1. Catalogs
  2. Promat
  3. Promat TD Board®

Promat TD Board®

Promat TD Board®
1 / 20 PagesView full catalog

Promat TD Board®

Product catalog summary
Description: Promat TD Board® is a rock wool board designed for fire protection of structural steel. It is manufactured under a BS EN ISO 9001 quality management system, is moisture-resistant, and suitable for internal and semi-exposed applications. Installation is done using spiral screws made from galvanized wire.
Advantages: The board requires no maintenance, is moisture-repellent, offers three finishes, is easy to repair, and provides up to 240 minutes of fire protection depending on the fixing method.
Fixing Options: Installation can be done using dry fix solutions with clips or glued fix solutions with noggings and stud welded pins. The dry fix system offers up to 120 minutes of fire protection, while the glued system can provide up to 240 minutes.
Technical Data: The board is non-combustible, with a surface spread of flame classified as Class 1 and a Building Regulations classification of Class 0. It has a nominal density of 180 kg/m3 and is available in thicknesses ranging from 25mm to 60mm.
Installation Methods: Detailed installation methods include clip fix dry joint systems, stud welded pin systems, and adhesive-fix nogging systems, with specific instructions on spacing and positioning of clips, pins, and screws.
Performance and Properties: Promat TD Board® provides up to 240 minutes of fire resistance for structural steelwork, assessed to BS 476: Part 21: 1987. It has a moisture content of 0% in an air-dried state and a maximum water absorption of 60 grams/m2 after 24-hour immersion testing.
Certifications: The board has Certifire Approval No CF 529, ensuring compliance with fire safety standards.
Installation Procedures: For welded pin applications, each layer should be secured with a separate non-return washer. In adhesive-fix nogging applications, the first layer is attached to the noggings, followed by a 120mm adhesive band on the first layer's outer face. The outer layer is then applied and supported with nails until the adhesive sets.
Board Jointing: Butted corner joints use square edge boards with either dry joints and spiral screws or Promat VICUBOND® WR ADHESIVE and nails. Axial joints are made with square butt edges without nails, using adhesive only for glued systems. Foil-faced products can have joints finished with Class ‘0’ foil tape.
Noggings and Fixings: Noggings are made from Promat TD Board® offcuts and glued to steelwork. Cover boards are fixed with spiral screws or adhesive and nails. Boards can also be impaled on welded pins and secured with washers.
Adhesive Usage: Promat VICUBOND® WR ADHESIVE is used for board-to-board and board-to-nogging joints in adhesive systems. It should not be applied on the external face of joints. The adhesive must set hard before applying cover boards, typically taking about 4 hours at 20°C. The adhesive is non-toxic with a pH of 7-9.
Fire Protection Specifications: Tables provide specifications for board thickness and fire resistance periods based on limiting steel temperatures of 550°C and 620°C, guiding the use of clip fixings, welded pin fixings, and adhesive fix noggings for different beam configurations and loading conditions.
Contact Information: Promat provides extensive global service networks with contact details for offices in various countries, including the UK, Belgium, Asia Pacific, Australia, and more.
See more

Catalog excerpts

Promat TD Board®-1

Uniclass L68111:L35 EPIC F811:C21 CI/SfB (28.9) R (K3) Promat TD Board® Structural Steel Fire Protection ...

 Open the catalog to page 1
Promat TD Board®-2

Structural Steel Fire Protection Promat TD Board* is an inert rock wool board used for the fire protection of structural steel. Promat TD Board* is available unfaced or faced with a reinforced scrim or aluminium foil. It is manufactured in accordance with an independently accredited BS EN ISO 9001 quality management system. Promat TD Board* is resistant to the effects of moisture and is suitable for internal and semi-exposed applications. Promat TD Board* is generally installed using Promat TD Board* fixings. These are spiral screws made from 16 s.w.g. galvanised wire. Promat TD Board* is manufactured...

 Open the catalog to page 2
Promat TD Board®-3

Promat TD Board® Structural Steel Fire Protection PERFORMANCE AND PROPERTIES Fire performance Up to 240 minutes fire resistance for structural steelwork, assessed to BS 476: Part 21: 1987 at 550°C and 620°C failure criteria. The unfaced, foil and tissue faced products achieve reaction to fire Euroclass A1 in accordance with BS EN 13501-1. Moisture Promat TD Board® fibres are randomly oriented, avoiding any tendency to promote capillary action or hygroscopic moisture absorption. Moisture content 0% in air-dried state Moisture absorption 0.004% by volume at 20°C and 90% relative humidity Water...

 Open the catalog to page 3
Promat TD Board®-4

Promat TD Board® Structural Steel Fire Protection Certifire Approval No CF 529 Promat TD BOARD® CLIP FIX DRY JOINT BOARD SYSTEM The Promat TD Board® clip fixing system is designed for ultimate speed of application. Its design features allow it to be used with standard steel deck types. The Promat TD Board® clip Promat TD Board fixing solution can be used to provide 2, 3 and 4-sided beam protection for up to 120 minutes. A lightweight, and easily worked fire (120 minute A/V limitation – 200m-1) ® protection board which offers up to 240 minutes fire protection depending on method of fixing, thickness...

 Open the catalog to page 4
Promat TD Board®-5

Promat TD Board® Structural Steel Fire Protection Combined Clip and Stud Welded Pin Dry Joint Systems With concrete decks it may be necessary to fix stud welded pins to the top flange in place of clips. Fig 4 Certifire Approval No CF 529 Fig 5 MAINTAINING COMPARTMENTATION A A If Promat TD Board® is also required to W>100mm provide fire insulation across the beam or column in order to maintain D C D C compartmentation to the criteria of BS 476: Part 22: 1987 (maintaining insulation to 2-sided box 3-sided box average temperature rise of 140ºC, Dimensions: maximum temperature rise 180ºC), then the...

 Open the catalog to page 5
Promat TD Board®-6

Promat TD Board® Structural Steel Fire Protection Certifire Approval No CF 529 Promat TD Board® STUD WELDED PIN DRY JOINT BOARD SYSTEM A stud welded pin solution with dry joints. This dry fix pin solution can be used for 2, 3 and 4-sided beam protection for a period of up to 120 minutes. INSTALLATION METHOD 1. Clean the local area for pin welding and fix Typical Details stud pin using arc or CD welds, ensuring a Fig 8 good contact has been achieved. Test weld by bending pin. Fig 9 2. Impale the Promat TD Board® boards onto the stud welded pins using the deck soffit as a guide. 3. Push 38mm diameter...

 Open the catalog to page 6
Promat TD Board®-7

Promat TD Board® Structural Steel Fire Protection Certifire Approval No CF 529 B A A A D C B D Fig 11 D D 2-sided box with stud welded pins Dimensions: A Stud welded pins at maximum 600mm centres for 2000mm board (500mm centres for 1200mm boards). B Stud welded pins at maximum 100mm centres, 20mm minimum from edge of board. C Spiral screws at maximum 150mm centres. D Stud welded pins at maximum 900mm centres for bottom flange. Fig 12 Fig 13 20mm minimum W>100mm W<100mm Spiral screws at 150mm Central row of pins required maximum at maximum 900mm centres centres Central row of welded pins required...

 Open the catalog to page 7
Promat TD Board®-8

Promat TD Board® Structural Steel Fire Protection Certifire Approval No CF 529 ADHESIVE-FIX NOGGING DRY JOINT BOARD SYSTEM A nogging solution which removes the necessity for adhesive-fix for board-to-board and board-tonogging joints. INSTALLATION METHOD 1. Cut 120mm wide noggings (C) to suit web depth, using same thickness material as The board-to-board edge joints are fixed with spiral screws at 200mm centres. The adhered noggings are at 1000mm fixing centres. This fixing solution can be used for 2, 3 and 4-sided beam protection for up to 120 minutes. the cover protection. For web depths of...

 Open the catalog to page 8
Promat TD Board®-9

Promat TD Board® Structural Steel Fire Protection Certifire Approval No CF 529 Fig 17 A B A 2-sided box using a combination of noggings and stud welded pins Dimensions: A Welded pins at maximum 900mm centres for 2000mm board (500mm centres for 1200mm boards). B Welded pins at maximum 100mm (minimum 20mm) from board edge. 20mm minimum 100mm maximum 25mm maximum W≤100mm W>100mm Fig 19 Fig 18 100mm maximum Board fixed by Promat VICUCLAD® WR ADHESIVE to shelf angle Central row of pins required at maximum 900mm centres. 2-sided box 2-sided box W limit is 100mm. Where W >100mm a shelf angle or similar...

 Open the catalog to page 9
Promat TD Board®-10

Promat TD Board® Structural Steel Fire Protection Certifire Approval No CF 529 ADHESIVE-FIX NOGGING OR STUD WELDED PIN ADHESIVE BOARD JOINT SYSTEMS The application of Promat VICUBOND® WR ADHESIVE enhances the fire performance over the dry joint systems for the 120, 180 and 240 minutes. The adhesive joint systems are capable of providing up to 240 minutes fire protection. Installation Method (Nogging Fix) FIXING BOARDS TO NOGGINGS 1. Cut 120mm wide noggings to suit web depth, using same thickness material as the cover Wherever three or four-sided protection protection. For web depths of 500mm...

 Open the catalog to page 10
Promat TD Board®-11

Promat TD Board® Structural Steel Fire Protection Fixing Pattern Minimum 120mm wide noggings Fig 22 A B C 30mm 30mm Fixing method using adhesive noggings, nails and adhesive board-to-board joints Dimensions: A Noggings at maximum 1000mm centres. B Nails at maximum 150mm centres. C Nails at maximum 400mm centres (maximum 30mm from edge of board joint). Stud Welded Pin Fixing Arrangement B Fig 23 A A A D B D C C 3-sided box with stud welded pins Dimensions: A Stud welded pins at 600mm for 2000mm board (500mm for 1200mm boards). B Stud welded pins at maximum 100mm (minimum 20mm) from edge of board....

 Open the catalog to page 11

All Promat catalogs and technical brochures

  1. PROMATECT®-XW

    24  Pages

  2. Promat

    30  Pages

  3. PROMASEAL®

    32  Pages

  4. VICUCLAD®

    2  Pages

  5. PROMAFOUR

    6  Pages

  6. MONOLUX®

    2  Pages

  7. FLAMEBRAKER?

    3  Pages

  8. VERMICULUX®

    2  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.