RAIS VIVA-L 100 - 1

USER MANUAL MANUEL DE L’UTILISATEUR VIVA L USA jJjJj Tested& Portland CJJJJJ^S OMNI-Test Laboratories, Inc. Report Number: 0138WS017S

Open the catalog to page 1
RAIS VIVA-L 100 - 2

VIVA 100/120/160 L USA Sparepart drawing Illustration des pièces détachées 6

Open the catalog to page 2
RAIS VIVA-L 100 - 3

VIVA 100/120/160 L G USA Sparepart drawing Illustration des pièces détachées 6

Open the catalog to page 3
RAIS VIVA-L 100 - 4

User Manual VIVA L USA - US English FIRE ENVIRONMENTALLY FRIENDLY! 5 Eco-friendly advices for sensible heating - common sense both environmentally and economically. 1. Effective lighting. Use small pieces of wood (fir tree) and a suitable fire lighter, for example paraffined wood wool/sawdust. Open the air damper, so plenty of air is fed to the stove and the gases from the heated wood can burn rapidly. 2. Light the fire with only little wood at a time - this gives the best combustion. Remember plenty of air for every time new wood is added. 3. When the flames are diminished, adjust the air...

Open the catalog to page 4
RAIS VIVA-L 100 - 5

User Manual LIST OF CONTENT - VIVA L USA OMNI report no. : # 0138WS017E Revision Date (DMY) SPARE PART DRAWINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 CONVECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

Open the catalog to page 5
RAIS VIVA-L 100 - 6

User Manual VIVA L USA - US English Introduction Congratulations on the purchase of your new RAIS woodburning stove. A RAIS woodburning stove is more than just a source of heat, it is a symbol of the emphasis you put on decorating your home with superiorly designed high-quality products. PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW RAIS STOVE. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.SAVE THIS MANUAL AND KEEP IT HANDY FOR EASY REFERRAL. “DO NOT INSTALL IN A MOBILE HOME” “WARNING: Do not overfire. If the stovetop or...

Open the catalog to page 6
RAIS VIVA-L 100 - 7

User Manual U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2020 particulate emission standards using crib wood. 1.1 g/hr, Method 28R This wood heater needs periodic inspection and repair for proper operation. It is against federal regulations to operate this wood heater in a manner inconsistent with operating instructions in this manual. This wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this...

Open the catalog to page 7
RAIS VIVA-L 100 - 8

User Manual VIVA L USA - US English

Open the catalog to page 8
RAIS VIVA-L 100 - 9

User Manual Convection All RAIS stoves are convection stoves, which means that the sides of the stove never get too hot. Convection works by pulling cold air into the system at the base of the stove and up through the convection duct that is located along the combustion chamber of the stove. The heated air is released from the top of the stove, creating rapid air circulation in the room. Glass and replacement of glass. All RAIS stoves supplied with Robax® glass in the door. Robax® glass is a ceramic glass type suitable for stoves. The glass is installed from RAIS as an integral part of the...

Open the catalog to page 9
RAIS VIVA-L 100 - 10

User Manual Chimney RAIS stoves must be installed using a Class A UL 103 HT approved factory-built chimney system or a code-approved masonry chimney with a flue liner. In Canada, the appliance must be connected to a factory-built chimney conforming to CAN/ULCS629. The chimney pipe must be 6” in diameter. The chimney must extend through the roof at least 3’ (1m), and 2’ (.6m) above any structure within 10’ (3m). The condition and height of the chimney are very important for optimal use of the stove and we recommend a total minimum height of 10’ (3m). Note the chimney connector pipe should...

Open the catalog to page 10
RAIS VIVA-L 100 - 11

User Manual VIVA L USA - US English User Manual VIVA L USA - US English Connector Pipe 18” (46cm) below ceiling E. Ceiling Support Box or Joist Shield/Firestop Spacer For venting vertically into a Class A chimney, a single wall pipe (at least 24 gauge) may be used in the room where the stove is installed. Refer to the manufacturer’s instructions for the connection to the listed chimney. The chimney/stove pipe must not be smaller than 6” (15cm) in diameter. For venting directly into a masonry chimney or through a thimble, the top of the single wall pipe must be at least 18” (46cm) below a...

Open the catalog to page 11
RAIS VIVA-L 100 - 12

User Manual If thIs stove Is not Installed properly, a home fIre may result. to reduce thIs rIsk, please follow the dIrectIons for InstallatIon carefully. Installation Precautions and Specifications Before installation, remember to consult your local building inspector or fire marshal to determine the need to obtain a permit. Also enquire about restrictions and installation inspection requirements in your area. If utilizing an existing chimney, it is recommended that a professional mason or stove installer do a complete check-up of the chimney, liner, and flue beforehand. In order for the...

Open the catalog to page 12
RAIS VIVA-L 100 - 13

jjyrv]§r rais a/s Industrivej 20, DK-9900 Frederikshavn, Denmark Model: VIVA L USA. VIVA L G USA. VIVA L CA USA. VIVA L G CA USA Solid Fuel Room Heater For Use With Solid Wood Fuel Only OMNI-Test Laboratories, inc. Report No. # 0138WS017S Model Modele Made in Denmark Fabrique au Danemark Clearances to combustible surfaces **Rear/Top vent option Parallel wall Installation Corner Installation Ceiling FLOOR PROTECTOR Single Wall Vent Pipe / Tuyau d'evacuation d'un Minimum Clearance / Ecartement minimim . seul mur A. Side Wall to Unit / Mur lateral a L'unite 21" / 533mm...

Open the catalog to page 13
RAIS VIVA-L 100 - 14

Évitez de surshauffer-si le feu ou la cheminée rougeoie, vois surchauffez. Do not overfire - if heater or chimney connector glows, you are overfiring. DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE ATTENTION: CHAUD PENDANT LE FONCTIONNEMENT - NE PAS TOUCHER ECARTE LES ENFANTS ET LES VETEMENTS- LE CONTACT PEU CAUSER DES BRULURES. CONSULTE LA PLAQUE ET LES INSTRUCTIONS. TENIR LES MEUBLES ET AUTRES MATIERES COMBUSTIBLES A GRANDE DISTANCE DE LAPPAREIL. Contactez les Autorités des Bâtiments et des pompiers concemant les restrictions et inspections d'installation dans votre région....

Open the catalog to page 14