video corpo

Manual Hinged Double-Leaf Doors (HDLD)
18Pages

{{requestButtons}}

Catalog excerpts

Manual Hinged Double-Leaf Doors (HDLD) - 1

Hinged Double-Leaf Doors (HDLD)

Open the catalog to page 1
Manual Hinged Double-Leaf Doors (HDLD) - 2

5. Double-leaf hinged doors with attachable door frame ___________________________________________ 5 6. Installation kit _________________________________________________________________________________________ 8 7. Installation of HDLD doors onto a metal door frame ______________________________________________8 8. Installation and connection of the electric heating wire _________________________________________ 9 9. Adjusting the door fittings __________________________________________________________________________ 11 10. Operation and maintenance instructions...

Open the catalog to page 2
Manual Hinged Double-Leaf Doors (HDLD) - 3

After having installed the door, it is important to adjust the leaf! This manual outlines information pertaining to ProfHolod refrigeration doors: main uses, information about the doors, technical specifications and installation instructions. ProfHolod doors are manufactured in full accordance with the drawings and documentation provided by ProfHolod LLC. All comments and suggestions for improving operations should be sent to: Russian Federation 141000, Moscow Region, Shchelkovo, st. Zavodskaya, 2. Tel: +7 (495) 240-83-14 e-mail: info@profholod.com Doors manufactured by ProfHolod are...

Open the catalog to page 3
Manual Hinged Double-Leaf Doors (HDLD) - 4

Figure 1. HDLD fittings: Figure 2. Hardware for HDLD R: 1 - adjustable lifting door hinge, Fermod; 2 - internal handle for emergency opening, MTH; 3 - external handle with built-in lock, MTH; 1 - adjustable metal door hinge; 2 - external rotary handle with built-in lock; 3 - internal rotary handle for emergency opening; 4 - additional shutter for doors over 2400 mm high The keys for the door locks are provided by the manufacturer of the locks, ProfHolod cannot be held responsible for the number of unique keys and locks in each order. The door leaf, including the edges, is made from 0.5 mm...

Open the catalog to page 4
Manual Hinged Double-Leaf Doors (HDLD) - 5

Figure 3. Metal door frame for the HDLD. On the left - without a threshold, on the right - with a threshold The overall dimensions of the metal door frame depend on the dimensions of the opening: • Frame width = width of the opening + 212 mm. • If the clearance height is more than 2800 mm, then the frame width = width of opening + 240 mm. • Frame height = Clearance height + 80 mm + threshold height.

Open the catalog to page 5
Manual Hinged Double-Leaf Doors (HDLD) - 6

Figure 4. HDLD with a metal door frame. On the left - without a threshold, on the right - with a threshold Figure 5. Cross-section A-A. On the left, door leaf thickness is 100 or 120; on the right door leaf thickness is 80 mm

Open the catalog to page 6
Manual Hinged Double-Leaf Doors (HDLD) - 7

Figure 6. Cross-section B-B. On the left without a threshold, on the right with a threshold

Open the catalog to page 7
Manual Hinged Double-Leaf Doors (HDLD) - 8

The metal frame and the door leaf are attached to the wall using a mounting kit (optional). HDLD installation: Figure 7. Assembly unit 1 (cross-section B-B). Fastening the metal overlapping door frame to a sandwich panel. 1 - HDLD door leaf 2 - Wall sandwich panel 3 - Metal frame 4 - Threaded rod М8 5 - Erickson nut 6 - PVC thermal washer with PVC thermal nut 7 - Seal 8 - Comb for hanging PVC tapes 9 - PVC tapes 10 - Tape PPE 3x10 to break the cold bridge Figure 8. Assembly unit 2 (cross-section B-B) - Fastening the metal overlapping door frame to a brick wall. 1 - HDLD door leaf 2 -...

Open the catalog to page 8
Manual Hinged Double-Leaf Doors (HDLD) - 9

• Around the perimeter of the frame, glue the PPE 3x10 sealing tape to break the cold bridge. The edge of the tape should line up with the inner edge of the frame. • If necessary, on the reverse side of the frame, at the point where the rubber seal is fitted, fix the wire using adhesive foil. • Secure the frame to the opening using the appropriate mounting kit. • Before the final tightening of the fastening nuts, check the level of the frame on both the vertical and horizontal planes • Hang the leaf on the hinges and tighten the fastening elements. • Fix the decorative plugs over the holes...

Open the catalog to page 9
Manual Hinged Double-Leaf Doors (HDLD) - 10

3. At the threshold of the doorway. The preparation and connecting of the 40 W/m metal braid wire should be carried out in the following sequence: • Cut the braid wire at the required length (no more than 300 mm). • Pull the cable out of the sheath and twist it into a bundle. • Remove the rubber insulation. • Cut off the visible section of the nichrome thread. • Insulate the cable with PVC tape or heat shrinking tubing at the end of the rubber insulation. • Strip the ends of the power supply wires. • Mount the electrical connection box to the wall for the wire. The power supply point for...

Open the catalog to page 10
Manual Hinged Double-Leaf Doors (HDLD) - 11

Figure 11. Assembly unit 3. Wire installation 1 - The metal frame 2 - Door leaf 3 - Double rubber seal (Fermod 67) 4 - Wire, metal braid, of constant power 40 W/m 5 - Adhesive foil tape 6 - PEE 3x10 tape to break the cold bridge 7 - Silicone sealant • The connection is made using a connector block with an AE or VA circuit breaker, with a fuse up to 6 A. Protect the connection point from moisture and dust. ATTENTION! The heating element must be wired by a professional electrician. 8. ADJUSTING THE DOOR FITTINGS HDLD with FERMOD and МТН hardware Adjusting the position of the side hinges...

Open the catalog to page 11
Manual Hinged Double-Leaf Doors (HDLD) - 12

Adjusting the pressure of the lower seal for doors without a threshold should be carried out in the following order: 1. Remove the covers from the half hinges 2. Remove the sheeting from the hinges. 3. Screw the plastic nut clockwise all the way. 4. Hang the door leaf. 5. Unscrew the plastic nut counterclockwise until there is no gap between the lower seal and the floor. To avoid the door hinge being in the way, it is recommended to carry out the adjustment with the door leaf removed or raised. 6. Replace the half-hinge covers. Adjusting the seal pressure from the lock side should be...

Open the catalog to page 12
Manual Hinged Double-Leaf Doors (HDLD) - 13

Adjusting the position of the leaf relative to the opening should be carried out in the following order: 1. Remove the covers from the half hinges. 2. Mark, with a pencil, the position of the half loop on the leaf. 3. Remove the sheeting from the hinges. 4. Loosen the 4 screws securing the half-loop onto the leaf. 5. Move the half loop in the desired direction. 6. Tighten the screws. 7. Hang the door leaf, check the position of the leaf relative to the opening. 8. Replace the half-hinge covers. • Adjustmenting the pressure of the lower gasket for non-threshold doors should be carried out in...

Open the catalog to page 13