RAIS SIRA & RAIS SIRA SOAPSTONE
17Pages

{{requestButtons}}

Catalog excerpts

RAIS SIRA &  RAIS SIRA SOAPSTONE - 1

1 ENGLISH RAIS - manual for SIRA & SIRA SOAPSTONE USER MANUAL RAIS SIRA & RAIS SIRA SOAPSTONE

Open the catalog to page 1
RAIS SIRA &  RAIS SIRA SOAPSTONE - 3

4 ENGLISH RAIS - manual for SIRA & SIRA SOAPSTONE 5 ENGLISH RAIS - manual for SIRA & SIRA SOAPSTONE RAIS SIRA RAIS SIRA SOAPSTONE Nominal outputt (kW): 5 5 Min./Max. output (kW): 2-6 2-6 Heating area l(m2): ca. 80 ca. 80 Stove’s width/depth/height (mm): 504-408-960 551-438-1000 Combustion chamber’s width/depth/height(mm): 372-238-300 372-238--300 Recommended amount of wood when fuelling (kg): (Distributed on 2-3 logs of wood of approx. 25 cm) 1,7 1,7 Min. uptake / Min. draught (Pascal): -11 -11 Weight (kg): 145 225 Smoke gas mass flow (g/s): 5,99 5,99 Smoke gas temperature (°C): 259 259...

Open the catalog to page 3
RAIS SIRA &  RAIS SIRA SOAPSTONE - 4

6 ENGLISH RAIS - manual for SIRA & SIRA SOAPSTONE 7 ENGLISH RAIS - manual for SIRA & SIRA SOAPSTONE Convection RAIS stoves are convection stoves. This means that the stove’s back and side panels are not over-heated. Convection means that there is a circulation of air, which ensures that the heat is distributed more evenly throughout the entire room. The cold air is drawn in at the base of the stove up through the convection channel, which runs along the stove’s combustion chamber. The heated air pours out at the top of the stove, which ensures a circulation of warm air throughout the room....

Open the catalog to page 4
RAIS SIRA &  RAIS SIRA SOAPSTONE - 5

8 ENGLISH RAIS - manual for SIRA & SIRA SOAPSTONE 9 ENGLISH RAIS - manual for SIRA & SIRA SOAPSTONE Chimney The chimney is the driving force which makes the stove function. In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure the correct draught of 14 to 18 Pa so as to clear the products of combustion and prevent problems of smoke emanating into the room when firing. NOTE: A chimney height of not less than 4.5 metres measured vertically from the outlet of the stove to the top of the chimney should be satisfactory. Alternatively the calculation...

Open the catalog to page 5
RAIS SIRA &  RAIS SIRA SOAPSTONE - 6

10 ENGLISH RAIS - manual for SIRA & SIRA SOAPSTONE 11 ENGLISH RAIS - manual for SIRA & SIRA SOAPSTONE Sira Manufacturer’s Plate...

Open the catalog to page 6
RAIS SIRA &  RAIS SIRA SOAPSTONE - 7

12 ENGLISH RAIS - manual for SIRA & SIRA SOAPSTONE 13 ENGLISH RAIS - manual for SIRA & SIRA SOAPSTONE The flue outlet spigot, which you will find in a pouch in the stove, and the holder for the upper flue diverter are assembled with 3 M6x20 head cap screws and M6 nuts. The smoke leader and baffelplate are assembled in reverse order. Assemble the reflector plate and backpanel. Installation of soapstone List of materials (individual components for assembling soapstone) Item number Product designation Number 3067001/3067002 Top plate without hole/ Top plate with hole 2 3067006 Sidestone 1...

Open the catalog to page 7
RAIS SIRA &  RAIS SIRA SOAPSTONE - 8

14 ENGLISH RAIS - manual for SIRA & SIRA SOAPSTONE 15 ENGLISH RAIS - manual for SIRA & SIRA SOAPSTONE Installation distance in case of combustible wall To find out whether the wall next to where the stove is going to be installed is flammable, you should contact your building contractor or the local building authorities. The hearth should be able to accommodate the weight of the stove. The chimney must be independently supported by wall brackets or a ceiling support plate. The weight of the stove is indicated in the brochure. The stove should always be installed on a non-combustible hearth...

Open the catalog to page 8
RAIS SIRA &  RAIS SIRA SOAPSTONE - 9

16 ENGLISH RAIS - manual for SIRA & SIRA SOAPSTONE 17 ENGLISH RAIS - manual for SIRA & SIRA SOAPSTONE For the Installer Finally before firing the stove for the first time a check should be made to ensure that the assembly and stove installation has been satisfactory and that there are no leaks in any seals in the appliance and appliance connections to the chimney. Ensure that the appliance and chimney flue are functioning correctly before finally handing over to the user. If necessary read the later parts of this manual for guidance on care required when first lighting. Inform the user that...

Open the catalog to page 9
RAIS SIRA &  RAIS SIRA SOAPSTONE - 10

18 ENGLISH RAIS - manual for SIRA & SIRA SOAPSTONE 19 ENGLISH RAIS - manual for SIRA & SIRA SOAPSTONE Operating instructions Please note that HETAS Approval only covers the use of wood in the stove and approval does not cover the use of other fuels either alone or mixed with other fuels, nor does it cover instructions for the use of other fuels. Fuel The stove is designed and approved in accordance with EN 13240 and NS 3058 for stoking split, dried firewood. The firewood must have a water content of 15-22% and its maximum length should be the length of the combustion chamber minus 50-60 mm....

Open the catalog to page 10
RAIS SIRA &  RAIS SIRA SOAPSTONE - 11

20 ENGLISH RAIS - manual for SIRA & SIRA SOAPSTONE 21 ENGLISH RAIS - manual for SIRA & SIRA SOAPSTONE Regulating the combustion air All RAIS stoves are equipped with a one-handed operating lever for regulating the damper. The stove-specific regulating mechanisms can be seen on the diagrams. Primary air is the combustion air added to the primary combustion zone, i.e. the bed of glowing embers. This air, which is cold, is only used in the lighting stage. Secondary air is the air which is added in the gas combustion zone, i.e. air which contributes to the combustion of the pyrolysis gases...

Open the catalog to page 11
RAIS SIRA &  RAIS SIRA SOAPSTONE - 12

22 ENGLISH RAIS - manual for SIRA & SIRA SOAPSTONE 23 ENGLISH RAIS - manual for SIRA & SIRA SOAPSTONE First usage A careful start pays off. Start with a small fire, so that the wood burning stove can get accustomed to the high temperature. This gives the best start and any damage is avoided. Be aware that a strange but harmless odour and smoke concoction may emanate from the surface of the stove, the first time you fire up. This is because the paint and materials need to harden. The odour disappears quickly, but you should check the ventilation and draught, if possible. See also, the...

Open the catalog to page 12
RAIS SIRA &  RAIS SIRA SOAPSTONE - 13

24 ENGLISH RAIS - manual for SIRA & SIRA SOAPSTONE 25 ENGLISH RAIS - manual for SIRA & SIRA SOAPSTONE Lighting and fuelling TIPS before firing up: Open a door or window close to the wood burning stove. If there is a “storm” in the stove coming from the chimney, it is advisable to place a screwed-up piece of newspaper between the upper baffle plate and the chimney, set the paper on fire, and wait until you hear a “rumbling” noise in the chimney. This means that there definitely is a draught in the chimney and you avoid smoke in the room. To light the stove, use alcohol briquettes or similar,...