Catalog excerpts
Core Range R0CKW00L FLEXI®, Cavity TCB, ROCKFLOOR®, Fire Barrier and Rollbatt 600 & 400 July 2009 Fifth Edition
Open the catalog to page 1Intro Welcome to the ROCKWOOL® Core Range: 6 products for all major applications The edge for performance We’ve harnessed the awesome power of nature to bring you the exceptional performance of our unique insulation. ROCKWOOL® is made from molten volcanic rock to bring you naturally efficient energy saving, unbeatable sound proofing and a level of fire safety that no other general insulation can match. Walls, Partitions & Floors. Unlike other insulation, ROCKWOOL® is suitable for acoustic, fire and thermal applications. The key to ROCKWOOL® is its flexibility. There are products in the core...
Open the catalog to page 2Superb fit - superior performance ROCKWOOL FLEXI® fits perfectly every time - wherever you use it delivering all-round superior insulation performance: Thermally effective Providing a perfect friction fit against frames, joists and studs, ROCKWOOL FLEXI® delivers high levels of insulation, minimising cold bridging through the frame Superior sound performance Snug fit against frames, studs and joists eliminates gaps Environment ROCKWOOL® insulation relies on entrapped air for its thermal properties; air is not a VOC and it does not have Global Warming Potential (GWP) or Ozone Depleting...
Open the catalog to page 3ROCKWOOL FLEXI® ROCKWOOL FLEXI®- the ingenious volcanic rock slab with the patented flexi-edge that makes installation The flexi-edge is unique and ensures a perfect fit every time, within floor joists, between rafters, metal and timber studs and metal and timber frame buildings. Unlike rigid insulants, ROCKWOOL FLEXI® will hold itself within the stud centres required, first time, every time. Timber expands and contracts, ROCKWOOL FLEXI® can be fitted between damp timber and will expand into the wider space created when the timber has dried out and shrunk back. Other rigid or very flimsy...
Open the catalog to page 4Suspended Timber Joisted Floor The P/A on the next page indicates the ROCKWOOL FLEXI® thickness required to achieve an elemental Full Fill Rafter with Breather Membrane ROCKWOOL FLEXI® thickness (mm) 38mm Rafters 0 600mm Centres* 38mm Rafters 0 400mm Centres*
Open the catalog to page 5Flexi-edge makes installation so easy Simply squeeze the patented ROCKWOOL FLEXI® into the space required and let go, it will spring back for a perfect fit every time. Even if the studs are not plumb ROCKWOOL FLEXI® will fit the space between the studs perfectly without the need for cutting or waste. Timber Joist Domestic Internal Floor To meet part E2 Rw 40 dB ROCKWOOL® guidance specification Standard 18mm t&g flooring chipboard, mass per unit area 12.4kg/m² Timber joists @ 400mm ctrs 100mm thick ROCKWOOL FLEXI® between joists Single layer of 12.5mm plasterboard ceiling mass per unit area...
Open the catalog to page 6Size and usage information Size (Length & Width) 1200 x 600mm Size (Length & Width) 1200 x 400mm One layer of 12.5mm plasterboard both sides (Mass 8Kg/m2) 38 x 75mm timber studs at 600mm centres 50 X 600mm wide ROCKWOOL FLEXI® 12.5 plasterboard both sides (Mass 11Kg/m2) ROCKWOOL FLEXI® Application for timber stud walls Rw 40dB Acoustic metal studs Rw 41dB
Open the catalog to page 7Proven over 40 years Easier to cut, no slump, no gaps, water resistant and fits tightly to internal block work ROCKWOOL® Cavity showing ROCKWOOL® edge and floor insulation
Open the catalog to page 8Cavity Fully filled and fully proven ROCKWOOL® Cavity provides a completely reliable and cost effective method of insulating new masonry cavity walls. The lightweight insulation batts considerably reduce heat loss without permitting water transmission from the outer to the inner leaf. The risk of condensation is also reduced and intermittent heating systems will be more effective. Advantages BBA certified for all exposure zones Acts as a cavity barrier Water repellent Excellent thermal and fire insulation Superior fit against blockwork Installation guide The installation of the batts should...
Open the catalog to page 9The as-built cavity width must not exceed the following dimensions: Dimensions Size (Length & Width) 1200mm x 455mm m ²/pack Nominal Batt Maximum as-built clear Prevent mortar dropping onto slabs or wall ties
Open the catalog to page 10Masonry Full Fill Cavity Wall 102mm facing brick outerskin, ROCKWOOL® Cavity Full Fill, internal concrete block 100mm, plasterboard Internal BlockBlock'K' Dense 1.130 W/mk Medium/Light 0.190 W/mk Aircrete 0.110 W/mk Valuelnsulation Thickness 'U'-value 'U'-value 'U'-value Building regulations requirements Part 'L 2006 for England and Wales The lightweight insulation batts considerably reduce heat loss without permitting water transmission from the outer to the inner leaf.
Open the catalog to page 11Fire safety for cavities range ROCKWOOL® TCB Cavity Barrier is a polyethylene sleeved ROCKWOOL® strip engineered to provide fire safety for timber frames, metal frames and traditional masonry cavities. Standard TCB Cavity Barrier comprises a strip of ROCKWOOL® inserted into a translucent red polyethylene sleeve incorporating two flanges designed ROCKWOOL® TCB's have been fire tested to 60 minutes integrity and 30 minutes insulation and is used to provide a half hour cavity barrier as defined in Section 33 of the Building Regulations Technical Guidance ■ Reduced installation time ■ Meets...
Open the catalog to page 12The ROCKWOOL® TCB Cavity Barrier Compresses to a tight fit, is easy to install and maintenance free
Open the catalog to page 13Fixing of the TCB Cavity Barrier to the inner leaf is carried out only at the flanges using non-corrosive staples or clout nails. These fixings should be located at maximum 150mm centres in both horizontal and vertical applications. Joints between TCB's must be closely butted. At door and window jambs, the horizontal barrier should overlap the vertical barrier to ensure a close butted joint is maintained between both barriers. clout nails TCB at door or window jamb ROCKWOOL® Roll cavity closer partial fill TCB used as cavity closer
Open the catalog to page 14ROCKFLOOR® Thermal & acoustic floor solutions Acoustic ROCKFLOOR® is a tissue faced high compressive strength product designed as a mono density, rebated slab suitable for acoustic treatments of intermediate floors. Thermal ROCKFLOOR® is a unique dual density, high compressive strength ROCKWOOL® slab designed specifically for use as thermal insulation for floors. Advantages Excellent acoustic and thermal properties High compressive resistance Easy handling and fitting Fully tested Minimises thermal and acoustic bridging thicknesses from 25 mm to 100 mm. 30 mm and 40 mm thick ROCKFLOOR®...
Open the catalog to page 15All ROCKWOOL catalogs and technical brochures
-
NyRock® Rainscreen 032
10 Pages
-
OSCB Contractors’ Guide
16 Pages
-
Fire Duct
5 Pages
-
NyRock® Frame Slab 032
7 Pages
-
CAVITY
12 Pages
-
hardrock-ub34-datasheet
5 Pages
-
ductslab-ductwrap
12 Pages
-
tcb--pcwb-datasheet
12 Pages
-
RAINSCREEN DUO SLAB®
14 Pages
-
intumescent-pillows-ce-datasheet
12 Pages
-
firepro-book
109 Pages
-
Product Application Guide
37 Pages
-
SP FIRESTOP VRB
8 Pages
-
CLADDING ROLL
12 Pages
-
FIRE BARRIER SYSTEM
20 Pages
-
Twinroll
8 Pages
-
FLEXI®
20 Pages
-
BEAMCLAD® System
16 Pages
-
Ablative Coated Batt
8 Pages
-
Fire Duct Systems
16 Pages
-
ROCKFRAME
4 Pages
-
SANDWICH PANELS
6 Pages
-
Redart silicone
5 Pages
-
Rockwool techwrap & techtube
4 Pages
-
DUCTSLAB AND DUCTWRAP
8 Pages
-
Rockwool vrb
3 Pages
-
ROCKPRIME®
2 Pages
-
THE SMOKE REPORT
20 Pages
-
*NEW* ROCKWOOL TRADE RANGE
2 Pages
-
FLAT ROOF APPLICATION GUIDE
32 Pages
-
HARDROCK® MULTI-FIX TAPERED
1 Pages
-
SOCIAL HOUSING BROCHURE
7 Pages
-
FIREPRO® SOFTSEAL
8 Pages
-
SAFER BUILDINGS
12 Pages
-
HARDROCK® MULTI-FIX SOLUTION
16 Pages
-
BRICKSHIELD®
6 Pages
-
FIREPRO® DUCT WORK
4 Pages
-
PART L PIPES AND DUCTS
12 Pages
-
FIREPRO® GLUE
4 Pages
-
ENERGYSAVER®
8 Pages
-
BRICK EFFECT RENDER
3 Pages
-
ACOUSTIC MEMBRANE
5 Pages
-
ACOUSTIC INTUMESCENT SEALANT
4 Pages
-
ACOUSTIC INFILL
4 Pages
-
RECYCLING
4 Pages
-
EDC
8 Pages
-
ENERGYSAVER®
2 Pages
-
CORROSION
20 Pages
-
building_and_construction
20 Pages
-
hardrockdualdensitydatasheet
16 Pages
-
acoustic party wall
4 Pages
-
firepro book final
88 Pages