CW 50
2Pages

{{requestButtons}}

Catalog excerpts

CW 50 - 1

The Inward Opening Window, also known as the hidden vent is a structural silicone glazing solution which can be applied in standard curtain wall façade or in structurally clamped façade. It’s main advantage is that the exterior doesn’t differ from a xed glazing panel in the façade. Therefore it doesn’t affect the even façade geometry. Water tightness is assured by the use of a central gasket. This system uses a half mullion so it has a minimal visible width from the inside. Flush Roof Vent: The Flush Roof Vent has been developed to perfectly blend into the buildings’ outer shell without causing any disruption to the surface and can have inclination angles of 5° up to 80°. Thus not limiting but on the contrary stimulating architectural creativity. The superior HI variant assures an increased insulation by using additional insulation gaskets and longer insulation strips. The possibility to integrate 52 mm glass in the HI version further enhances thermal efciency. A motor-operated version is especially convenient within Médiacité - Liège (Architects : Ron Arad Associates - Jaspers & Eyers) TUTI Hidden Vent building management systems or in roof windows in hard-to-reach places. CW 50 Maximum natural light PERFORMANCES ENERGY Thermal insulation (1) EN 13947 Uf = value as down to 0,8 W/m²K, depending on the prole combination COMFORT Acoustic performance (2) EN ISO 140-3; EN ISO 717-1 RW (C;Ctr) = 33 (-1; -3) dB / 60 (-2; -6) dB, depending on glazing or panel type Air tightness (3) EN 12153, EN 12152 A1 (150 Pa) A2 (300 Pa) A3 (450 Pa) A4 (600 Pa) AE 1200 (1200 Pa) Water tightness (4) EN 12155, EN 12154 R4 (150 Pa) R5 (300 Pa) R6 (450 Pa) R7 (600 Pa) RE 1200 (1200 Pa) Wind load resistance, max. test pressure (5) EN 12179, EN 13116 Resistance against impact EN 14019 2000 Pa I3/E5 I5/E5 This table shows classes and values of performances, which can be achieved for specic congurations and opening types. (1) The Uf-value measures the heat ow. The lower the Uf-value, the better the thermal insulation of the frame. (2) The sound reduction index (Rw) measures the capacity of the sound reduction performance of the frame. (3) The air tightness test measures the volume of air that would pass through a closed window at a certain air pressure. (4) The water tightness testing involves applying a uniform water spray at increasing air pressure until water penetrates the window. (5) The wind load resistance is a measure of the prole’s structural strength and is tested by applying increasing levels of air pressure to simulate the wind force. CW 50 is a curtain wall façade and roof system that offers unlimited creative freedom and allows maximum entrance of light into the building. The system offers 11 individual styles with various outside appearances. Any combination of vertical and inclined planes are possible together with the integration of different types of vents. The extensive range offers technical solutions for the different performance requirements of a façade such as reproof and high insulating solutions. REYNAERS ALUMINIUM NV/SA • www.reynaers.com • info@reynaers.com 01/2012 – 0H0.40C2.00 – Publisher Responsible at Law: Els Fonteyne, Oude Liersebaan 266, B-2570 Duffel

Open the catalog to page 1
CW 50 - 2

Reynaers curtain walls are designed to meet the requirements of contemporary architecture. In extension TECHNICAL CHARACTERISTICS TECHNICAL CHARACTERISTICS to that, additional more practical features to these curtain walls, like different opening types, should not disrupt the global design of the building. Top Hung Window – THW: The Top Hung Window allows integrating big opening elements with big opening spans, which can be operated Style variants manually or automatically. Choosing for a glazing bead or in structural silicone glazing (SSG) can stress CW 50 CW 50 SWISS SOLUTION CW 50-FP CW...

Open the catalog to page 2

All Reynaers Aluminium catalogs and technical brochures

  1. reference book

    63 Pages

  2. Reynaers

    12 Pages

  3. SlimPatio 68

    2 Pages

  4. Hi-Finity

    4 Pages

  5. SlimLine 68

    2 Pages

  6. SlimLine 38

    2 Pages

  7. Masterline

    5 Pages

  8. Reynascreen

    2 Pages

  9. BS 100/30/20

    2 Pages

  10. CS 68

    2 Pages

  11. ES 50

    2 Pages

  12. CS 104

    2 Pages

  13. BIM

    4 Pages

  14. CS 86-HI

    2 Pages

  15. CS 77

    2 Pages

  16. Report 11

    68 Pages

  17. REFERENCE BOOK

    63 Pages

  18. CS 86 HI

    2 Pages

  19. Report 13

    68 Pages

  20. Report 12

    68 Pages

  21. Ventalis

    4 Pages

Archived catalogs

  1. REFERENCE BOOK

    57 Pages

  2. Vision 50

    2 Pages

  3. ES 45Pa

    2 Pages

  4. Eco system

    2 Pages

  5. BS

    2 Pages

  6. CP 130

    4 Pages

  7. CF 77-SL

    4 Pages

  8. CF 77

    4 Pages

  9. RB 10

    2 Pages

  10. Punch Tool

    2 Pages

  11. Report 10

    68 Pages

  12. Report 9

    68 Pages

  13. CS104

    2 Pages

  14. CP 155

    4 Pages

  15. RW 100

    8 Pages

  16. Optima

    4 Pages

  17. CS 104

    2 Pages

  18. CS 59-Pa

    2 Pages

  19. CS 59

    2 Pages

  20. CS 38-SL

    2 Pages

  21. CS 24-SL

    2 Pages

  22. CS 77-BP

    2 Pages

  23. CS 77

    2 Pages

  24. CS 68-FP

    2 Pages

  25. BS 40

    2 Pages

  26. TP 110

    2 Pages

  27. TLS 110

    2 Pages

  28. RW 105

    8 Pages

  29. CP 96

    4 Pages

  30. CP 50

    2 Pages

  31. CP 45 PA

    2 Pages

  32. CW 86

    4 Pages

  33. CW 65 EF-HI

    2 Pages

  34. CW 60 Solar

    2 Pages

  35. CW 60

    2 Pages

  36. TR 200

    2 Pages

  37. PR 100

    2 Pages

  38. Reynascreen

    2 Pages

  39. GP 51

    2 Pages

  40. CR 120

    2 Pages

  41. Cintro

    2 Pages

  42. Mosquito

    2 Pages

  43. Report 8

    68 Pages

  44. Report 7

    70 Pages

  45. Reference Book

    100 Pages

  46. CW 60- DRL

    2 Pages