insulation specifications
16Pages

{{requestButtons}}

Catalog excerpts

insulation specifications - 1

INSULATION SPECIFICATIONS SUBMITTAL SHEET L77 PINK® Fiberglas® Unbonded Loosefill Insulation Submitted To: Submitted By: Date: ®

Open the catalog to page 1
insulation specifications - 2

EcoTouch® Unfaced Insulation with PureFiber® Technology EcoTouch® Unfaced Insulation is designed to improve the thermal performance of wall and roof/ceiling assemblies. EcoTouch® Insulation fits tightly between framing and is held in place by friction. Cathedral Batts are designed to fit tightly between cathedral rafters and when properly installed, still provide the necessary air ventilation space above the Technical Data Metal Frame Construction Wood Frame Construction Roof/Ceiling Construction zcoTouch® Unfaced Insulation complies with the property requirements of ASTM C665 *R-values...

Open the catalog to page 2
insulation specifications - 3

EcoTouch® Kraft-Faced Insulation with PureFiber® Technology EcoTouch® Kraft-faced Insulation is designed to improve the thermal performance of wall and roof/ceiling assemblies. EcoTouch® Kraft-faced Insulation has a strong asphalt-coated paper facing on one side. Stapling flanges are provided for standard wood frame widths. Cathedral Batts are designed to fit tightly between cathedral rafters without stapling the flanges and when properly installed, still provide the necessary air ventilation space above the insulation. Perm Rating Technical Data Metal Frame Construction Wood Frame...

Open the catalog to page 3
insulation specifications - 4

EcoTouch® Foil faced Insulation with PureFiber® Technology □ Foil Faced Perm Rating 0.50 EcoTouch® Foil faced Insulation is designed to improve the thermal performance of wall and roof/ceiling assemblies. EcoTouch® Foil faced Insulation has an aluminum foil kraft facing on one side. Stapling flanges are provided for standard wood framing Technical Data R-Value* Width Metal Frame Construction Floor/Roof/Ceiling Construction -oil faced EcoTouch® Thermal Batt Insulation complies with the property requirements of ASTM C665, Type III, Class E *R-values differ Find out why in the seller's fact...

Open the catalog to page 4
insulation specifications - 5

Technical Data R-Value* Width Surface Burning Characteristics/Building Code Construction Classification Flame Spread Smoke Developed ICC -edera Specification H H-1-521 F has been canceled and is replaced by ASTM C665 *R-values differ Find out why in the seller's fact sheet on R-values, Higher R-value means greater insulating power Desiccant methoc <raft-faced Insulation will burn and must not be left exposed. The facing must be installed in substantial contact with the finish material. Protect facing from open flame or heat source PROPINK FastBatt® Insulation with PureFiber® Technology...

Open the catalog to page 5
insulation specifications - 6

Sonobatts® Insulation with PureFiber® Technology Technical Data R-Value* Width Jnfaced Sonobatts® Insulation complies with the property requirements of ASTM C665, Type I and ASTM EI36. Kraft- faced Sonobatts® Insulation complies with the property requirements of ASTM C665, Type II, Class C *R-values differ Find out why in the seller's fact sheet on R-values. Higher R-value means greater insulating power Perm Rating Surface Burning Characteristics/Building Code Construction Classification Products Flame Spread Smoke Developed ICC <raft facing on Sonobatts® Insulation will burn and must not...

Open the catalog to page 6
insulation specifications - 7

PROPINK®L77 PINK® Fiberglas™ Unbonded Loosefill Insulation PROPINK® L77 PINK® Fiberglas™ Unbonded Loosefill Insulation is designed to be mechanically blown into attics but may also be applied in the exterior walls or enclosed cavities of new or existing construction. The product consists of unbonded fiberglass insulation material packaged in bags. Technical Data—Attics Nominal bag weight: 33 lbs R-value* Bags Per 1,000 ft.2 Maximum Net Coverage Minimum Weight/ft.2 Minimum Thickness (in) Minimum Settled Thickness1 Technical Data—Walls R-value* Minimum Thickness Installed Density Lbs./ft.3...

Open the catalog to page 7
insulation specifications - 8

PROPINK Complete™ Blown-in Wall System Technical Data—Insulation Minimum Max. Coverage/ Minimum Weight Min. thickness Density *R-values differ Find out why in the seller's fact sheet on R-values. Higher R-value means greater insulating power Technical Data—Fabric Surface Burning Characteristics/Building Code Construction Classification Test Method Flame Spread Smoke Developed *ASTM standard E84 is used solely to measure and describe properties of products in response to heat and flame under controlled laboratory conditions, and should not be used to describe or approve the fire hazard of...

Open the catalog to page 8
insulation specifications - 9

ThermaGlas® Fiber Glass Loosefill Insulation with PureFiber ® Technology Technical Data Nominal bag weight: 35 lbs. *The higher the R-value, the greater the insulating power. Ask your seller for the fact sheet on R-values. ThermaGlas® Fiber Glass Loosefill Insulation is an alternative to roll or batt insulation in attics, new construction and retrofit applications. Surface Burning Characteristics/Building Code Construction Classification Flame Spread Smoke Developed ThermaGlas ® fiber glass loosefill insulation conforms to the product requirements of ASTM C764 Type I (pneumatic...

Open the catalog to page 9
insulation specifications - 10

SelectSound® Black Acoustic Blanket Technical Data Product Black Acoustic Blanket SelectSound ® Black acoustical blanket complies with the property requirements of ASTM C553, Type III, 250°F maximum use temperature. The noise reduction coefficients of SelectSound ® Black acoustic blanket were derived from tests conducted in accordance with ASTM C423 on a Type A mounting. Surface Burning Characteristics/Building Code Construction Classification Flame Spread Smoke Developed *The surface burning characteristics of these products have been developed in accordance with UL 723 and CAN/ULC-S102-M....

Open the catalog to page 10
insulation specifications - 11

701 Insulation Unfaced Fiber Glass Technical Data R-Value* Width Type 701 Density 1.5 pcf K-value 0.24 Product only available in 24' x 48' sizes. 701 Insulation products comply with the property requirements of ASTM C553, Type III and ASTM C665, Type I. *R-values differ. Find out why in the seller’s fact sheet on R-values. Higher R-value means greater insulating power. Surface Burning Characteristics/Building Code Construction Classification Products Flame Spread Smoke Developed 701 Unfaced Insulation is designed to improve thermal and acoustical performance in applications where the...

Open the catalog to page 11

All QuietZone catalogs and technical brochures

  1. PROPINK®

    2 Pages

  2. HomeSealR™

    2 Pages

  3. InsulGuard?

    2 Pages

  4. JOINTSEALR®

    2 Pages

  5. FOAMULAR®

    4 Pages

Archived catalogs

  1. truwrap

    4 Pages

  2. PROPINK

    6 Pages