EDUCATION

EDUCATION
1 / 39 PagesView full catalog

EDUCATION

Product catalog summary
Overview: The document emphasizes the significance of well-designed lighting solutions in educational institutions, highlighting how lighting can enhance learning environments. PROLICHT offers customizable LED lighting solutions that are energy-efficient and improve light quality in various educational settings.
Key Sections:
1. Kindergarten: Lighting should create a stable and comfortable atmosphere. Recommended products include DICE, SUPER-G, and GLORIOUS, customizable in 25 colors. Key requirements: minimum illuminance of 300 Lux, uniformity of 0.4, and glare control (UGR ≤ 22).
2. Classroom: Lighting should support different teaching methods and enhance concentration. Recommended products: MAGIQ, SUPER-G, and HYPRO. Requirements: 300 Lux for day schools, 500 Lux for evening schools, with specific lighting for boards.
3. Faculty Room: Requires lighting for work and relaxation. Recommended products: HYPRO and IDAHO. Requirements: 500 Lux for workspaces, reduced glare for computer use (UGR ≤ 19).
4. Library: Needs a pleasant atmosphere with direct and indirect lighting. Recommended products: SIGN and HYPRO-X. Requirements: 500 Lux for reading areas, 200 Lux for bookshelves.
5. Lecture Hall: Requires flexible lighting for various presentations. Recommended products: 2LOOK4 and MAGIQ PRO. Requirements: minimum 500 Lux, specific lighting for speakers' desks and boards.
6. Assembly Hall: Multi-purpose spaces needing flexible lighting. Recommended products: GLORIOUS and MAGIQ PRO. Requirements: 200 Lux with systems for various atmospheres.
7. Corridors: Serve as waiting and meeting areas, requiring safe lighting. Recommended products: NEVERENDING and ONLY LIGHT. Requirements: minimum 100 Lux, presence and daylight sensors for energy efficiency.
8. Break Room: Needs lighting for relaxation and flexible use. Recommended products: SNOOKER and SIGN. Requirements: 200 Lux with warm light colors.
Conclusion: Tailored lighting solutions enhance learning, safety, and comfort. PROLICHT's products efficiently meet diverse requirements.
Introduction: PROLICHT provides specialized lighting solutions for sports halls, focusing on perfect illuminance, homogeneous light distribution, glare control, and good color rendering. Product families include HYPRO, GROOVE, and OIKO.
Product Recommendations: Key specifications: illuminance of 300 Lux, uniformity (Uo) of 0.6, glare control (UGR ≤ 22). Products are ball impact resistant, shockproof, and offer good color rendering (CRI > 80) with neutral white light colors.
Requirements & Norms: Lighting system planning is based on EN 12464-1 standards.
Classroom Lighting Calculations: Various scenarios analyzed, ensuring optimal lighting conditions.
Special Solutions: Custom lighting solutions for unique project requirements, developed in consultation with customers.
Light & Acoustics: Collaboration with IMPACT ACOUSTIC to develop acoustic lights reducing noise pollution while providing ideal lighting.
Guidance Systems & System Integration: Intelligent control systems for easy operation and increased energy efficiency. NATURAL DIM technology and TUNABLE WHITE function allow dynamic lighting adjustments.
Color Customization: A palette of 25 unique colors for luminaires, allowing endless customization options.
Conclusion: PROLICHT is a reliable partner in creating spaces that combine design, function, and social considerations, supporting creative visions in public spaces.
See more

Catalog excerpts

EDUCATION-2

"There is only one thing in the long run more expensive than education: no education." John F. Kennedy

 Open the catalog to page 2
EDUCATION-3

EDUCATION MAKES A DIFFERENCE PUBLIC. Educational institutions play a particularly important role in our society: as places of learning, research and community, they shape us from childhood. Science & Education From elementary schools to science institutes, well-thought-out and economical LED lighting can help to improve learning and research environments and thus improve levels of education and knowledge. PROLICHT offers individually configurable lighting solutions that impress with energy efficiency as well as the best quality of light. Our products can be used in a sophisticated way to improve...

 Open the catalog to page 3
EDUCATION-4

FACULTY ROOM LECTURE HALL ASSEMBLY HALL BREAK ROOM

 Open the catalog to page 4
EDUCATION-5

YOUR PROJECT MAKES YOUR PRODUCT

 Open the catalog to page 5
EDUCATION-6

REQUIREMENTS & NORMS Planning of the lightning system based on EN 12464-1 PLAY ROOMS Illuminance Glare control CRAFT ROOMS Illuminance Glare control Direct-indirect lighting for an appealing Warm white light colors (3000K) for Kindergartens are adventure spaces that should offer every child the best possible conditions and the best development opportunities. However, since children's ability to perceive only evolves gradually, it is particularly important to create a stable atmosphere in which they can orientate themselves and feel comfortable. Rooms that are used by young children place many...

 Open the catalog to page 6
EDUCATION-7

PHOTO: CHRISTIAN FLATSCHER GLORIOUS | SURFACE MOUNTED

 Open the catalog to page 7
EDUCATION-8

The GLORIOUS lights are available as built-in, surface-mounted and pendant versions available and can be supplied with individu- PHOTO: MARTIN VANDORY PHOTO: ARMIN KUPRIAN PHOTO: ARMIN KUPRIAN PHOTO: ARMIN KUPRIAN GLORIOUS | PENDANT LAMP GLORIOUS | SURFACE - MOUNTED LIGHT

 Open the catalog to page 8
EDUCATION-9

REQUIREMENTS & NORMS Planning of the lighting system based on EN 12464-1 Each form of teaching creates its own demands on the classroom, with the illumination being of great importance. A well thought-out lighting concept makes a decisive contribution to concentrated and efficient learning. Evening school Board / Whiteboard Glare control in all directions - Preferably separately switchable circuits for general lighting, black- With different illuminance levels for different zones within a classroom, the attention of the students is increased and an optimal learning environment is created. PROLICHT...

 Open the catalog to page 9
EDUCATION-10

HYPRO X RICO REFLECTOR In the HYPRO-X system, indirect and direct lighting are sensibly combined. The indirect lighting avoids the formation of shadows and does not create strong contrasts, the direct lighting with the RICO LINE ensures glare-free direct INSPIRATION: SYNA work lighting. HYPRO-X — INSPIRATION CLASSROOM In classrooms, the eye often alternates between near and far, for instance from the desk to the board. If the brightness between these two areas differs too much, the eyes find themselves adjusting frequently and rapidly become tired.

 Open the catalog to page 10
EDUCATION-11

SUPER-G lights are available in two widths (65 and 150 mm) and, as a special highlight, can also be PHOTO: CHRISTIAN FLATSCHER illuminated indirectly. SUPER-G SLIM | PENDANT LAMP

 Open the catalog to page 11
EDUCATION-12

PHOTO: SHANNON McGRATH PHOTO: MARTIN TESSLER OPEN LEARNING IDAHO | PROFIL LIGHTS

 Open the catalog to page 12
EDUCATION-13

FACULTY ROOM REQUIREMENTS & NORMS Planning of the lighting system based on EN 12464-1 • Illuminance of 500 lx for room light Glare reduction for computer works- Well balanced direct-indirectlighting for concentrated work and reading • Teachers' rooms are mostly meeting rooms, workplaces and break rooms in one. Different areas and niches can create the right environment for every purpose and ensure more efficiency in everyday work. In order to do justice to the different scopes of application a lighting solution is required that is suitable for all conditions. Emergency and safety lighting The...

 Open the catalog to page 13
EDUCATION-14

PHOTO: ING.ARCH. LUBOR SLADKÝ PHOTO: ARMIN KUPRIAN PHOTO: TAE-HA JEON FACULTY ROOM HYPRO-X SMALL| PENDANT LAMP GLORIOUS | SURFACE MOUNTED

 Open the catalog to page 14
EDUCATION-15

PHOTO: TAE-HA JEON FACULTY ROOM

 Open the catalog to page 15
EDUCATION-16

REQUIREMENTS & NORMS Planning of the lighting system based on EN 12464-1 iniformity (Uo) 0.6 glare control UGR ≤ 19 Reading area Luminaires with direct and indirect light components create a pleasant and inviting atmosphere and at the same time prevent the risk of glare. Glare reduction for computer works Well balanced direct-indirectlighting for concentrated work and reading • For separate reading or work areas, an individual workstation light is recommended in addition to a uniform general illumination. Accent lighting on shelves/doors to With the PROLICHT product families such as SIGN, IDAHO...

 Open the catalog to page 16
EDUCATION-18

INSPIRATION: SYNA INSPIRATION: VIEWTURE.MEDIA SIGN DIVA DANCER HYPRO-F | FREE-STANDING LUMINAIRE PHOTO: WWW.KÜTTEL.CH PHOTO: WWW.KÜTTEL.CH SUPER- G | PENDANT LAMP

 Open the catalog to page 18
EDUCATION-19

LECTURE HALL REQUIREMENTS & NORMS Planning of the lighting system based on EN 12464-1 Preferably separately switchable circuits (Room light/ Board light / Speaker's desk) • Orientation lighting during lectures (Entrance/Exit, Stairs) • Emergency and safety lighting A flexible, variable lighting solution not only enables individual lighting of the individual areas in a lecture hall or adaptation to the type of lecture, but also harmonious lighting conditions throughout the event, from the introduction to the applause. With the families 2LOOK4, IDAHO, GROOVE, MECHANIQ, OIKO PRO and MAGIQ PRO, PROLICHT...

 Open the catalog to page 19
EDUCATION-20

38 | 39 PHOTO: THOMAS HERMANN INSPIRATION: SYNA LECTURE HALL

 Open the catalog to page 20
EDUCATION-21

ASSEMBLY HALL REQUIREMENTS & NORMS Planning of the lighting system based on EN 12464-1 Illuminance Glare control Different lighting systems and scenarios for an inviting lighting mood and atmosphere • Light management system with time and daylight dependent scenes • Holistic lighting concept with integ- ration of daylight to save energy • As a meeting place, its lighting concept should ideally be equipped for a wide variety of situations and create an environment in which people like to come together and feel comfortable. Emergency and safety lighting With the product families 2LOOK4, IDAHO,...

 Open the catalog to page 21

All PROLICHT catalogs and technical brochures

  1. catalogue10

    900  Pages

  2. RETAIL

    96  Pages

  3. OIKO PRO

    36  Pages

  4. SLIDER

    39  Pages

  5. CODE

    37  Pages

  6. MAGIQ PRO

    28  Pages

  7. SLIDER-F

    4  Pages

  8. CENTRIQ

    24  Pages

  9. MINIMAL TRACK

    126  Pages

  10. HADI

    24  Pages

  11. G-BOARD

    33  Pages

  12. INVADER FAMILY

    25  Pages

  13. PUBLIC

    92  Pages

  14. HOSPITALITY

    88  Pages

  15. HYPRO

    53  Pages

  16. CATALOG 2024

    206  Pages

  17. RESIDENTIAL

    94  Pages

  18. 2LOOK4

    13  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.