RAIS GABO, PINA, VOLA & RAIS VOLA SHOAPSTONE
19Pages

{{requestButtons}}

Catalog excerpts

RAIS  GABO, PINA, VOLA & RAIS VOLA SHOAPSTONE - 1

ENGLISH RAIS - manual for GABO, PINA, VOLA and VOLA SOAPSTONE 1 USER MANUAL RAIS GABO, RAIS PINA, RAIS VOLA & RAIS VOLA SOAPSTONE

Open the catalog to page 1
RAIS  GABO, PINA, VOLA & RAIS VOLA SHOAPSTONE - 3

ENGLISH RAIS - manual for GABO, PINA, VOLA and VOLA SOAPSTONE 4 ENGLISH RAIS - manual for GABO, PINA, VOLA and VOLA SOAPSTONE 5 RAIS GABO RAIS PINA RAIS VOLA RAIS VOLA SOAPSTONE Nominal outputt (kW): 5 5 5 5 Min./Max. output (kW): 2-6 2-6 2-6 2-6 Heating area l(m2): ca. 80 ca. 80 ca. 80 ca. 80 Stove’s width/depth/height (mm): 510-460-1005 552-455-1120 530-421-1190 540-430-1230 Combustion chamber’s width/depth/height(mm): 376-245-367 376-245-367 376-245-367 376-245-367 Recommenden amount of wood when fuelling (kg): (Distributed on 2-3 logs of wood of approx. 25 cm) 1,5 1,5 1,5 1,5 Min....

Open the catalog to page 3
RAIS  GABO, PINA, VOLA & RAIS VOLA SHOAPSTONE - 4

ENGLISH RAIS - manual for GABO, PINA, VOLA and VOLA SOAPSTONE 6 ENGLISH RAIS - manual for GABO, PINA, VOLA and VOLA SOAPSTONE 7 Convection RAIS stoves are convection stoves. This means that the stove’s back and side panels are not over-heated. Convection means that there is a circulation of air, which ensures that the heat is distributed more evenly throughout the entire room. The cold air is sucked in at the base of the stove up through the convection channel, which runs along the stove’s combustion chamber. The heated air pours out at the top of the stove, which ensures a circulation of...

Open the catalog to page 4
RAIS  GABO, PINA, VOLA & RAIS VOLA SHOAPSTONE - 5

ENGLISH RAIS - manual for GABO, PINA, VOLA and VOLA SOAPSTONE 8 ENGLISH RAIS - manual for GABO, PINA, VOLA and VOLA SOAPSTONE 9 Chimney The chimney is the driving force which makes the stove function. In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure the correct draught of 14 to 18 Pa so as to clear the products of combustion and prevent problems of smoke emanating into the room when firing. NOTE: A chimney height of not less than 4.5 metres measured vertically from the outlet of the stove to the top of the chimney should be satisfactory....

Open the catalog to page 5
RAIS  GABO, PINA, VOLA & RAIS VOLA SHOAPSTONE - 6

ENGLISH RAIS - manual for GABO, PINA, VOLA and VOLA SOAPSTONE 10 ENGLISH RAIS - manual for GABO, PINA, VOLA and VOLA SOAPSTONE 11...

Open the catalog to page 6
RAIS  GABO, PINA, VOLA & RAIS VOLA SHOAPSTONE - 7

ENGLISH RAIS - manual for GABO, PINA, VOLA and VOLA SOAPSTONE 12 ENGLISH RAIS - manual for GABO, PINA, VOLA and VOLA SOAPSTONE 13 ƒO Operation of swivel base If the distributor has already installed a swivel base on the stove, you should do the following: Lift up the positioning bolt and rotate the stove at 15° intervals. When you have reached the desired position, release the positioning bolt, and turn the stove slightly until the bolt clicks into place. RAIS PINA RAIS GAB0 Installation of soapstone (RAIS VOLA SOAPSTONE) List of materials (individual components for assembling soapstone)...

Open the catalog to page 7
RAIS  GABO, PINA, VOLA & RAIS VOLA SHOAPSTONE - 8

ENGLISH RAIS - manual for GABO, PINA, VOLA and VOLA SOAPSTONE 14 ENGLISH RAIS - manual for GABO, PINA, VOLA and VOLA SOAPSTONE 15 5. Carefully place the Soapstone (5) on the socket.(6). 6. On each side mount the 2 flat-head screws (7) through the plate (8). 7. Mount the brash bush (9) on the screw (7) between the plate and the Soapstone. 8. Screw the flat-head screw in the Soapstone bush (10). 9. Mount the topplate (4) - lower the topplate in the slot and push it carefully towards the stove front. 10. Fasten the nut (3) again. 11. Mount the backpanel (2). 12. Mount the screw (1) and fasten...

Open the catalog to page 8
RAIS  GABO, PINA, VOLA & RAIS VOLA SHOAPSTONE - 9

ENGLISH RAIS - manual for GABO, PINA, VOLA and VOLA SOAPSTONE 16 ENGLISH RAIS - manual for GABO, PINA, VOLA and VOLA SOAPSTONE 17 Normal set-up (right-angled) secure base A. Distance to furniture 950 mm Distance to flammable materials: B. - in front (floor) 300 mm C. - to the side (floor) 150 mm D. - to the rear (floor) 150 mm E. - to the side of the wall 400 mm Corner set-up 45¢ª A. Distance to funiture 1050 mm Distance to flammable materials: B. - in front (floor) 300 mm C. - to the side (floor) 150 mm D. - to the rear (floor) 110 mm...

Open the catalog to page 9
RAIS  GABO, PINA, VOLA & RAIS VOLA SHOAPSTONE - 10

ENGLISH RAIS - manual for GABO, PINA, VOLA and VOLA SOAPSTONE 18 ENGLISH RAIS - manual for GABO, PINA, VOLA and VOLA SOAPSTONE 19 Operating instructions Please note that HETAS Approval only covers the use of wood in the stove and approval does not cover the use of other fuels either alone or mixed with other fuels, nor does it cover instructions for the use of other fuels. Fuel The stove is designed and approved in accordance with EN 13240 and NS 3058 for stoking split, dried firewood. The firewood must have a water content of 15-22% and its max. length should be the length of the...

Open the catalog to page 10
RAIS  GABO, PINA, VOLA & RAIS VOLA SHOAPSTONE - 11

ENGLISH RAIS - manual for GABO, PINA, VOLA and VOLA SOAPSTONE 20 ENGLISH RAIS - manual for GABO, PINA, VOLA and VOLA SOAPSTONE 21 The following table shows the calorific value of different types of wood, which have been stored for 2 years, and which have a residual moisture of 15-17%. Wood Kg dry wood pr. m3 compared to beech/oak Hornbeam 640 110% Beech and oak 580 100% Ash 570 98% Maple 540 93% Birch 510 88% Mountain pine 480 83% Fir 390 67% Poplar 380 65% 1 kg of wood yields the same heat energy irrespective of wood type. 1 kg beech merely takes up less space than 1 kg of fir. Drying and...

Open the catalog to page 11
RAIS  GABO, PINA, VOLA & RAIS VOLA SHOAPSTONE - 12

ENGLISH RAIS - manual for GABO, PINA, VOLA and VOLA SOAPSTONE 22 ENGLISH RAIS - manual for GABO, PINA, VOLA and VOLA SOAPSTONE 23 Control If the ash is white and the walls in the combustion chamber sott-free after the stove has been used, the air regulation was set correctly and the wood was sufficiently dry. Using the wood burning stove Adjustment of the air damper. The damper has 3 settings. Position 1 The air damper is closed, which means no air supply. Position 2 Pull the lever until first stop. This position gives full secondary air. During normal stoking the lever is set between...

Open the catalog to page 12
RAIS  GABO, PINA, VOLA & RAIS VOLA SHOAPSTONE - 13

ENGLISH RAIS - manual for GABO, PINA, VOLA and VOLA SOAPSTONE 24 ENGLISH RAIS - manual for GABO, PINA, VOLA and VOLA SOAPSTONE 25 Light the fire and shut the door, leaving the door ajar approx. 10-15 mm. Lighting and fuelling TIPS before firing up: Open a door or window close to the wood burning stove. If there is a “storm” in the stove coming from the chimney, it is advisable to place a screwed-up piece of newspaper between the upper baffle plate and the chimney, set the paper on fire, and wait until you hear a “rumbling” noise in the chimney. This means that there definitely is a draught...

Open the catalog to page 13

All RAIS catalogs and technical brochures

  1. RAIS Q-Tee II

    75 Pages

  2. yde_visio

    1 Pages

Archived catalogs

  1. RAIS CUBE

    1 Pages

  2. RAIS GIZEH

    1 Pages

  3. RAIS GEO

    40 Pages

  4. RAIS 2:1

    32 Pages