NyRock® Rainscreen 032
10Pages

{{requestButtons}}

Catalog excerpts

NyRock® Rainscreen 032 - 1

Technical datasheet NyRock® RainScreen 032 Version 1.03 September 2023 NyRock® RainScreen 032 Low lambda non-combustible stone wool insulation for ventilated facades NyRock RainScreen 032 is a stone wool insulation product specifically developed for use within ventilated cladding systems, as well as sealed systems such as curtain walling. Manufactured using patented technology, NyRock RainScreen 032 has a more efficient fibre structure that increases the density of air pockets trapped within each slab. This results in an improved thermal performance when compared to traditional stone wool products. Once installed, the product’s high density works in combination with a factoryapplied water repelling agent to give improved resistance to rain ingress during construction. The product can be easily fitted around brackets and other awkward details, and when tightly butted, adjacent slabs effectively ‘knit’ together to provide a continuous insulating layer, reducing heat losses that would otherwise be caused by gaps. For optimum thermal performance in framed structures, combine NyRock RainScreen Slab 032 with NyRock Frame Slab 032. • Independently tested acoustic benefits Water repellent yet breathable Stone wool is dimensionally stable and has been proven to provide the same performance for more than 55 years after installation.* Can be recycled and reprocessed, reducing landfill costs, with zero ODP and GWP. Low lambda non-combustible insulation for use within facade systems. NyRock RainScreen Slab 032 is manufactured using patented NyRock technology for low lambda performance. In addition to thermal comfort, NyRock RainScreen Slab provides independently-tested acoustic benefits. *FIW, Durability Project Mineral Wool (2016), “Conclusions and Outlook.” Available via EURIMA (European Insulation Manufacturers Association) at https://www.eurima.org/uploads/ModuleXtender/Publications/168/2017-02-21_EURIMA-55YearsOfUse_Info_Sheet_V08_final.pdf For more information visit rockwool.com/uk

Open the catalog to page 1
NyRock® Rainscreen 032 - 2

APPLICATIONS NyRock RainScreen 032 is suitable for use on the following construction types: • Steel frame, timber frame or masonry walls in conjunction with a cladding system; Steel frame or timber frame with a masonry outer leaf For more information visit rockwool.com/uk

Open the catalog to page 2
NyRock® Rainscreen 032 - 3

NyRock RainScreen 032 PERFORMANCE Thermal performance Thermal conductivity = 0.032 W/mK Acoustic performance As demonstrated by independent in-situ laboratory testing, NyRock RainScreen 032 helps to reduce the transfer of airborne noise - with results for typical systems as high as Rw 60 dB. Fire performance Rated Euroclass A1 when assessed to EN 13501-1 using test data from reaction-to-fire tests. Water resistance ROCKWOOL stone wool repels liquid water due to its fibre orientation and the presence of water-repellent additives. Condensation control The vapour resistivity of ROCKWOOL...

Open the catalog to page 3
NyRock® Rainscreen 032 - 4

Cladding system in conjunction with steel frame filled with NyRock Frame Slab 032 NyRock RainScreen 032 on 100mm deep metal studs at 600mm centres with 100mm NyRock Frame Slab 032 installed within the frame. NyRock RainScreen 032 NyRock Frame Slab 032 (mm) Insulation fixing Breather membrane Sheathing board Cladding support bracket Cladding panel Secondary frame NyRock RainScreen 032 on 150mm deep metal studs at 600mm centres with 150mm NyRock Frame Slab 032 installed within the frame. NyRock Frame Slab 032 (mm) Plasterboard lining Additional insulation U-values shown have been calculated...

Open the catalog to page 4
NyRock® Rainscreen 032 - 5

Masonry outer in conjunction with steel frame filled with NyRock Frame Slab 032 NyRock RainScreen 032 on 100mm deep metal studs at 600mm centres with 100mm NyRock Frame Slab 032 installed within the frame. NyRock RainScreen 032 (mm) NyRock Frame Slab 032 (mm) Plasterboard lining Secondary frame NyRock Frame Slab 032 Sheathing board NyRock RainScreen 032 with channel restraint system on 140mm or 150mm deep studs at 600mm centres with 140mm NyRock Frame Slab 032 installed within the frame. NyRock RainScreen 032 (mm) NyRock Frame Slab 032 (mm) Breather membrane Facing brickwork Typical...

Open the catalog to page 5
NyRock® Rainscreen 032 - 6

NyRock RainScreen 032 PRODUCT INFORMATION Length (mm) Available in a range of sizes between 50mm and 200mm. Please see current price list for availability. STANDARDS AND APPROVALS Certificate BBA (British Board of Agrément) Certified for use in ventilated rainscreen cladding systems on both domestic and non-domestic buildings. Certificate no. 22/6417 CERTIFICATE 22/6417 NyRock RainScreen 032 satisfies the requirements of BS EN 13162 – “Thermal insulation products for buildings. Factory made mineral wool (MW) products”. INSTALLATION Work on site NyRock RainScreen 032 is supplied in...

Open the catalog to page 6
NyRock® Rainscreen 032 - 7

Slabs should be close-butted at all vertical and horizontal joints. The horizontal joints of the insulation should be staggered in accordance with good practice. Fixings should have a minimum head diameter of 70 mm. A typical fixing pattern has three fixings per square metre with one metal fixing at the centre of every slab (see Figure 1). The product should be cut and tightly fitted around cladding support elements. For a typical installation, a breathable membrane is placed between the sheathing board and the product (see Figures 1 and 2). A VCL is placed between the plasterboard and the...

Open the catalog to page 7
NyRock® Rainscreen 032 - 8

NyRock RainScreen 032 For use on steel frame or timber frame with a brick outer leaf. • The slabs should be close-butted at all vertical and horizontal joints, and at corners. The horizontal joints of the slabs should be staggered, in accordance with good practice. Slabs should be carefully cut to fit around any protrusions into the cavity. A VCL is placed between the plasterboard and the frame. A breathable membrane is placed between the sheathing board and the product—see Figure 1. The insulation should be installed to coincide with the frame, with retaining discs used in conjunction with...

Open the catalog to page 8
NyRock® Rainscreen 032 - 9

BUILDING SAFETY AND PRODUCT USE LEGAL NOTICES General safety requirements – Building Safety Act 2022 ROCKWOOL Limited is committed to supporting specifiers, resellers and users of ROCKWOOL products for the full life cycle of the product to comply with the obligations and responsibilities set out in the Building Safety Act 2022. With regard to the general safety requirements of the Act, ROCKWOOL Limited cannot control or foresee every situation where its products might be used. We therefore strongly advise that specifiers, resellers and users contact us where use of ROCKWOOL products is...

Open the catalog to page 9

All ROCKWOOL catalogs and technical brochures

  1. Fire Duct

    5 Pages

  2. CAVITY

    12 Pages

  3. firepro-book

    109 Pages

  4. CLADDING ROLL

    12 Pages

  5. Twinroll

    8 Pages

  6. FLEXI®

    20 Pages

  7. ROCKFRAME

    4 Pages

  8. Rockwool vrb

    3 Pages

  9. ROCKPRIME®

    2 Pages

  10. RECYCLING

    4 Pages

  11. EDC

    8 Pages

  12. CORE RANGE

    24 Pages

  13. CORROSION

    20 Pages