CS 104
2Pages

{{requestButtons}}

Catalog excerpts

CS 104 - 1

Architect Mark Van Acker Solution for passive construction With the CS 104 window and door system, Reynaers achieves unparalleled insulation values for aluminium profiles in the building industry, introducing a solution for passive buildings. The high insulation levels, down to an Uf-value of 0.88 W/m²K, are achieved by the use of a patented insulation technology which contains a special foam, firmly fixed in the chamber of the insulation strip so that no extra manipulation is required when handling, processing and composing the window and door. A new set of specifically developed gaskets also assures the high level of the wind and water tightness of the system. After insulation, air tightness is the most important factor determining the energy efficiency of a window or door. In addition to the high insulation values, CS 104 offers extremely high performance when it comes to water tightness. With values up to 900 Pa for windows and 300 Pa for doors, the system is suitable for extreme conditions such as coastal areas, and can be applied at extreme heights. The increased built-in depth of the profiles (the vent is 104mm deep) contributes furthermore to their strength and stability. This gives architects and builders the design benefits of large, expansive surfaces of triple glazing resulting in innovative, energy-efficient and yet sustainable solutions.

Open the catalog to page 1
CS 104 - 2

TECHNICAL CHARACTERISTICS MIX Paper from responsible sources FSC* C007370 (1) The Uf-value measures the heat flow. The lower the Uf-value, the better the thermal insulation of the frame. (2) The air tightness test measures the volume of air that would pass through a closed window at a certain air pressure. (3) The water tightness testing involves applying a uniform water spray at increasing air pressure until water penetrates the window. (4) The wind load resistance is a measure of the profile's structural strength and is tested by applying increasing levels of air pressure to simulate the...

Open the catalog to page 2

All Reynaers Aluminium catalogs and technical brochures

  1. Reynaers

    12 Pages

  2. SlimPatio 68

    2 Pages

  3. Hi-Finity

    4 Pages

  4. SlimLine 68

    2 Pages

  5. SlimLine 38

    2 Pages

  6. Masterline

    5 Pages

  7. Reynascreen

    2 Pages

  8. BS 100/30/20

    2 Pages

  9. CS 68

    2 Pages

  10. ES 50

    2 Pages

  11. BIM

    4 Pages

  12. CS 86-HI

    2 Pages

  13. CS 77

    2 Pages

  14. Report 11

    68 Pages

  15. CS 86 HI

    2 Pages

  16. Report 13

    68 Pages

  17. Report 12

    68 Pages

  18. Ventalis

    4 Pages

Archived catalogs

  1. Vision 50

    2 Pages

  2. ES 45Pa

    2 Pages

  3. Eco system

    2 Pages

  4. BS

    2 Pages

  5. CP 130

    4 Pages

  6. CF 77-SL

    4 Pages

  7. CF 77

    4 Pages

  8. CW 50

    2 Pages

  9. RB 10

    2 Pages

  10. Punch Tool

    2 Pages

  11. Report 10

    68 Pages

  12. Report 9

    68 Pages

  13. CS104

    2 Pages

  14. CP 155

    4 Pages

  15. RW 100

    8 Pages

  16. Optima

    4 Pages

  17. CS 104

    2 Pages

  18. CS 59-Pa

    2 Pages

  19. CS 59

    2 Pages

  20. CS 38-SL

    2 Pages

  21. CS 24-SL

    2 Pages

  22. CS 77-BP

    2 Pages

  23. CS 77

    2 Pages

  24. CS 68-FP

    2 Pages

  25. BS 40

    2 Pages

  26. TP 110

    2 Pages

  27. TLS 110

    2 Pages

  28. RW 105

    8 Pages

  29. CP 96

    4 Pages

  30. CP 50

    2 Pages

  31. CP 45 PA

    2 Pages

  32. CW 86

    4 Pages

  33. CW 65 EF-HI

    2 Pages

  34. CW 60 Solar

    2 Pages

  35. CW 60

    2 Pages

  36. TR 200

    2 Pages

  37. PR 100

    2 Pages

  38. Reynascreen

    2 Pages

  39. GP 51

    2 Pages

  40. CR 120

    2 Pages

  41. Cintro

    2 Pages

  42. Mosquito

    2 Pages

  43. Report 8

    68 Pages

  44. Report 7

    70 Pages

  45. Reference Book

    100 Pages

  46. CW 60- DRL

    2 Pages