Product catalog summary
Light Sources Overview
This section details specifications for various lamp types, including metal halide, compact fluorescent, quartz, and halogen lamps. Key specifications include wattage, beam width, lampholder type, color temperature, and lumen output. It is noted that these specifications are not binding and should be verified with manufacturers.
Installation Notes
  • Trimless Luminaires: Provides instructions for installing trimless luminaires in plasterboard ceilings, including cutting holes and fitting supports.
  • Luminaires with Bezel: Details the installation process using the ClikFix retainer device.
General Information for Downlights
Outlines minimum ceiling recess dimensions and installation instructions for concrete ceilings. It also discusses insulation classes and safety precautions for different luminaire classes.
Light and Color Fading
Offers recommendations to minimize color fading of light-sensitive objects using UV filters and lamps with limited UV emission. Includes correction factors for calculating maximum exposure time based on light intensity and object sensitivity.
IP Classifications
Explains the Ingress Protection (IP) system, which classifies the degree of protection against dust and moisture for different luminaires.
Ingress Protection (IP) Ratings
Describes IP ratings, which indicate the level of protection a luminaire offers against solid foreign bodies and moisture, ranging from 0 (no protection) to 6 (dust-tight) for solids, and 0 to 8 for water ingress. Impact protection ratings range from 0 to 10.
Control Gears for Downlights
Discusses High Power Factor (HPF) and High Frequency (HF) control gears, which manage power supply to lamps, ensuring long life and stable operation. HF control gears offer advantages such as no strobe effect, improved color stability, and energy savings.
Ballast-Lamp Classification
Classifies ballast-lamp circuits for energy efficiency, highlighting the benefits of HF control gears, such as no flicker, noise-free operation, and longer lamp life.
Dimmable HF Control Gears
1-10V DC dimmable HF control gears allow for manual and automatic lighting control, optimizing energy use and providing flexibility in environments like offices and theatres.
Digital Dimmable HF Control Gears
These systems offer high visual comfort and energy efficiency, integrating with building automation for comprehensive control over lighting and other systems.
Introduction to DALI System
DALI (Digital Addressable Lighting Interface) is a standardized interface for digital communication between control modules and HF control gears, allowing for optimized energy savings and flexible lighting scenarios.
Advantages of DALI HF Control Gears
  • Return of operating status signals for integration into complex building systems.
  • Simultaneous regulation of all HF control gears to desired levels.
  • Unlimited on/off status changes via digital signals.
  • Logarithmic regulation of luminous flux from 1-100% for smooth transitions.
  • Programmable regulation times and a maximum distance of 300m between control module and luminaire.
General Information for Downlights
Includes a table of consumption values and harmonic components for various control gears, emphasizing adherence to CEI EN 60598-1:2001 standards for luminaires.
Electric Lighting Installations
  • Luminaires should be evenly distributed across power supply phases.
  • Specific limits are provided for connecting luminaires under thermal circuit breakers.
  • Harmonic current emissions must comply with the 61000-3-2:/A14:2001 standard.
Emergency Luminaires
Categorizes emergency luminaires as permanent or non-permanent, requiring compliance with EN 60598-2-22 standards and periodic testing and replacement of Ni/Cd batteries.
Transformers for Low Voltage Lamps
Low-voltage lamps require transformers to supply appropriate voltage, with HF transformers offering constant output voltage and better dimming features.
Framing Projectors
Framing projectors use lenses and plates to create various light frames, with specifications for different configurations and lux levels provided.
Certifications
All luminaires conform to Italian standard CEI EN 60598-1.
See more

Catalog excerpts

Cat_2012_appendix_INT'L_Ver.pdf-3

LIGHT SOURCES Beam width MTICDM-TM] METAL HALIDE MT (CDM-TC] CDM-T MASTER COLOUR METAL HALIDE SINGLE ENDED ELITE CDM-T MASTER COLOUR HQIT [Osram] HQIT (Osram] HQIT [Osram] MASTER COLOUR, CERAMIC TECHNOLOGY MASTER COLOUR, CERAMIC TECHNOLOGY MASTER COLOUR, CERAMIC TECHNOLOGY METAL HALIDE DOUBLE ENDED METAL HALIDE DOUBLE ENDED CERAMIC TECHNOLOGY METAL HALIDE DOUBLE ENDED CERAMIC TECHNOLOGY MC ME [HIE] METAL HALIDE ELLIPTICAL METALARC TRASPARENTE METAL HALIDESINGLE ENDED METAL HALIDESINGLE ENDED WITH INTEGRAL REFLECTOR CDMR MINI METAL HALIDE WITH INTEGRAL REFLECTOR METAL HALIDE (ALUMINIUM REFLECTOR]...

 Open the catalog to page 3
Cat_2012_appendix_INT'L_Ver.pdf-4

LIGHT SOURCES Beam width COMPACT FLUORESCENT FSQ (TC-DE] COMPACT FLUORESCENT |4 PIN] FSM H (TC-TE] COMPACT FLUORESCENT |4 PIN] _AMP DATA SHOWN IN THIS CATALOGUE ARE NOT BINDING, PLEASE REFER TO LAMP MANUFACTURER DATA FOR EXACT CONFIRMATION. BEFORE PROCEEDING TC ANY INSTALLATION, ALWAYS CHECK SUITABILITY OF THE LAMP FOR THE DESIRED APPLICATION, REGGIANI SPA ILLUMINAZIONE RESERVES THE RIGHTS TO TAKE INTC CONSIDERATION THE ORDER FOR LAMPS IN RELATION TO THE CUSTOMER'S REQUIRED QUANTITY AND TO THE MINIMUM PURCHASE LOT OF GOODS FIXED BY THE LAMP

 Open the catalog to page 4
Cat_2012_appendix_INT'L_Ver.pdf-5

LIGHT SOURCES Beam width_Lamphoider HRG (QR-CB 35] QUARTZ LAMP COOL-BEAM HRG IQR-CB51J QUARTZ LAMP COOL-BEAM MAINS VOLTAGE HALOGEN LAMPS _AMP DATA SHOWN IN THIS CATALOGUE ARE NOT BINDING, PLEASE REFER TO LAMP MANUFACTURER DATA FOR EXACT CONFIRMATION, BEFORE PROCEEDING TC ANY INSTALLATION, ALWAYS CHECK SUITABILITY OF THE LAMP FOR THE DESIRED APPLICATION, REGGIANI SPA ILLUMINAZIONE RESERVES THE RIGHTS TO TAKE INTC CONSIDERATION THE ORDER FOR LAMPS IN RELATION TO THE CUSTOMER'S REQUIRED QUANTITY AND TO THE MINIMUM PURCHASE LOT OF GOODS FIXED BY THE LAMP

 Open the catalog to page 5
Cat_2012_appendix_INT'L_Ver.pdf-6

LIGHT SOURCES Beam width_Lamphoider HDG (QT-DE] QUARTZ TUBULAR 74,9 mm _120_R7s_2950_2300 _AMP DATA SHOWN IN THIS CATALOGUE ARE NOT BINDING, PLEASE REFER TO LAMP MANUFACTURER DATA FOR EXACT CONFIRMATION, BEFORE PROCEEDING TC ANY INSTALLATION, ALWAYS CHECK SUITABILITY OF THE LAMP FOR THE DESIRED APPLICATION, REGGIANI SPA ILLUMINAZIONE RESERVES THE RIGHTS TO TAKE INTC CONSIDERATION THE ORDER FOR LAMPS IN RELATION TO THE CUSTOMER'S REQUIRED QUANTITY AND TO THE MINIMUM PURCHASE LOT OF GOODS FIXED BY THE LAMP

 Open the catalog to page 6
Cat_2012_appendix_INT'L_Ver.pdf-7

INSTALLATION NOTES INSTALLATION OF "TRIMLESS" LUMINAIRES The spotlight support is fitted into the plasterboard false celling (thickness 9-12.5-15mm] and plaster is smoothed around the hole The side tabs need to be eliminated for the support to be fitted into the 1 5mm thick false ce i Line 3ut out hoLe, size required Fit support Fix support with seLf tapping screws -it Luminaire body into ceiLmg cut-out AppLy IOS refLector

 Open the catalog to page 7
Cat_2012_appendix_INT'L_Ver.pdf-8

INSTALLATION NOTES INSTALLATION OF LUMINAIRES "WITH BEZEL" The bezel is placed over the hole m the false celling, then fixed using the innovative ClikFix retainer device Out out hole, size requirec View from ceiling voie -it luminaire body into ceiling cut-out Dlace bezel over hole Dush down on ClikFix retainer device Remove luminaire nstall bezel To remove the bezel, twist the ClikFix retainer device upwards using a screwdriver or other suitable tool inserted between spring clip and support pin

 Open the catalog to page 8
Cat_2012_appendix_INT'L_Ver.pdf-9

GENERAL INFORMATION FOR DOWNLIGHTS CONTAINER FOR CONCRETE CEILINGS INSTALLATION INSTRUCTIONS 1 Prepare the container for installation by fastening the cover on the formwork with 2 Drill the bottom of the container with holes and prepare the empty conduits for the power supply making sure no concrete is drawn in. 3 Engage the indentations at the bottom of the container in the holes on the cover. U Remove the formwork to gain access to the ceiling recess. In the case of concrete ceilings with lined surface, fit the ceiling recess in the concrete by means of an expanded polystyrene cylinder (remove...

 Open the catalog to page 9
Cat_2012_appendix_INT'L_Ver.pdf-10

GENERAL INFORMATION FOR DOWNLIGHTS LIGHT AS CAUSE OF COLOUR FADING The degree of protection the luminaire provides against the ingress of dust and moisture s classified according to the Ingress Protection [IP] System. The protection degree for each type of luminaire we manufacture tells you the type of orotection that we guarantee when a luminaire comes in contact with either solid foreigr oodles or from the ingress of moisture. n order to minimize fading of light-sensitive objects, the use of UV filters is recommendec and/or lamps with limited UV emission. Efficiency ofthe UV filters depends...

 Open the catalog to page 10
Cat_2012_appendix_INT'L_Ver.pdf-11

GENERAL INFORMATION FOR DOWNLIGHTS AU kinds of lamps, whether discharge or fluorescent require a device to control the oower supply current. This task can be performed by electromagnetic control gear whose characteristics correspond to those of the lamp in question. In other words, a non-specific control gear cannot power a lamp. The most economical way of powering a lamp is to use an electromagnetic control gear which is known to have long life (over 25 years] providing the indications given in the assembly instructions provided with all luminaires are respected (for example: never cover a recessed...

 Open the catalog to page 11
Cat_2012_appendix_INT'L_Ver.pdf-12

GENERAL INFORMATION FOR DOWNLIGHTS HF CONTROL GEARS FOR FLUORESCENT LAMPS, Current fluorescent lamps - sensitive to sudden changes in voltage, which drastically "educe their chromatic yield and life - may benefit from the use of HF control gears, as they maintain the luminous flux within narrower tolerance limits and considerably "educe energy losses n brief, the mam advantages of HF control gears are — no strobe effect duringnormaloperation,duetothehighworkmgfreguency^ = — noise-free operation, an important characteristic for environments that reguire absolute silence, or at least the absence...

 Open the catalog to page 12
Cat_2012_appendix_INT'L_Ver.pdf-13

GENERAL INFORMATION FOR DOWNLIGHTS 1-10V DC DIMMABLE HF CONTROL GEARS, The evolution of lighting systems is towards a more rational use of light sources. In this sense, an important role is played by dirnrning/regulating systems, of which the 1-10V DC analogue version represents the simplest and most economical solution The typical applications of these systems are offices, conference rooms, cinemas, anc theatres, that is, all environments in which a fine adjustment of the lighting is necessary .urninaires normally work in combination with other devices (presence detectors, light sensors, etc.],...

 Open the catalog to page 13

All Reggiani Illuminazione catalogs and technical brochures

  1. Outline System

    116  Pages

  2. MOOD PRO

    108  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.