Catalog excerpts
■ STATIONARY HOT AIR HEATING SYSTEMSRapid heat, adapted to your needs Stationary heaters Wall-mounted heaters Universal heaters Hot water heaters Ceiling ventilation units Ceiling heating systems Ceiling fans Exhaust gas systems
Open the catalog to page 1REMKO THE SYSTEM PROVIDER About REMKO REMKO is a globally active company for heating and air-conditioning technology. Our highly efficient product range comprises hot air heating systems, dehumidifiers, air-conditioning systems and air-conditioners, as well as future-looking heat pumps. Since 1976, we have grown consistently with the requirements of our customers as a medium-sized company. Extensive experience, innovative product development and reliable service are our strengths when it comes to needs-based solutions in the areas of heating, air-conditioning and dehumidifying. With our...
Open the catalog to page 2CONTENTS Page Stationary hot air heating systems Series 5 Rapid heat, adapted to your needs 6-11 Wall-mounted heating systems GPS with two-stage gas burner 12-17 Wall-mounted calorific value heaters GPC with modulating gas burner in a condensing design 18-21 Universal heaters VRS E For oil and gas combustion 22-23 Hot water heaters PWN H in low-temperature design 24-27 Warm water heaters PWW in a modular system adapted for planning needs 28-29 Ceiling ventilation units PWL H in comfort design 30-31 Ceiling heating systems WPS Differential temperature controller ATR Stainless steel,...
Open the catalog to page 3STATIONARY HOT AIR HEATING SYSTEMS Rapid heat, adapted to your needs Tailored heating of halls Stationary hot air heaters are mainly used in industrial halls for continuous operation. They are installed to walls, ceilings or floors and can be adapted to the specific circumstances of the installation site according to the modular principle. Hot air heaters, however, can also be connected to an existing hot air heating plant. The heat can be directly wherever needed in a targeted manner using air control fins. Due to the easy assembly of the units, the required heating capacity can be adapted...
Open the catalog to page 5REMKO GPS SERIES Hall heating with high energy efficiency The REMKO series is characterised by their compact dimensions, flexible application possibilities, and particularly by their microprocessor controlled gas burner technology. A total of five unit sizes with a heating capacity from 13.0 to 73.5 kW is available. The units are suitable for both wall and ceiling mounting. A variety of exhaust gas and fresh air versions rounds out the flexible installation possibility of this series of units. Through the use of the two-stage gas burner technology, a high energy efficiency is achieved with...
Open the catalog to page 6Technical data Unit type * * The gas connection must be performed by a licensed installer Calorific value H i related to dry standard test gas at 15 °C and 1,013.25 mbar Natural gas H G 20 = 9.45 kWh/m3 Liquid gas G 30 = 12.68 kWh/kg Erdgas L G 25 = 8.13 kWh/mfi Liquid gas G 31 = 12.87 kWh/kg Switchgear and control units Cabled remote control KF-30 surface mounting, type of protection IP20, electrical remote unlocking mechanism, Heat/Ventilate selector switch, including 3.5 m connecting cable Temperature control RR-30 surface mounting, type of protection IP20, selector switch for...
Open the catalog to page 7Outside wall installation Unit installation, including the exhaust gas and fresh air versions, takes place according to classifications C13, C33, C43, C53, C63, and B23 of DVGW-TRGI 2008. The gas connection must be performed by a licensed fitter. Before the installation of the exhaust gas duct through the outside wall, the district heating inspector must be consulted. Chimney duct through wall with burner fresh air supply Dimensions of Unit type
Open the catalog to page 8Chimney duct through wall LAS balanced flue system through the wall with burner fresh air supply Note Please observe the following pipe diameters during planning. AW1 0 80 AW1 0 100 AW2 0 80 AW2 0 100 Plan a wall opening with 5 mm clearance 1 After the determination of the chimney duct, the pressure loss for the respective unit must be established. When using chimney bends, the pressure losses must especially be taken into account. 2) Specification of the maximum fresh air and exhaust gas length. For GPS 55/75 in design AW1, longer variants are also available on request. CE certificate no....
Open the catalog to page 9LAS balanced flue system through roof with burner fresh air supply, WSA 81 series, single-walled aluminium, complete, comprising: 1 Pos. 6 1 T-connection, 90° Pos. 7 1 cleaning component with condensate drain Pos. 8 1 unit roof penetration, LAS sys tem with burner, fresh air supply, including rain hood, overall length 1850 mm Pos. 16 1 exhaust gas pipe with conden sate drain, vertical, length 185 mm, including adapter 032 Pos. 18 1 connection port with test nipple Pos. 19 1 exhaust gas or fresh air pipe, Chimney duct through roof, WSA 82 series, single-walled aluminium chimney, complete,...
Open the catalog to page 10Exhaust gas duct through roof Unit type * The slanted/flat roof penetration must be ordered as well if required Chimney height Maximum additional pipe length 1 Specification of the maximum fresh air and exhaust gas length. 2) GPS 55/75: longer designs WSA 101 and WSA 102 on request
Open the catalog to page 11Wall-mounted calorific value heating systems with modulating gas burner in a condensing design REMKO GPC SERIES Hall heating with the highest energy efficiency The REMKO series is characterised by their compact dimensions, flexible application possibilities, and particularly by their microprocessor controlled gas burner technology. A total of four unit sizes with a heating capacity from 4.7 to 82.0 kW is available. The units are suitable for both wall and ceiling mounting. A variety of exhaust gas and fresh air versions rounds out the flexible installation possibility of this series of...
Open the catalog to page 12Technical data Unit type * * The gas connection must be implemented by a licensed installer ** The exhaust gas and fresh air diameter is achieved by an adapter that is included with the standard version
Open the catalog to page 13Outside wall installation Unit installation, including the exhaust gas and fresh air versions, takes place according to classifications C13, C33, C43, C53, C63, and B23 of DVGW-TRGI 2008. The gas connection must be performed by a licensed fitter. Before the installation of the exhaust gas duct through the outside wall, the district heating inspector must be consulted. Chimney duct through wall with burner fresh air supply Dimensions of Unit type The exhaust gas and fresh air diameter is achieved by an adapter that is included with the standard version.
Open the catalog to page 14All REMKO GmbH & Co. KG catalogs and technical brochures
-
Brine-Water Heatpumps
28 Pages
-
Pool dehumidifiers
8 Pages
-
Professional dehumidifiers
4 Pages
-
Mobile dehumidifiers
8 Pages
-
Monobloc heatpump
28 Pages
-
ArtStyle Heatpumps
40 Pages
-
Air-Air heatpumps
8 Pages
-
Comfort Air-Conditioners
32 Pages
-
MOBILE HOT AIR HEATING SYSTEMS
28 Pages
-
Local Air Conditioners
12 Pages
-
INDUSTRIAL VACUUM CLEANERS
4 Pages
-
HIGH-PERFORMANCE FANS
8 Pages
Archived catalogs
-
COMFORT AIR-CONDITIONERS_2012
24 Pages
-
AIR-CONDITIONERS 2012-13
16 Pages
-
Pool dehumidifiers 2010-2011
8 Pages
-
Dehumidifier 2010-11
8 Pages
-
Inverter Heat Pumps 2010-11
28 Pages
-
Comfort air-conditioners 2010-11
28 Pages
-
Air conditioner
12 Pages