Mobile Warm Air Heating Systems 2010-2011
16Pages

{{requestButtons}}

Catalog excerpts

Mobile Warm Air Heating Systems 2010-2011 - 1

MOBILE HOT AIR HEATING SYSTEMS Mobile Heaters Heating Centers Edition 2010/2011 Quality with system

Open the catalog to page 1
Mobile Warm Air Heating Systems 2010-2011 - 2

REMKO – THE CUSTOMER ORIENTATED SYSTEM PROVIDER FOR THE WHOLE YEAR AIR-CONDITIONING Air-conditioners Portable air-conditioners Wall units - cassettes Chilled water systems Chillersr HEATING Warm air heating systems Mobile and stationary heaters Oil - gas - electric NEW ENERGIES Heat-pumps Inverter heat-pumps Heat pump packages DEHUMIDIFICATION Dehumidifier Mobile dehumidifiers Professionally dehumidifiers Pool dehumidifiers Quality with system 2

Open the catalog to page 2
Mobile Warm Air Heating Systems 2010-2011 - 3

Product overviewMobile hot air heating units Page Series 4-15 Mobile Automatic Heater 4 Electric heaters ELT 5 Electric infrared radiator EST 6-7 Propane gas heaters PGM/PGT 8-9 Oil heaters with built-in oil burner and tank DZH/ATK 10-12 Oil/gas heaters with separate burner CLK 13 Accessories 14-15 Heating centers Heating centers with separate burner HTL 3

Open the catalog to page 3
Mobile Warm Air Heating Systems 2010-2011 - 4

4 Technical data Series ELT 2-1 ELT 3-2 ELT 9-6 ELT 10-6 ELT 18-9 ELT 18-S* Max. nominal heat load kW 2,2 3,2 9,0 10,5 18 18 Nominal heat output kW 2,2 3,2 9,0 10,5 18 18 Switchable heat output kW 1 x 2,2 1 x 3,2 2 x 4,5 3 x 3,5 3 x 6 3 x 6 Air capacity m³/h 250 350 600 750 1.000 1.600 Voltage supply V/Hz 230/1~/50 230/1~/50 400/3~N/50 400/3~N/50 400/3~N/50 400/3~N/50 Max. nominal current A 9,5 13,90 13,2 14,90 27,50 27,80 Room thermostat eingebaut Zubehör eingebaut Zubehör Zubehör Zubehör Length mm 300 400 510 675 740 750 Width mm 200 200 300 300 335 335 Height mm 315 335 455 455 500 500...

Open the catalog to page 4
Mobile Warm Air Heating Systems 2010-2011 - 5

5 Technical data Series EST Nominal heating capacity kW 2,0 Nominal heat output kW 2,0 Max. nominal current A 9,1 Voltage supply V/Hz 230/1~/50 Depth mm 305 Width mm 305 Height mm 905 Weight kg 10 Series color white EDP no. 112150 REMKO ELT 18-S REMKO EST Hot air tube operation permits any kind of heat distribution. The ELT 18-S electric heater is especially developed for the connection of hot air tubes. This means this device combines all product advantage of the REMKO ELT series with the application possibilities of hot air tube operation. The hot air can be easily conducted to where it...

Open the catalog to page 5
Mobile Warm Air Heating Systems 2010-2011 - 6

6 REMKO PGM 30 REMKO PGT 60 REMKO PGT 100 PROPANE GAS HEATERS PGM and PGT series High performance and versatile ¡ Servicing and maintenance friendly ¡ Optional, fully automatic control of the PGT series via room thermostat ¡ Multi-cylinder set for the connection of several gas cylinders ¡ Variable power control ¡ Immediately ready for operation ¡ 100% efficiency ¡ Easy to transport ¡ Heat-insulating, double housing made of zinc-coated sheet steel, powder coated REMKO PGM REMKO PGT Fast spot heating for indoor and outdoor use The heaters of the REMKO PGM and PGT series are designed for...

Open the catalog to page 6
Mobile Warm Air Heating Systems 2010-2011 - 7

7 Technical data Series PGM 30 PGM 60 PGT 30 PGT 60 PGT 100 Max. nominal heat load kW 10-26 25-55 10-26 25-55 50-100 Nominal heat output kW 10-26 25-55 10-26 25-55 50-100 Air capacity m³/h 800 1.450 800 1.450 3.600 Fuel/gas type Liquid gas, Category 13 Device connecting pressure bar 1,5 1,5 1,5 1,5 1,5 Device connected load kg/h 0,78-2,0 1,95-4,27 0,78-2,0 1,95-4,27 3,9-7,8 Voltage supply V/Hz 230/1~/50 Length mm 450 650 450 650 1.060 Width mm 260 320 260 320 435 Height mm 410 510 410 510 620 Weight kg 12 20 12 20 47 Power regulation Series Series Series Series Series Thermostatically...

Open the catalog to page 7
Mobile Warm Air Heating Systems 2010-2011 - 8

8 Series DZH 20 DZH 30 DZH 50 DZH 90 Max. nominal heat load kW 18 30 45 93 Nominal heat output kW 18 30 45 93 Execution portable portable portable portable Air capacity m³/h 350 450 1.400 1.800 Fuel EL heating oil/diesel Max. fuel consumption l/h 1,79 2,98 4,46 9,38 Tank volume Liter 17 40 62 105 Voltage supply V/Hz 230/1~/50 Length mm 800 1050 1.090 1.400 Width mm 300 500 500 655 Height mm 520 615 740 890 Weight kg 21 37 43 84 EDP no. 116200 116300 116500 116900 Other accessories Moistureproof room thermostat, Type RT-5, ready for plug assembly, low switching difference, type of protection...

Open the catalog to page 8
Mobile Warm Air Heating Systems 2010-2011 - 9

9 Series ATK 25 Max. nominal heat load kW 25 Nominal heat output kW 22,5 Air capacity m³/h 1.080 Fuel EL heating oil/diesel Max. fuel consumption l/h 2,4 Tank volume Liter 40 Tank heater built-in Voltage supply V/Hz 230/1~/50 Length mm 1.265 Width mm 470 Height mm 685 Exhaust pipe adapter Ø mm 150 Weight kg 68 EDP no. 120850 Other accessories Moistureproof room thermostat, Type RT-5, ready for plug assembly, low switching difference, type of protection IP 54, incl. 10 m moistureproof room cable, connecting plug, and protective device made of lacquered sheet steel 1011250 Special exhaust...

Open the catalog to page 9
Mobile Warm Air Heating Systems 2010-2011 - 10

10 REMKO CLK 50 OIL/GAS HEATERS CLK series with separate burner REMKO CLK Versatile application possibilities for construction site heating In case of sudden cold or undelayable, scheduled work, the heaters of the CLK series bring the necessary heat to wherever it is desired. This makes construction independent of the weather because construction on a deadline means that work may be performed during the cold season. Structures, materials, and workstations must then be protected. Ideal for heating workshops, exhibition rooms, and halls The mobile devices must be in place only during the...

Open the catalog to page 10
Mobile Warm Air Heating Systems 2010-2011 - 11

11 REMKO CLK 150 Series CLK 30 CLK 50 CLK 70 CLK 120 CLK 150 Max. nominal heat load kW 29 46 68 121 144 Nominal heat output kW 26,5 42 62 110 131 Air capacity m³/h 1.760 2.780 4.920 7.350 8.920 Fuel EL heating oil according to DIN 51603 or diesel fuel Max. fuel consumption l/h 2,85 4,5 6,6 11,8 14,0 Max. exhaust gas loss % 9 9 9 9 9 Voltage supply V/Hz 230/1~/50 230/1~/50 230/1~/50 230/1~/50 230/1~/50 Max. nominal current A 1,8 2,0 4,0 6,0 8,8 Max. power consumption W 370 420 860 1.300 1.900 Air outlet Ø mm 300 300 400 500 500 Exhause gas connection Ø mm 150 150 150 200 200 Total length mm...

Open the catalog to page 11
Mobile Warm Air Heating Systems 2010-2011 - 12

12 Series CLK 30 CLK 50 CLK 70 CLK 120 CLK 150 Max. nominal heat load kW 29 46 68 121 144 Nominal heat output kW 26,5 42 62 110 131 Air capacity m³/h 1760 2780 4920 7350 8920 Heaters with oil burner * Oil preheating and oil-reservoir fitting EDP no. 121700 123700 125700 127700 130700 Heaters with propane gas burner * ** EDP no. 121600 123600 125600 127600 130600 Heaters without burner EDP no. 121500 123500 125500 127500 130500 Other accessories Moistureproof room thermostat, Type RT-5, ready for plug assembly, type of protection IP 54 1011250 1011250 1011250 1011250 1011250 Oil-reservoir...

Open the catalog to page 12