Chilled Water Air Conditioning Systems 2010-11
40Pages

{{requestButtons}}

Catalog excerpts

Chilled Water Air Conditioning Systems 2010-11 - 1

Quality through Systems CHILLED WATER AIR CONDITIONING SYSTEMS Chilled water systems Wall-mounted units Ceiling cassette units Wall and ceiling units Ceiling mounted ventilation units Edition 2009/2010

Open the catalog to page 1
Chilled Water Air Conditioning Systems 2010-11 - 2

2 From the development of new technologies to the intensive training of our specialist trading partners – REMKO wins through thanks to its strong performance. As a leader in requirements-based air conditioning and heating technology, we offer a high-performance range of products. ¡ Well thought-through designs with dependable quality ¡ Solid, economical and advanced ¡ The appropriate unit for every need ¡ For heating, pre-warming, thawing, drying, dehumidification and air conditioning Product development ¡ REMKO is focused not on existing solutions, but rather takes the more exclusive...

Open the catalog to page 2
Chilled Water Air Conditioning Systems 2010-11 - 3

3 Product overview Page Series 6-18 Chilled water systems 6 Chilled water systems in stainless steel Cooling capacity 5.2 to 16.0 kW RVS 8 Chilled water systems with adaptive regulation Cooling capacity 12.9 to 21.8 kW KWL 10 Chilled water systems with adaptive regulation Cooling capacity 27.1 to 37.2 kW KWL 12 Chilled water systems Cooling capacity 43.5 to 77.7 kW KWL 14 Chilled water systems with reservoir and pump Cooling capacity 43.5 to 77.7 kW KWL-SP 16 Chilled water systems Cooling capacity 98.1 to 309.1 kW KWL 18 Chilled water systems with reservoir and pump Cooling capacity 98.1 to...

Open the catalog to page 3
Chilled Water Air Conditioning Systems 2010-11 - 4

4 CHILLED WATER AIR CONDITIONING SYSTEMS Use the pipe network all year round - to heat in winter, to cool in summer Environmentally friendly and flexible, the new dimension in application flexibility ¡ Chilled water air conditioning systems can be used for cooling in summer and in winter for heating in combination with a heating boiler. ¡ The insulated connection pipes can be used for both systems. Moreover, in existing buildings, it may be possible to use parts of an intact and sufficiently dimensioned, insulated heating network. ¡ REMKO chilled water air conditioning systems are ideal for...

Open the catalog to page 4
Chilled Water Air Conditioning Systems 2010-11 - 5

5 Simple installation ¡ The Chilled water system is positioned in an exterior location. Its long lifespan is guaranteed by the robust construction of the unit. ¡ Installation can be quickly and easily done by a suitable specialist company. No further specific installation skills are needed. ¡ Connection to the interior units is simple and very fast. The units are flexible and can be mounted on the floor, on the wall, or also beneath the ceiling. Comfortable regulation ¡ Just as in the automatic air conditioning system in a car, the regulator ensures a constant room temperature. Each...

Open the catalog to page 5
Chilled Water Air Conditioning Systems 2010-11 - 6

Dimensions 625 595 1300 460 220 1150 RVS 50 RVS 1000 / 1600 309 805 256 925 433 241 368 670 Chilled water systems RVS 1000 INOX 6 RVS 50 - 1600 INOX RVS 50-1600 units, with an output range between 5.2 to 16.0 kW, are particularly quiet, air-cooled Chilled water systems for external use with winter regulation fitted as standard. The monocoque stainless steel (INOX) or powder-coated steel housing features removable panels. All components are thus easy to reach for maintenance. Thanks to its adaptive regulation function, the RVS 50 Chilled water system does not necessarily require a reservoir....

Open the catalog to page 6
Chilled Water Air Conditioning Systems 2010-11 - 7

Technical data Chilled water systems RVS 50 INOX RVS 1000 INOX RVS 1600 INOX Configuration with no reservoir, adaptive regulation function with reservoir with reservoir Cooling capacity 1) kW 5.2 10.0 16.0 Chilled water outlet temperature °C +5 to +20 +5 to +15 +5 to +15 Operating limits - exterior temperature °C +15 to +45 -10 to +45 -10 to +45 Operating limits (expansion) °C -10 to +45 4) – – Cooling cycles/number of compressors 1/1 1/1 1/1 Refrigerant R 410A R 407C R 407C Air volume max. m³/h 2,200 3,000 6,200 Sound pressure level 2) dB(A) 40.2 43.0 44.0 Power supply V / Hz 230/1~/50...

Open the catalog to page 7
Chilled Water Air Conditioning Systems 2010-11 - 8

8 The standard equipment ¡ A Refrigerant circuit with safety components, scroll compressor and stainlesssteel plate heat exchanger ¡ Installation ready hydraulic circuit with circulation pump, expansion vessel and safety module ¡ Externally easy to operate micro-processor controlled adaptive regulator ¡ Main switch and electrical phase sequencing ¡ Compact design and maintenance-friendly construction ¡ Powder-coated and/or stainless steel housing and condenser protection grille ¡ Wide range of accessories available KWL 130 - 220 KWL 130-220 units, with an output range between 12.9 to 21.8...

Open the catalog to page 8
Chilled Water Air Conditioning Systems 2010-11 - 9

9 Technical data Chilled water systems KWL 130 KWL 160 KWL 180 KWL 220 Chilled water systems with heat pump function KWL 130 H KWL 160 H KWL 180 H KWL 220 H Chilled water systems, stainless steel – – KWL 180 INOX KWL 220 INOX Chilled water systems with heat pump function, stainless steel – – KWL 180 H INOX KWL 220 H INOX configuration with no reservoir, adaptive regulation function Cooling capacity 1) kW 12.9 15.9 18.1 21.8 Thermal output 2) only for KWL...H kW 14.9 17.5 19.8 24.2 Medium outlet temperature, C/H °C +4 to +18 / +25 to +45 Operating limits - exterior temperature, C/H °C +15...

Open the catalog to page 9
Chilled Water Air Conditioning Systems 2010-11 - 10

10 KWL 270-320 (H) KWL 370 (H) 1670 1535 1300 1300 620 1160 The standard equipment ¡ A Refrigerant circuit with safety components, scroll compressor and stainlesssteel plate heat exchanger ¡ Installation ready hydraulic circuit with circulation pump, expansion vessel and safety module ¡ Externally easy to operate micro-processor controlled adaptive regulator ¡ Main switch and electrical phase sequencing ¡ Compact design and maintenance-friendly construction ¡ Powder-coated and/or stainless steel housing and condenser protection grille ¡ Wide range of accessories available KWL 270 - 370 KWL...

Open the catalog to page 10
Chilled Water Air Conditioning Systems 2010-11 - 11

11 Technical data Chilled water systems KWL 270 KWL 320 KWL 370 Chilled water systems with heat pump function KWL 270 H KWL 320 H KWL 370 H Chilled water systems, stainless steel KWL 270 INOX KWL 320 INOX KWL 370 INOX Chilled water systems with heat pump function, stainless steel KWL 270 H INOX KWL 320 H INOX KWL 370 H INOX configuration with no reservoir, adaptive regulation function Cooling capacity 1) kW 27.1 31.5 37.2 Thermal output 2) only for KWL...H kW 29.9 35.1 39.7 Cooling medium outlet temperature °C +4 to +18 / +25 to +45 Operating limits - exterior temperature °C +15 to +45 /...

Open the catalog to page 11