Quality with system INVERTER HEAT PUMPS Cosy heating in winter Comfortable air-conditioning in the summer Independently from oil and gas Energy costs economize by - Inverter Inverter Heat pumps with certified performance numbers by the german technical control board (TÜV)

Open the catalog to page 1
Inverter Heat Pumps 2010-11 - 2

2 electrical drive energy * 25%* Heat 75% free solar energy from the air In contrast to other heating systems, the acquisition costs for a heat pump in new or older buildings pays off relatively quick. ¡ Considerably lower consumption and operating costs ¡ Marginal maintenance costs ¡ No costs for chimney and chimney sweep ¡ No costs for a tank ¡ No costs for a tank room The advantages of a heat pump are obvious New dimensions in terms of independence The solar energy stored in the air is an inexhaustible source of emission-free power. Heat pumps take up to 75% of the energy from the air...

Open the catalog to page 2
Inverter Heat Pumps 2010-11 - 3

-INVERTER 3 Highly efficient and energy saving The -INVERTER costs economizes The REMKO Inverter heat pump represents a decision for a technically most progressive solution. Modern inverter technology makes it possible. This pioneering technology automatically adapts the condenser speed variably to the precise cooling or heating requirement. This exact and gentle regulation enables a particularly energy saving, efficient operation with a high seasonal performance factor in comparison to non-inverter systems. In summery: In the event of increased demand, the heat pump works more intensively,...

Open the catalog to page 3
Inverter Heat Pumps 2010-11 - 4

4 Evaporation Liquefaction Condensing Decompression Functional diagram heating inverter heat pump Heat pump outdoor unit Outdoor area Heat pump indoor unit Indoor area THE FUNCTION OF THE INVERTER HEAT PUMP Heat pump technology The technology of the heat pump is similar to that of a refrigerator - only the principle is reversed. The heat extracted from the air is brought up to a higher temperature level in a refrigerant circuit and is then transfered to the indoor unit. Function of outdoor unit The outdoor unit takes energy from the air. This energy is brought up to a higher temperature...

Open the catalog to page 4
Inverter Heat Pumps 2010-11 - 5

5 Indoor unit in wall-mounted design CMF series A compact solution in combination with solar plants and/or other heat generators (bivalent operation). Indoor unit in standard design with storage tank (150 l) for hydraulic decoupling of the volumetric flow CMT series An ideal solution to use the heat pump as a single heat generator with integrated buffer tank and electrical support heater (mono energetic operation). Heat pumps in new buildings. Independent of oil and gas Heat pumps for modernisation of existing buildings. Combination with existing heating appliances Heat pumps in office...

Open the catalog to page 5
Inverter Heat Pumps 2010-11 - 6

6 Modern radiators Heat pump outdoor unitType CMF/CMT Heat pump indoor unit Typ CMF Heating unit Storage system Solar plant 3 2 1 4 Combination with storage systems The interface and collection point for various energy systems Tanks are offered in various designs and capacities. With connection options for heat pumps, heating appliances, solar plants and water heating, the storage system is the interface and collection point. In addition, the storage system enables hydraulic decoupling of the volumetric flows in complete energy systems. Combination with heating appliances in bivalent...

Open the catalog to page 6
Inverter Heat Pumps 2010-11 - 7

7 Effective water heating AC unit The scheme shows a simplified illustration of the Inverter heat pump functions. Floor heating 5 4 6 Effective water heating If the inverter water pump is also to handle the water heating, you will require an external hot water storage tank. See 3 a trouble-free and reliable water heating system is guaranteed. We recommend a hot water system combined with a solar energy plant. See 1 5 Combination with floor heating – modern radiators and wall-mounted heaters Heat pumps are able to achieve their highest levels of efficiency when combined with floor heating....

Open the catalog to page 7
Inverter Heat Pumps 2010-11 - 8

8 ¡ Modern inverter technology ¡ Heating, cooling and water heating system ¡ Energy source outdoor air operational down to -18° C ¡ Hot water heating up to + 60° C ¡ Fully-automatic, quiet and maintenance-free operation ¡ High level of operational reliability ¡ Low installation efford ¡ Floor-area optimised design Save costs with a modern inverter technology This pioneering inverter technology automatically adapts the condenser speed variably to the precise cooling or heating requirement. This exact and gentle regulation enables a particularly energy saving, efficient operation with a high...

Open the catalog to page 8
Inverter Heat Pumps 2010-11 - 9

9 REMKO CMT series Indoor unit in standard design with storage tank (150 l) Free choice when installing the outdoor units You save a lot of space when installing the outdoor units externally. You can use the basement space for other purposes such as a party room or sauna. Outdoor installation is ideal for buildings without a basement. Integrated storage tank CMT series The storage tank ensures optimised operating times and provides hydraulic decoupling of the volumetric flows for the heat pumps and heating circuit. Outdoor unit CMF/CMF series

Open the catalog to page 9
Inverter Heat Pumps 2010-11 - 10

10 Receiver Transmitter The complete energy management system The heat pump manager handles the complete energy management. The regulator has everything perfectly under control. No matter whether it is dealing with the control of an individual device, an entire system or the regulation of a complex plant. The REMKO heat pump manager is a multitalent. The Multitalent PLUS includes a heat meter for optionally official subsidies claims which might depend on each country’s regulations. ¡ Cooling regulation ¡ Integrated solar regulation ¡ Anti-legionella system ¡ Modular design ¡ Regulation of...

Open the catalog to page 10
Inverter Heat Pumps 2010-11 - 11

11 Device type CMF 120 CMF 160 CMT 120 CMT 160 Design Heating only Heating/cooling Heating/cooling Heating/cooling Inverter technology System Air/water Air/water Air/water Air/water Storage tank for hydraulic decoupling of volumetric flows optional optional Series 150 l Series 150 l Electric booster heating 3 kW optional optional Series 9,0 kW Series 9,0 kW Water heating optional optional Series Series Emergency heating control optional optional Series Series Heating output min / max kW 3,5 - 11,0 5,0 - 16,0 3,5 - 11,0 5,0 - 16,0 Rated heating output for A10/W35 1) kW 10,5 15,3 10,5 15,3...