS-16

Erhitzer & Khler / heaters & eoolers Erhitzer & Kuhler heaters & eoolers Fur ein angenehmes Klima ist die Lufttemperatur sehr wesentlich. Daher spielen Lufterhitzer und Kuhler in den RLT-Gerten eine groBe Rolle. Haupts頠chlich werden Lamellenwrmetauscher als Erhitzer oder Kuhler verwendet. Die hierbei einge-setzten Materialien gehen von Kupfer/Aluminium (Rohr/Lamelle) uber Edelstahl (Rohr & Lamelle) bis hin zu komplett stahlverzinkten Lamellenwrmetau-schern. Die Rahmen der Erhitzer sind aus verzinktem Stahl gefertigt. Bei den Rahmen fur Kuhlregister werden dagegen standardmࠠBig Aluminium oder...

 Open the catalog to page 16
AIR HANDLING UNITS-17

Erhitzer & Khler / heaters & eoolers Neben dem allseits verwendeten Heiz- bzw. Khlmedium Wasser ist auch die Verwendung von Wasser/Glycol Gemischen m鹴glich. Bei Direktverdampfern sind eine Vielzahl von Kltemitteln verwendbar. Um eine gute Anschluss-mglichkeit der Wഠrmetauscher an das Rohrnetz zu gewhrleisten, sind die standardmBigen Kupfer- bzw. Stahlsammler mit AuBengewindeanschluG versehen. Auf Wunsch sind Gewindeflansche inkl. Gegenflansch erhࠠltlich. Die Rohrdurchfhrungen sind abgedichtet und bei Khlregistern auch durchgehend mit einem dampfdiffusionsdichten Material isoliert. It is also...

 Open the catalog to page 17
AIR HANDLING UNITS-18

Filter / tttter Filter filter Der Gesetzgeber verlangt, dass die maschinell gefr-derte Zuluft von hherer Qualit䴠t ist, als die angesaugte AuBenluft. Um diesen Anforderungen in unseren RLT Gerten gerecht zu werden, setzt Rosenberg auf eine Vielzahl abgestimmter Filtertypen. Dies sind neben den bekannten Taschenfiltern auch Panel- oder Z-Linefilter Da der Filter fr die Lufthygiene sehr wesentlich ist, jedoch bei nicht ordnungsgem๠Ber Wartung und Inspektion zu einem hygienischen Problem werden kann, werden mikrobiell unbedenkliche Filter eingesetzt. Legislation requires that the mechanically transported...

 Open the catalog to page 18
AIR HANDLING UNITS-19

Filter / filter Die bekannten Taschenfilter sind als Kurz- und Langtasche in allen gngigen Filterklassen lieferbar. Zustzlich sind die Taschenfilter in biostatischer Aus-f࠹hrung oder fr den Gefahrenbereich von explosions-gefhrdeten Umgebungen gern頠B ATEX-Richtlinie ver-fgbar. The well-known pocket-type filters can be supplied as short or long pocket type in all current filter classes. The pocket-type filters are also available in biostatic design or for hazardous areas in explosive environments in accordance with ATEX guidelines. Das Klemmschienensystem (bis Gertebaugr頴Be 20Q verfgbar) ermglicht...

 Open the catalog to page 19
AIR HANDLING UNITS-20

Lufthygiene / hygienic air hygienic air 19

 Open the catalog to page 20
AIR HANDLING UNITS-21

Lufthygiene / hygienic air .uft - ein Lebensmittel Air - a vital lment Unsere Gesellschaft hat l驠ngst erkannt, dass Luft, genauso wie Wasser, zu den wichtigsten Grund-elementen des Lebens gehrt. Wird die Lufthygiene vernachlssigt? Im Mittelpunkt der Betrachtung bei Planung und Betrieb steht die Lufthygiene noch nicht, obwohl dies dringend erforderlich ist. Allein die Aussage 䠄Luft - ein Lebensmittel" belegt den hohen Stellwert der Lufthygiene. Die sich aus mangelnder Lufthygiene ergebenden Nachteile schr͠nken nicht nur die Behaglichkeit ein, sondern beeintrchtigen auch die Gesundheit der Menschen...

 Open the catalog to page 21
AIR HANDLING UNITS-22

Befeuehter / humidifiers Befeuehter humidifiers Neben der Temperatur ist auch eine ausreichende Luftfeuchtigkeit fur ein behagliches Raumklima von Bedeutung. Zu den einsetzbaren Befeuchtertypen ge-hren neben dem Spruh- und Verdunstunsgbefeuch-tern auch die Dampf- oder Hochdruckbefeuchter. Adquate air humidity is important for a comfortable atmosph䩨re as well as temprature. Vapour or high-pressure humidifiers as well as spray and evaporation humidifiers are suitable types of humidifiers. Die Spruhbefeuchter verteilen mit Hilfe von feinen Dusen Wasser groBflchig im Luftstrom. Das nicht von der...

 Open the catalog to page 22

Archived catalogs

  1. WORLD OF FANS

    450  Pages