Catalog excerpts
COMFORT AIR-CONDITIONERS Issue 2012 Comfort air-conditioners Wall units Inverter air-conditioning systems Ceiling cassettes Floor and under ceiling chests Multisplit air-conditioning systems Quality with systems
Open the catalog to page 1REMKO – THE CUSTOMER ORIENTATED SYSTEM PROVIDER FOR THE WHOLE YEAR Quality with systems AIR-CONDITIONING Air-conditioners Mobile air-conditioners Comfort air-conditioners Hot air heating systems Mobile hot air heating systems Stationary hot air heating systems Heat pumps Inverter heat pumps Heat pump packages Heat pump solar packages Chilled water systems Chillers Dehumidifiers Mobile dehumidifiers Pool dehumidifiers
Open the catalog to page 2Comfort air-conditioners Page Series 4-5 An environment for your well being 6-7 MIMSTYLE Inverter wall units ATY 8-9 Inverter high wall units RVT 10-11 Ceiling cassette inverter units RVD 12-13 Floor and under-ceiling chests RXT 14-17 Inverter multisplit systems MVT
Open the catalog to page 3COMFORT AIR-CONDITIONERS Reduce energy consumption through better efficiency For better well being The ideal product range ■ Warm and humid air reduces the human efficiency and concentration. Already up from 22°C room temperature your efficiency reduces by 5 % and even more with every rising centigrade. How often this temperature limit will be exceeded within the summer time everybody knows. Do not allow high summer temperatures to reduce your efficiency and general well being. ■ Room air is often polluted with dust and bacteria. Air-conditioners from REMKO have an integrated air-filter,...
Open the catalog to page 4Create a stable environment for your well being
Open the catalog to page 5INVERTER WALL UNITS ATY series Cooling and heating Air-conditioners to feel good in living areas with high requirements REMKO ATY REMKO combines exclusive design with optimum comfort The exclusive design and high level of comfort differentiate our range from traditional air conditioning units and blend them harmonious into every room of your home. Thanks to modern inverter technology air conditioners work very efficient. Highest comfort based on reduced air outlet temperature differences. As important as the design is a fact which is noticeable from the very first moment: the air quality....
Open the catalog to page 6Technical data Model Cooling capacity Heating capacity Energy efficiency class - cooling Energy efficiency class - heating Yearly cooling/heating energy consumption 500 h Operational area (size of room) approx. Operating range - indoor unit Operating range - outdoor unit - cooling Operating range - outdoor unit - heating Nominal air volume per stage Sound pressure level per speed - indoor unit 1) Sound pressure level - outdoor unit 1) Power supply Cooling / heating power consumption Refrigerant connection, injection pipe Refrigerant connection, suction pipe Refrigerant connection, suction...
Open the catalog to page 7INVERTER HIGH WALL UNITS RVT series Cooling and heating REMKO RVT Reduced energy consumption through better efficiency REMKO RVT Series inverter air conditioning units work extremely efficient. As the room temperature rises, the inverter switches on slowly, and only cools until the desired temperature is once again reached. This results in only minimum temperature fluctuations and thus longer full load operation. This not only saves on energy costs, but also prevents unnecessary start-up sounds. ■ Simple installation on the wall ■ Specification panel of the compressor ■ Inverter technology...
Open the catalog to page 8Quality seal Room air-conditioners Technical data Model Cooling capacity Heating capacity Energy efficiency class - cooling Energy efficiency class - heating Operational area (size of room) approx. Operating range - indoor unit Operating range - outdoor unit - cooling Operating range - outdoor unit - heating Yearly cooling/heating energy consumption 500 h Nominal air volume per stage Sound pressure level per speed - indoor unit 1) Sound pressure level - outdoor unit 1) Power supply Power consumption Cooling / heating Refrigerant connection Refrigerant connection, suction pipe Refrigerant...
Open the catalog to page 9CEILING CASSETTE INVERTER UNITS RVD series Cooling and heating Cassette size Series RVD 681-1051 DC REMKO RVD Reduce energy consumption through better efficiency Due to its flat design and its whisper-quiet operation, the RVD Series inverter air conditioning system is ideal for use in the office. Thanks to the latest inverter technology from REMKO, this ceiling-mounted cassette unit operates particularly reliable and efficient. ■ Inverter technology saves on energy costs. This translates to maximum comfort, as temperature fluctuations in exiting air are reduced to a minimum. ■ Noiseless...
Open the catalog to page 10Quality seal Room air-conditioners Technical data Model Cooling capacity Heating capacity Energy efficiency class - cooling Energy efficiency class - heating Yearly cooling/heating energy consumption 500 h Operational area (size of room) approx. Operating range - indoor unit Operating range - outdoor unit - cooling Operating range - outdoor unit - heating Nominal air volume per stage Sound pressure level per speed - indoor unit 1) Sound pressure level - outdoor unit 1) Power supply Cooling / heating power consumption Refrigerant connection, suction pipe Refrigerant connection, suction pipe...
Open the catalog to page 11FLOOR AND UNDER CEILING CHESTS RXT series Cooling and heating REMKO RXT Reduce energy consumption through better efficiency Due to its flat design and its whisper-quiet operation, the RVD Series inverter air conditioning system is ideal for use in the office. Thanks to the latest inverter technology from REMKO, this floot and ceiling mounted unit operates particularly reliable and efficient. ■ Simple installation on the wall or beneath the ceiling ■ Fitted as standard with infrared remote controller ■ Temperature-controlled winter programme for cooling operation to -15 °C ■ Delivery...
Open the catalog to page 12Quality seal Room air-conditioners Technical data Model Cooling capacity Heating capacity Energy efficiency class - cooling Energy efficiency class - heating Yearly cooling energy consumption 500 h Operational area (size of room) approx. Operating range - indoor unit Operating range - outdoor unit - cooling Operating range - outdoor unit - heating Nominal air volume per stage Refrigerant Sound pressure level per speed - indoor unit 1) Sound pressure level - outdoor unit 1) Power supply Cooling / heating power consumption Refrigerant connection Refrigerant connection, suction pipe Condensate...
Open the catalog to page 13All REMKO GmbH & Co. KG catalogs and technical brochures
-
Brine-Water Heatpumps
28 Pages
-
Pool dehumidifiers
8 Pages
-
Professional dehumidifiers
4 Pages
-
Mobile dehumidifiers
8 Pages
-
Stationary Heating system
36 Pages
-
Monobloc heatpump
28 Pages
-
ArtStyle Heatpumps
40 Pages
-
Air-Air heatpumps
8 Pages
-
Comfort Air-Conditioners
32 Pages
-
MOBILE HOT AIR HEATING SYSTEMS
28 Pages
-
Local Air Conditioners
12 Pages
-
INDUSTRIAL VACUUM CLEANERS
4 Pages
-
HIGH-PERFORMANCE FANS
8 Pages
Archived catalogs
-
AIR-CONDITIONERS 2012-13
16 Pages
-
Pool dehumidifiers 2010-2011
8 Pages
-
Dehumidifier 2010-11
8 Pages
-
Inverter Heat Pumps 2010-11
28 Pages
-
Comfort air-conditioners 2010-11
28 Pages
-
Air conditioner
12 Pages